Stations: 2 Stations, Port Size: 02 (Rc1/4), Electrical Entry Direction: D (Plug-in L Kit D Side), Cable Length: 2 (3.0m Cable)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: YO [DIN Terminal w/o Connector (DIN 43650C)], Lead Wire Length: None, Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (Base
Body Size: 25, Thread: N (NPT), Port: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)
Function: 2 (2 Position Double), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4, Side Piping)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: E (Push-turn Locking Lever Style), Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF)
Configuration: 2 (2 Position Double), Sealant: 1 (Rubber Seal), Function: Standard (1W), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, 1: 1, Porting Specification: B (Bottom Ported), Port Size: 02 (1/4)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 2 (200VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: N (NPT)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 12J (1 + 2 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Stations: 3 Stations, Port Size: 02 (Rc1/4), Electrical Entry Direction: D (Plug-in L Kit D Side), Cable Length: 2 (3.0m Cable), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: None, Option 2: W (IP65 Protection Compatible)
Body Size: 20A, Thread: N (NPT), Port Size: 02 (1/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 02 (Base Mounted w/Sub-plate 1/4), Thread
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 02 (Rc1/4)
Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port: 02 (1/4), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4), Thread: F (G)
Body Size: 20, Thread: Rc, Port: 02 (1/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Standard