SMC Corporation of America
Elite Part Number Search
Search Results "PA3210-03-N"

Made to Order: Standard, Body Size: 20A (3/8, Handle-operated Type), Thread Type: N (NPT - Made to Order), Port Size: 03 (3/8), Option: N (Silencer), Semi-standard: Z (Display Units for Product Nameplate & Pressure Gauge: psi)

Hardware failure) Anagenniseos 7-9-P.C. 14342 N. Philadelphia, Athens, Greece Configuration Configuration Pin No. Signal name Pin No. Signal name OFF Power supply for control and input (US1) is not supplied. 1 24 V (Output) 1 24 V (Output) HUNGARY (36) 23 513 000 Green LED is ON.

Remote system status Anagenniseos 7-9-P.C. 14342 N. Philadelphia, Athens, Greece MS Configuration Configuration Pin No. Signal name Pin No. Signal name Red LED is ON. Non-restorable error is detected. (e.g.

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

Flow Range: 21 (20~200 l/min), Thread: N (NPT Thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire)

Flow Range: 21 (20~200 l/min), Thread: N (NPT Thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 11 (10~100 l/min), Thread: N (NPT Thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire)

Flow Range: 11 (10~100 l/min), Thread: N (NPT Thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))

Flow Range: 11 (10~100 l/min), Thread: N (NPT Thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 21 (20~200 l/min), Thread: N (NPT Thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))

Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket:

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: