SMC Corporation of America
Elite Part Number Search
Search Results "ZZK206A-A1S0-D-A"

www.stevenengineering.com I 6.11 VACUUM VACUUM PADS SERIES ZP H O W T O O R D E R ZPT P A D V E R T I C A L T Y P E W I T H O U T B U F F E R ZPT V A C U U M E N T R Y ( A L S O M O U N T I N G T H R E A D D I A) P A D D I A M E T E R S Y M B O L T H R E A D D I A M E T E R 2~ 8 10~ 16 20~ 32 40 50 02 2 04 4 06 6 08 8 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 P A D M AT E R I A L Male

Example) XLA-25H0-2M9NJLA-XAN1A 18 XLm Series Dimensions XLA/F (With D-M9mJm) C E E C E Fn D Heat-resistant auto switch H B A Heater G A [mm] Series Valve size A B C D E Fn G H 25 50 121 48 27 12 40 26 44 40 65 171 66 39 11 55 41 67 50 70 185 79 46 11 75 52 72 XLA XLF XLC/G25, 40 (With D-M9mJm) XLC/G50 (With D-M9mJm) C E C E E C E E C E Fn B A Fn D D Heat-resistant auto switch H J K H B A

(mm) Effective area (mm2) Nylon Urethane 13.4 25.6 40 Note) Weight (g) Model D M2 L Q M1 M2 D Applicable tubing a a b KQ2TX06-08 KQ2TX08-10 KQ2TX10-12 13 27 36 6 8 10 8 10 12 10.6 17.7 28.4 15.2 18.5 20.9 18.5 21 22 Note) D: Max. diameter 23 26.5 28.5 11.1 12.8 13.9 17 18.5 21 M1 D Applicable tubing Applicable tubing 2-8 2-4.2 Applicable tubing a 15-2-23 15 Series KQ2 Different Diameter Cross

Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7

B B A REC A dimension B dimension Auto switch model CX D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F CY D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area

D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NTL D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW A B A B A B A B A B A B A B A B A B A B 32 13.5 10.5 9.5 6.5 10 7 15 12 3.5 0.5 7.5 4.5 3.5 0.5 7 4 9 6 6.5 3.5 40 10.5 14 6.5 10 7 10.5 12 15.5 0.5 4 4.5 8 0.5 4 4 7.5 6 9.5 3.5 7 50 13 14.5 9 10.5 9.5 11 14.5 16 3 4.5 7 8.5 3 4.5 6.5 8 8.5 10 6 7.5 63 13 15.5 9 11.5 9.5 12 14.5 17 3 5.5 7

B D A A B D B D Dimensions Dimensions Dimensions (mm) (mm) (mm) A B C D E F Y A B C D E F G Y A B C D E F Y Model Model Model ZP40HB ZP63HB ZP100HB 40 41.4 28.4 43.2 20.5 30 13 63 65.1 45.5 67.6 31.5 50 4.5 21.5 100 103.1 68.6 106.7 47.5 80 35.5 ZP50HB ZP80HB ZP125HB 50 51.9 35.7 54 24 40.5 16.5 80 83 58.4 85.1 37 64 5 27.5 125 128.5 88.6 135 56 44 105 13-11-95 Series ZPT/ZPX How to Distinguish

NCDQ8A(B)-(C)(M) (in) NCDQ8A(B)-100T(M) (025st to 100st) (in) D-A9, D-A9V Bore size D-M9(V), D-F9W(V) D-A9, D-A9V D-M9(V), D-F9W(V) D-F9BAL D-F9BAL Bore size A B HS A B HS A B HS A B HS A B HS A B HS 056 075 106 150 200 250 056 075 106 150 200 250 0.61 0.55 0.85 0.83 0.81 0.98 0.04 0.08 0.12 0.12 0.2 0.28 0.71 0.81 0.96 1.18 1.45 1.6 0.77 0.71 1 0.98 0.96 1.14 0.2 0.24 0.28 0.28 0.35 0.43

(A contact) F9N F9P F9G F9H F9GL F9HL F9B F9NL F9PL F9BL D-F9N D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL Slide screw Lead screw type N.O. (A contact) N.C. (B contact) S N.C. (B contact) Lead screw lead N.C. (B contact) A B 6mm 12mm N.C. (B contact) N.O. (A contact) N.O. (A contact) Stroke N.O.

D-G5NT D-G5lW D-K59W D-G5BA D-G59F D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-B5l D-B64 D-A9l D-A9lV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5

. (20 stations maximum) When a longer DIN rail is desired than the specified stations, specify the station number to be required. (20 stations maximum) Terminal block mounting position Symbol Mounting position Symbol Mounting position U U side U U side A, B port size (Metric size) A, B port size (Metric size) D D side D D side Valve stations Valve stations Symbol Port size Applicable series

1 Drain Port 3/4 3/4, 1 D I M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT

D-H7NF Auto switch D-A3A D-G39A D-K39A D-A44A D-C7 D-C80 D-C73C D-C80C D-A3A D-G39A D-K39A D-A44A model Data D-C73C D-C80C D-B5 D-B6 D-B59W D-G5NTL Bore size A 1() 1() 2(0) 7 B 0() 0() 0.5(0) 5.5 A 6(4) 6(4) 7(5) 12 B B 0() 0() 1(0) 6 B 5(3) 5(3) 6(4) 11 Hs 22.5 25 28.5 32.5 A 7(5) 7(5) 8(6) 13 A Hs 25 27.5 31 35 B 6(4) 6(4) 7(5) 12 Hs 60 62.5 66 70 A 4(2) 4(2) 5(3) 10 Hs 69.5 72 75.5 79.5

D-X 571 B RSQ Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V 12 Hs B B A B B A 16, 20 B A Hs B Hs B A Hs B A Hs B A 32 to 50 A A B A A B A Hs D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-F7BA D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V D-F7BAV 16, 20 B A Hs B A Hs

Hs D-A44 A A 49.5 Auto switch 376 Auto Switch Mounting CH2E/CH2F/CH2H Series Auto Switch Proper Mounting Positions CHQ D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F59F/F5BA Note2) D-A9/A9V Bore size (mm) D-G39/K39 D-A5/A6 D-B5/B64 D-A3/A44 D-F5NT D-A59W D-B59W CHK CHN A A A A A A A A A A A 32 25 21.5 26.5 17 15 19 15.5 18.5 CHM 40 26 22.5

D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length. 2 Please contact SMC when using built-in contact protection circuit style (DA34[A][C], D-A44[A][C], D-A54/A64, D-B54/B64, D-A59W, D-B59W) in the following conditions: 1. The wiring length to load is more than 30 m; 2. When using PLC with large flow current.

D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length. 2 Please contact SMC when using built-in contact protection circuit style (DA34[A][C], D-A44[A][C], D-A54/A64, D-B54/B64, D-A59W, D-B59W) in the following conditions: 1. The wiring length to load is more than 30 m; 2. When using PLC with large flow current.

D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV ( ) MY1CW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 63 50 40 32 25 Mounting position 40 32 25 Mounting position 25 Mounting position 32 40 50 63 A 323.5 278.5 157.5 127.5 97.5 157.5 127.5 97.5 97.5 127.5 157.5 278.5 323.5 A A B 136.5 121.5

Hs Auto switch Auto switch Ht Ht A B A B D-Z7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV/Y7BAL D-P5DWL Hs A Auto switch Hs Ht Ht Ht B B A 32 6-6-12 12 Series MB Air Cylinder: Standard Type Double Acting, Single Rod Auto Switch Mounting Position/Mounting Height Auto Switch Mounting Position (mm) D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39

Its Mounting Height A Hs Series C85 Series CP96 Series C96 Series C55 Auto switch Ht B Auto Switch Proper Mounting Position (mm) D-Z7 D-Z80 D-Y59 D-Y69 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BA Auto switch model D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-F5W D-J59W D-F5 D-J5 D-F5BA D-F59F D-A3 D-A44 D-G39 D-K39 D-A9 D-A9V D-A5 D-A6 D-P4DW D-F5NT D-A59W A B A B A B A B A B A B A B A B A B Bore size