(Refer to the instruction manual for details on the cleaning.) 10 12000 14000 40 HAW75 15000 18000 20 45 HAW110 Conditions: Air pressure 0.7 MPa, Cooling water temperature 30C Inlet air temperature 50C is saturated air.
Max. 4 2 x 6.6 2 10 62 21 5 105 2 52 OUT SIG IN OUT SIG 3 x Rc1/4 60 IL211 14.5 Panel fitting dimension 58 45 Panel 35 Max. 4 2 x 6.6 2 52 10 137 62 31 21 5 SIG OUT IN1 OUT1 SIG 2 IN2 OUT2 OUT 5 x Rc1/4 60 IL220 14.5 Panel fitting dimension 2 x 6.6 45 58 Panel 35 Max. 4 2 18 57 10 130 2 OUT IN1 SIG 30 15 4 x Rc1/4 IN2 60 58
Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature.
Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
Coefficient factors Inlet air temperature (oC) 5 to 25 30 35 40 45 50 55 60 65 1.42 1.15 1.00 0.71 0.62 0.50 0.40 0.33 0.21 Inlet air pressure (MPa) 0.3 0.4 0.5 0.6 0.7 to 1.6 0.71 0.75 0.82 0.89 1.00 Ambient temperature (oC) 2 to 25 30 35 40 45 1.0 0.85 0.80 0.73 0.62 Calculation example: The air flow capacity when the dew point of IDFA60 is set to 10 oC under the following conditions <
45 45 IDFA100F150F 2 1 2.1 IDX-OM-U022 2. 2.2 2.2.1 (1) (85%) () B C 245050 () 2000m ) (2) IDFA100F150F 2 2 2.2 IDX-OM-U022 2. 2.2.2 P.6-3 6.3 IDF-AB501 14 1 1 1 4 5 2 3 1 600mm 600mm 600mm 600mm 600mm 1 IDFA100F150F 2 3 2.2 IDX-OM-U022 2. 2.2.3 60 60 .
(Value in the initial stage) Vibration resistance: No malfunction from test with 45 to 1000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF. (Value in the initial stage) Symbol
45 Fluid passage dia.: P R J K 2 x L H I O 4 x Sa Thread depth Sb G M N A D F Vacuum flow Dust bag When dust bag is mounted E T Suction air Suction air Discharge air B C C U Hose band V Note 1) (mm) A 158 B 70 C 50 D 20 E F 24.5 G 60.5 H 5 I 70 J 60 K 5.5 L 72 M 37 N 2 O 30 P Rc1/4 Q R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185 ZH40--X185 28.5 146.5 M4 x 0.7 10 203 90 64 25 27.2 33.5 196.8
Current output Load impedance Maximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green) 2% F.S. 1 digit (Ambient temperature of 25 3C) Lights up when switch output is turned ON.
Fittings & Tubing Air Cylinders Rotary Actuators 4.5 8 11-MXJ4 Model 11-MXJ6 11-MXJ8 6 M3 x 0.5 Air Double acting 0.15 to 0.7 MPa 1.05 MPa 10 to 60C Bore size (mm) Piping port size Fluid Action Operating pressure Proof pressure Ambient and fluid temperature Suction flow rate L/min (ANR) Size 4 6 8 1 1 1 Operating speed range (Average operating speed) Note) 50 to 500 mm/s (Metal stopper: 50
50 55 60 65 1.42 1.15 1.00 0.71 0.62 0.50 0.40 0.33 0.21 MPa 0.3 0.4 0.5 0.6 0.71.6 0.71 0.75 0.82 0.89 1.00 oC 225 30 35 40 45 1.0 0.85 0.80 0.73 0.62 IDFA6010 350.6MPa35> 360 m 3/h(ANR) 1.00 0.89 0.80 256 m 3/h(ANR) 7.2 GWP (GWP) GWP Regulation (EU) No 517/2014 Regulation EU No 517/2014 (IPCC AR4 ) IPCC AR4 R410A 2,088 2,090 2,088 2,090 R410A 1 IDFA60/70/80/90 Series 7-2 IDX-OM-W094
Bore size 50, 63, 80mm Coordinates with the external stopper and forms the toggle mechanisms. Arm opening angle 30, 45, 60, 90, 105, 120, 135 Switch TURCK/P&F Both TURCK and P&F switches are available. Port thread NPT/G Reduces the effects of impact from unclamping the cylinder. Arm Variation Prevents the infiltration of spatter, dust and other contaminants.
(Value in the initial stage) Vibration resistance: No malfunction occurs on the test with one sweep from 45 to 1000 Hz, to axis and right angle directions of main valve each time when energized and de-energized.
(Value in the initial stage) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF.
6 8 33.5 5.5 15 30 M26 x 1.5 1/8 62 120 M10 x 1.25 26 22 19.5 17 32 12 13 8 45 6 8 37.5 5.5 15 34.5 M26 x 1.5 1/8 64 122 M10 x 1.25 26 24 21 22 41 14 16 11 50 8 10 46.5 7 21.5 42.5 M32 x 2 1/4 88 154 32 M14 x 1.5 (mm) Boss-cut ZZ Bore size (mm) 20 25 32 40 103 107 109 138 10
19.5 8.5 8.5 23 38.6 44 27 19.5 M6 x 1 10 21 +0.030 0 CYP32 8.6 6H9 13 12 14 6 25 8.5 75 39 19 19 39 64.9 73.5 49.5 39 M10 x 1.5 12 20 LD LW MM M N L P PA PB Q QW R T TA TB W WA WB Y Z Model CYP15 5.6 69 M4 x 0.7 6 4.5 67 M5 x 0.8 25 60 105 48 45 23 13 18 69 32 17 2.5 118 CYP32 8.6 115 M6 x 1 8 7.5 90 Rc 1/8 50 100 138 87 79.5 29 17 22 115 46 27 3.5 155 Note 1) These dimension drawings indicate
Actuator operation from host . 40 8.1 CiA 402 drive profile . 40 8.1.1 FSA state . 40 8.1.2 Controlword / Statusword . 41 8.1.3 Control mode . 42 8.2 Parameter setting . 43 8.3 Servo-on and Homing . 44 8.4 Positioning operation (Profile position mode) . 45 9.
Coefficient factors Inlet air temperature (oC) 35 40 45 50 55 60 65 70 75 80 1.58 1.46 1.09 1.00 0.79 0.64 0.55 0.51 0.49 0.47 Inlet air pressure (MPa) 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 to 1.6 0.67 0.79 0.88 0.91 1.00 1.02 1.04 1.09 Ambient temperature (oC) 20 25 30 35 40 45 1.19 1.13 1.06 1.00 0.90 0.77 Calculation example: The air flow capacity when the dew point of IDFC60 is set to 10 oC
I/O monitoring . 45 4.1 Input . 45 4.2 Output . 46 4.3 Input / output detailed information . 47 4.4 Forced output . 48 4.4.1 Forced output conditions . 48 5.
Low Profile 2/3-Port Solenoid Valve RoHS Compact Overall length Valve width Actual size Valve height 2-port 3-port 3-port valve 2-port 3-port Overall length 38 mm/54 mm Approx. 10 mm Valve width/ height 2-port 3-port 10 g/20 g Weight 2-port valve Normally closed Large flow rate 2-port/N.C. 3-port 2-port valve Universal C [dm3/(sbar)] 0.25 0.5 Flow rate [L/min (ANR)] 45*1 90*1 *1 At 0.2 MPa