SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-12-DO-00N"

Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 3. Do not use in a place subject to heavy vibration and/or shock. 1. Drain flushing Remove drainage from the air filters regularly. 2. Lubrication Once lubrication has been started, it must be continued.

Do not apply excessive force or shock to the body or fittings with an impact tool. It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below.

It could lead to fire, explosion and corrosion. (12) Do not apply radiant heat from a large heat source such as direct sunlight or heat treatment furnace. It will cause failure of the controller or its peripheral devices. (13) Do not use the product in an environment subject to a temperature cycle.

Do not obstruct the exhaust port of the ejector. Do not cover the exhaust port. Otherwise, vacuum is not generated. Do not block the exhaust port to release the work piece. This can damage the vacuum ejector.

2-wire 12 V Connector Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V 24 V Grommet 2-wire Water resistant (2-color indicator) 12 V F7BAV F7BA With diagnostic output (2-color indicator) IC circuit F79F 4-wire (NPN) 5 V, 12 V 3-wire (NPN equivalent) IC circuit A76H 5 V Grommet A72H A73H A80H A72 A73 A80 A73C A80C 200 V 100 V 12

OUT1 12 to 24 VDC 12 to 24 VDC Load Load Load White OUT2 White OUT2 Load Blue DC () Blue DC () -R: NPN (2 outputs) + Auto-shift input -S: NPN (2 outputs) + Auto-shift input -T: PNP (2 outputs) + Auto-shift input -V: PNP (2 outputs) + Auto-shift input Brown DC (+) Brown DC (+) Load Gray Auto-shift input Gray Auto-shift input Load + + Black OUT1 Black OUT1 12 to 24 VDC 12 to 24 VDC Load

Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product for flammable or highly permeable fluids. Fire, explosion, breakage or corrosion can result. Do not Do not use the product in a place where static electricity is a problem.

Disassembly Do not disassemble for purposes other than the main valve replacement, or malfunction may occur. Refer to the Disassembly/Assembly Procedure on page 12 for the replacement of the main valve. 1. Operate under conditions that are free of vibration and impact. 2. Operate in an ambient temperature range between 0C and 50C. 3.

V IC circuit Reed auto switch Solid state auto switch 12 V Diagnostic indication (2-color display) 5 V,12 V IC circuit Relay, PLC Grommet 24 V Yes 12 V 5 V,12 V IC circuit Water-resistant (2-color display) M9PAV1 M9BAV1 12 V Magnetic field resistant (2-color display) 2-wire (Non-polar) 3-wire (NPN equivalent) A96V A96 5 V IC circuit Yes 24 V Grommet A93V2 A90V A93 A90 12 V 5 V

Transporting using casters 1) This product is heavy and should be moved by at least two persons. 2) Do not grip the piping port on the right side or the handles of the panel. 3) When transporting using a forklift, be sure not to let it hit the casters or adjusters, and drive the fork all the way through until it comes out the other side. 4) Do not get across steps with casters. 2.

We do not guarantee against any damage if the product is used outside of the specifications range. (2) Do not disassemble the product or make any modifications, including additional machining.

Mounting, Operation P.12 1) Operating air P.12 2) Precaution on design P.12 3) Mounting P.14 4) Operating environment P.15 5) Piping P.16 6) Cushion P.17 7) Speed control P.18 8) Direction control P.19 4. Maintenance P.20 1) Inspection P.20 2) Overhaul P.21 3) Disassembly P.22 4) Assembly P.23 5) Expendable supplies P.24 6) Replacement procedure of seal P.25 7) Inspection P.26 5.

point RC (Left arm) RA (Dual arm) RB (Right arm) PD0.05 PB0.02 LA0.1 LB L PA0.02 PC0.05 N 2 x 2-PH7 Depth D 2 x 2 x NPT 1/4 G 2 x 2 x MM Depth J E B RD (mm) Bore (mm) B C D E GA GB GC J L LA LB MM N P 50 63 80 12 15 12 95 112 154 48 54 76 13.7 16.6 19.6 134.3 141.2 185.8 138.5 147.5 199 93 90.5 137.5 12 12 18 376.7 395.6 530.9 149.5 158.5 214 78.4 78 113.7 19 22 30 8 10 12 M8 x 1.25 M10

(Do not change.) Pin 3 Reserved. (Do not change.) OFF Pin 4 Reserved. (Do not change.) OFF When using the MECHATROLINK-III standard servo profile, set the number of transmission bytes to either 32 or 48. When using the MECHATROLINK-II-compatible profile, set the number of transmission bytes to either 16 or 32.

Nylon tube Within 0.1mm Soft nylon tube Within 0.1mm Polyurethane tube Within+0.15mm, Within -0.2mm Do not use tube which do not meet these outside diameter tolerances.

The received message is deleted if the calculation result and received CRC do not match.

Retaining rings are included. 8 25 14 Type C 5 Type C 5 6.4 12 1.5 0.7 1.5 0.7 5 5 5 4.8 4.8 M5 x 0.8 22.7 18.3 16.6 12.2 Double Knuckle Joint Mounting Nut Rod End Nut d d MM L ND hole H10 Shaft d9 R1 12 C C + 0.2 0 + 0.2 0 A1 L1 NX U1 12 7 B H B H Knuckle pin and retaining ring are packaged together.

PA03 02: LEC-MR-RB-032 03: LEC-MR-RB-12 Set this parameter to enable the absolute position detection system. For details, refer to "LECSN-T Operation Manual, Chapter 12.

Do not use in direct sunlight. 3. Do not operate in a location subject to vibration or impact. 4. Do not mount the product in locations where it is exposed to radiant heat. 5. Do not use this product in an area that is dusty, or in an environment in which water or oil splashes on the cylinder. 3-7. Lubrication Caution 1.

PV SV 12. Select contact input signal 2 from the table below with [] key or [] key, and confirm by pressing SEL.