SMC Corporation of America
Elite Part Number Search
Search Results "VY1200-200-G"

Reference: Bureau of Industry and Security (USA) http://www.bis.doc.gov/ 1) 2B350.g.2 (1) Product name : Regulator, Diaphragm valve (2) Body material : Hastelloy (3) Connection size : 1/2 inch or more 2) 2B999.g (1) Product name : Regulator, Back pressure regulator, Diaphragm valve, Check valve, Vacuum generator module (integrated with valve

A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV

Series 10-MGF Guide table 40, 63, 100 How to Order 10 M G F 63 50 Y59B Number of auto switches 2 pcs. 1 pc. 10 Clean series Relief type Nil S Bore size (mm) Reed switch Type of auto switch Port type Z73 Solid state switch Y59A,Y59B Bore size Type Rc NPT G Symbol Nil TN TF 40, 63, 100 Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action

Free flow Controlled flow Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Model Port size Weight (g) AS420-02 2,500 1/4 38 3,600 55 0.34 AS420-03 5,000 3/8 77 4,800 74 0.33 63, 80, 100, 125 AS420-04 6,600 1/2 100 6,700 102 0.32 AS500-06 10,100 3/4 154 8,100 123 140, 160, 180, 200 0.36 AS600-10 15,100 1 230 16,900 258

Thread type Rc NPT G Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model 1000 (35) 200 (7) 500 (17.5) Max. flow capacity l/min (ANR)(SCFM) 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 (2.54) 0.43 (0.95) 0.68 (1.50) Weight kg (lb) Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less (14.5 psi

Thread type Rc NPT G Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model Maximum flow capacity l/min (ANR) 1000 200 500 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 0.43 0.68 Weight kg Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less Ambient and fluid temperature 5 to 50C Filtration degree

. 30 10, 20, 30, 40, 50, 75, 100 40 10, 20, 30, 40, 50, 75, 100 Bore size Strokes are available in 1 mm increments by installing spacers in standard stroke cylinders. 10 16 20 25 30 40 10 mm 16 mm 20 mm 25 mm 30 mm 40 mm Port thread type M thread Rc NPT G 10 to 20 Nil 25 to 40 TN TF Series MQQ is not auto switch capable.

Mounting bracket B L F G C Basic type Axial foot type Front flange type Rear flange type Single clevis type Without auto switch Nil Auto switch type Select applicable auto switches from the table below.

Pin Clamp Cylinder Lock mechanism Clamp arm Series CKQ/CLKQ 50 Work Work LOCK Feature 1 Pin Clamp Cylinder 50 Series CKQ/CLKQ How to Order Port thread type Guide pin shapes Nil TN TF Bore size Rc NPT G R D Round Diamond 50 50 mm The diamond shape is for pin diameter of 17.5 or over.

EXH (pilot air exhaust port) FLUID IN 1/2, 3/4 1/4 5 Series PA3000/5000 Process Pump Air Operated Type (External Switching Type) How to Order 1 1 PA 3 03 3 PA3000 Body size Connection port size 03 04 06 3 5 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 3/8 standard 1/2 standard Liquid contact body material Thread type 1 2 ADC12 (aluminum) SCS14 (stainless steel) PA5000 Nil T F N Rc NPTF G

Internal Switching Type) Series PA3000/5000 How to Order 1 1 PA 3 03 0 PA3000 Option Body size Nil N Body only With silencer 3 5 3/8 standard 1/2 standard For AIR EXH: AN200-02 Liquid contact body material Connection port size 03 04 06 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 1 2 ADC12 (aluminum) SCS14 (stainless steel) PA5000 Diaphragm material Thread type 1 2 PTFE NBR Nil T Rc NPTF G

Model g (oz) ZFA100 50 (1.75) 1/8 140 (4.94) High flow rate square type ZFA200 200 (7) 1/4 190 (6.71) ZFB10 10 to 20 (0.35 to 0.7) 4, 6, 3/16", 1/4" 22 (0.78) ZFB20 30 to 50 (1.05 to 1.75) 6, 8, 1/4" 30 (1.06) Universal type ZFB30 75 (2.63) 10, 3/8" 40 (1.41) ZFB401 100 (3.5) 1/2" 62 (2.19) ZFA100 Specifications Air, Nitrogen Fluid Negative pressure Operating pressure 0.5MPa (72.5psi) Withstand

Pipe thread type Nil Rc F G (With Rc-G conversion tting set) N NPT (With Rc-NPT conversion tting set) Power supply Single-phase 200 to 230 VAC (50/60 Hz) 9 A

Pipe thread type Nil Rc F G (With Rc-G conversion tting set) N NPT (With Rc-NPT conversion tting set) Power supply Single-phase 200 to 230 VAC (50/60 Hz) 9 A

Internal Switching Type) Series PA3000/5000 How to Order 1 1 PA 3 03 0 PA3000 Option Body size Nil N Body only With silencer 3 5 3/8 standard 1/2 standard For AIR EXH: AN200-02 Liquid contact body material Connection port size 03 04 06 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 1 2 ADC12 (aluminum) SCS14 (stainless steel) PA5000 Diaphragm material Thread type 1 2 PTFE NBR Nil T Rc NPTF G

Lube unit S1 Thread type 1a (without oil OFF) ALDU600 (with panel) S2 Rc NPT Nil Body size (Standard) N 6 9 1B 2B Accessory Port size Symbol Description Nil Bracket Panel Float Switch Specifications 4 3 06 10 12 14 20 1 1 1 Voltage Max. cut off capacity Max. cut off current Contact point construction Level indication 200 VAC, 200 VDC 12 VAC, 10 W DC 0.6 A AC, 0.5 A DC 1a, 1b Bottom limit

Model g (oz) ZFA100 50 (1.75) 1/8 140 (4.94) High flow rate square type ZFA200 200 (7) 1/4 190 (6.71) ZFB10 10 to 20 (0.35 to 0.7) 4, 6, 3/16", 1/4" 22 (0.78) ZFB20 30 to 50 (1.05 to 1.75) 6, 8, 1/4" 30 (1.06) Universal type ZFB30 75 (2.63) 10, 3/8" 40 (1.41) ZFB401 100 (3.5) 1/2" 62 (2.19) ZFA100 Specifications Air, Nitrogen Fluid Negative pressure Operating pressure 0.5MPa (72.5psi) Withstand

HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H

VAC (50 Hz) 200 to 220 VAC (60 Hz) Single phase 220 VAC (50 Hz) 0 F G N NPT 1 5 6 134 Heatless Air Dryer ID Series Working Principle Flow Rate Inlet pressure: 0.7 MPa Pressure drop (MPa) HAA HAW The compressed air that flowed in from the IN side passes through the 4 port solenoid valve, and after it is dehumidified at adsorption cylinder T1, it turns into dry air and exits from the OUT side

Operating time Power source 50 60 100, 200 VAC Hz, Other 4 W Power consumption OUT: 3 8 IN: 3 8, 1 2 Port size Weight 550 g If the operating cycle is twice in a minute (operating time 2 sec. x 2) operating time is 4 sec. each minute. Specific Product Precautions Low power consumption: 4 W A long pipe can also be connected to the discharge port.