Hexagon socket head screw M3 x 0.5 x 32 VP300-24-4 M4 x 0.7 x 41 VP500-24-3 M5 x 0.8 x 50 VP700-24-1 Sub-plate gasket VP300-2-1P (Rc 1/8) VP300-2-2P (Rc 1/4) VP500-2-1P (Rc 1/4) VP500-2-2P (Rc 3/8) VP700-2-1P (Rc 3/8) VP700-2-2P (Rc 1/2) Mounting Screw Tightening Torques M3: 0.6 Nm M4: 1.4 Nm M5: 2.9 Nm VP300-17-1 VP344 SF4--50 VP500-17-1 VP544 VP700-17-1 VP744 How to Order Sub-plate VP 00
Rc G F 40 SYA 7 1 Base mounted N NPT NPTF T P, R port thread type Type of actuation Nil Rc 2 position single G F Port size 1 N NPT Symbol Applicable series Nil Port size Without sub-plate NPTF T 2 position double 1 8 01 SYA3000 Port size With sub-plate 2 Symbol Nil Port size Without sub-plate Without sub-plate (Pilot port: Expect RC) 1 4 With sub-plate 02 SYA5000 3 position closed center 00
Option 4, 5 port valve N Symbol Electrical entry Electrical entry position C T U D T Sub-plate Conduit Type of actuation Conduit with terminal Sub-plate Body size: 1/8 standard F Single 1 2 3 4 Piping Valve body Grommet Valve body Double Voltage Port size (Nominal size) DIN terminal 0 Bottom ported 1 3 position (Closed center) 3 position (Exhaust center) Side ported 1 100 VAC, 50/60 Hz 00
A maximum effective area of 670mm² (2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 X 30 X 39) and a 3 port, high-capacity exhaust main regulator (VEX1*00 series).
.: 09 (5/16"), Port Size/Applicable Tube: 00 (Same Dia. Tube)
.: 09 (5/16"), Port Size/Applicable Tube: 00 (Same Dia. Tube)
(mm) 72.9 L1 L2 L3 Manifold part no. 1 2 3 4 5 6 7 8 Stations n Vacuum (V) port ZZA101ZZA102ZZA103ZZA104ZZA105ZZA106ZZA107ZZA10810 20 28 Supply pilot valve 20 30 38 30 40 48 Release valve 40 50 58 50 60 68 60 70 78 57.6 70 80 88 Approx. 3000 80 90 98 9.6 5.8 5 Suction filter 10 12 14 n x 10 M5 both sides common air pressure supply (P) port P P Note 1) The above dimensions are for ZZA103-00
A maximum effective area of 670mm² (2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 X 30 X 39) and a 3 port, high-capacity exhaust main regulator (VEX1*00 series).
.: 11 (3/8"), Port Size/Applicable Tube: 00 (Same Dia. Tube)
Ambient and fluid temperature Contacts Error of scale Hysteresis Repeatability Enclosure Mass Air/Inert gas 1.0 MPa 0.8 MPa 0.1 to 0.7 MPa 5 to 60C (No freezing) 1ab 0.1 MPa 0.05 MPa or less 0.05 MPa Equivalent to IP40 0.15 kg Frequency: 1 cycle/sec Service life: 10 million cycles With indicator light Micro Switch Ratings IS3100 (Gasket piping) IS3000-02 (Rc 1/4 thread) 0 1 0 1 IS3 10 IS3 00
Pad Diameter: 63 (ø63), Pad Form: BM (Bellows Type w/Groove), Pad Material: N (NBR, Black), Mounting: C (Metric, Female Thread, M8), Ejector/Nozzle Size: 00 (w/o Ejector)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve only)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102
The area between bold lines in the below graphic shows the relation between load mass and maximum speed. 6 10 Bore size (mm) Operating piston speed (m/s) Allowable kinetic energy (J) 0.012 0.05 to 0.5 0.035 6 L 100 100 5st 10st 15st W 80 10 Load mass W (g) 10 6 60 Load mass (kg) L 1 40 W 20 0.1 00 5 10 15 20 0.01 0.01 1.0 0.1 Eccentric distance L (mm) Maximum speed (m/s) Allowable Eccentric
min (16 L type) [ 20.0] 20.0 L/min (40 L type) [ 50] 50 L/min (100 L type) [ 126] 126 L/min (250 L type) [ P_2] Set value (OUT2) [F 2]/[ oUt2] Page 41 5% of maximum rated flow [ 0.20] 0.20 L/min (4 L type) [ 0.8] 0.8 L/min (16 L type) [ 2.0] 2.0 L/min (40 L type) [ 5] 5 L/min (100 L type) [ 12] 12 L/min (250 L type) [ H_2] Hysteresis (OUT2) [F 3]/[ RES] [ rES] Response time setting [ 1 .00
Piping Specification: 00 (ZM Ejector Mounting), Output Specification: 18 (NPN Open Collector 1 Output, w/Analog Output, 3 Rotation setting), Wiring Specification: CL (Plug Connector; Lead Wire 3.0m)
Piping Specification: 00 (ZM Ejector Mounting), Output Specification: 18 (NPN Open Collector 1 Output, w/Analog Output, 3 Rotation setting), Wiring Specification: L (Grommet; Lead Wire 3m)
Piping Specification: 00 (ZM Ejector Mounting), Output Specification: 15 (NPN Open Collector 1 Output, w/o Analog Output, 200° Setting), Wiring Specification: C (Plug Connector; Lead Wire 0.6m)