Model: 10S (Side Ported), SI Unit Specification: ZE (EtherNet/IPâ„¢), Input Block Stations: 4 Stations, Input Block Type, Common Spec: B (Positive Common, M12, 4 Inputs), Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: U (Port Location U Side, Internal Pilot), A, B Port Size: C8 (ø8 One-touch Fitting)
Model: 10S (Side Ported), SI Unit Specification: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Ouput Polarity: N (Negative Common, PNP), Valve Stations: 6 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C8 (ø8 One-touch Fitting, Straight, Metric)
Model: 10S (Side Ported), SI Unit Specification: 0 (w/o SI Unit), SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 2 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting, Straight, Metric)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: Q (DeviceNetâ„¢, Negative Common), Input Block Stations: None, Input Block Type: A (PNP Sensor Input, M12, 2 Inputs), Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: U (Internal Pilot, U Side, 2 to 10 Stations), A,B Port Size: C8 (ø8 One-touch Fitting)
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: A (2 NPN Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R
Model: 10T (Side Ported), Type: C (Spring Type), Valve Stations: 11 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 6 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C8 (ø8 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 6 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C8 (ø8 One-touch Fitting)
Model: 10T (Side Ported), Type: None, Valve Stations: 11 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit Specification: EB (EtherNet/IPâ„¢, IO-Link Units), SI Unit Output Polarity, End Plate: 5 (SI Unit Negative Common, 7/8" Connector), I/O Unit Stations: None, Valve Stations: 10 Stations, P,E Port, SUP/EXH Block: U (U Side, 2 to 10 Stations, Internal Pilot), A,B Port Size: C8 (ø8 One-touch Fitting, Straight, Metric)
Type: 10S (Side Ported), SI Unit Specification: VB (CC-Link - 16 Outputs - Connector M12), SI Unit Output Polarity: N (Negative Common), Valve Stations: 6 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: C8 (8mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only), Bracket: None, Operation Manual/Calibration Certificate: K (with Operation Manual and Calibration
Stations: 5 Stations, Port Size: C8 (ø8 One-touch Fitting), Thread Type: Rc, Option: S (Built-in Silencer, Direct Exhaust)
Model: 10S6 (Side Ported), SI Unit: EB (EtherNet/IPâ„¢, IO-Link Unit), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C8 (ø8 One-touch Fitting)
Model: 10S (Side Ported), SI Unit Specification: ZE (EtherNet/IPâ„¢), Input Block Stations: 8 Stations, Input Block Type, Common Spec: F (Negative Common, M8, 4 Inputs), Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: C8 (ø8 One-touch Fitting)
Type: 10S (Side Ported), SI Unit Specification: FA (PROFINET - 32 Outputs - Connector M12), SI Unit Output Polarity: N (Negative Common), Valve Stations: 9 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
Stations: 5 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C8 (ø8 One-touch Fitting)
Stations: 9 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: C8 (ø8 One-touch Fitting)