SMC Corporation of America
Elite Part Number Search
Search Results "SY7000-27-2T"

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 27 lb

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 27 lb

Series RLQ is currently available in bore sizes of 32, 40, 50 and 63mm, with standard stroke options between 20 – 100mm.Large allowable kinetic energy, Noise reduction (27% noise reduction compared to CQ2 without cushion), Good stroke repeatability (Metal to metal at stroke end), Manual override mechanism allows unlocking with simple tools, Bypass piping type is available for applications

Series RLQ is currently available in bore sizes of 32, 40, 50 and 63mm, with standard stroke options between 20 – 100mm.Large allowable kinetic energy, Noise reduction (27% noise reduction compared to CQ2 without cushion), Good stroke repeatability (Metal to metal at stroke end), Manual override mechanism allows unlocking with simple tools, Bypass piping type is available for applications

Conforms to ISO 6431, CETOP RP43P, VDMA 24562, Large bore size (160~250mm), Standard strokes up to 2400mm (depending on bore size), Stainless steel rod, Auto switch capable, CYLINDER, TIE ROD (JAPAN), ISO TIE ROD CYLINDER, 285, 27 lb

Mount pressure gauge (ø14mm)., Allow to select one-touch fitting., Adopt backflow function as standard., Regulator Block, Individual Supply Type., REGULATOR BLOCK, REGULATOR, MANIFOLD, FVD, 27 lb

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 27 lb

ZS-46-B Panel mount adapter ZS-46-D Panel mount adapter + Front protection cover ZS-46-5L Power supply/output connection lead wire 5-core, 2 m ZS-27-01 Front protection cover B Panel mount adapter Connection Example ZS-46-B PFG300 Sensor connector D Panel mount adapter + Front protection cover PF3A7 H Power supply/output connection lead wire ZS-46-D Lead wire and M12 connector (Option for

Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation

Double acting Double acting spring type Single acting Contents Roller pin Lever pin Lever spring Magnet Flat washer 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Bore size (mm) 50 63 80 RS2H50D-PS RS2H63D-PS RS2H80D-PS RS2H50T-PS RS2H63T-PS RS2H80T-PS Set of nos. above #7 to $0 (excluding #8) Zinc chromated Type C retaining ring for shaft Seal kit includes #7 to $0 (excluding #8).

Required ventilation rate [m3/min] Heat radiation amount [kW] Differential temp. of 10.8F [6C] between inside and outside of installation HRS100-A-20 Approx. 305 155 HRS150-A-20 Approx. 440 220 Differential temp. of 5.4F [3C] between inside and outside of installation Model 27 Series HRS100/150 Specic Product Precautions 4 Be sure to read

JM-10 JM-800 JM-1000 C 1.299 1.732 2.165 F 1 1/8 1 1/2 1 7/8 H 27/64 35/64 23/32 Dimensions per ASME B18.2.2 1987 (1999) Note: Jam nut is included. 13 Series NCA1 Cylinder Large Bore Series NCA1 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.

resistance value () 7.2 14.4 58 144 7.2 14.4 58 144 7.2 14.4 58 144 Max. operating pressure (MPa) [at 24 VDC] 0.7 0.7 0.7 0.6 0.7 0.7 0.6 0.4 0.7 0.7 0.4 0.25 Ambient and fluid temperature (C) 10 to 50 (No freezing) Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s2) 300/50 Enclosure Dustproof Electrical entry Grommet Weight (g) Screw mount type 27

(mm) 8 6.5 5 4 External layer thickness (mm) 1 1 1 1 Note) Black (B) External layer color White (W) Red (R) Inner tubing Blue (BU) Yellow (Y) Outer layer Green (G) Minimum bending radius (mm) 15 20 27 35 Sectional view of FR double layer tubing Max.

Note 2) Applicable fittings Note 2) 3) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Caution Min. bending radius Min. bending 15 12 23 17 45 34 55 42 65 50 90 70 18 12 27 15 30 23 55 42 65 50 radius mm Note 4) Bending value (Reference) 1. Compatible with water due to a change in materials.

Operating Pressure KC Fluid Air KK 7 20C 1.0 Max operating pressure (MPa) 40C 0.85 KK130 6 60C 0.7 Max. operating pressure (MPa) DM Applicable fittings One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings 5 Min. bending radius (mm) 10 15 20 27 35 KDM Operating temperature 20 to 60C 4 KB Material Polyurethane 3 KR How to Order 2 KA TUH0604 B 20 1 KQG2 0 -20 0 20 KG

VEX3220/3222 Valve mounting surface Pilot port Pilot port Manifold base Port 2(A) side Port 2(A) side Internal pilot Common external pilot + + + + Blanking plate assembly VVEX2-2 (Common external pilot) Exhaust from both ends when there are 5 stations or more. 2 x M5 Common external pilot port (VVEX2-2 only) 2 x Port 3(R): 1/4 30.5 2 x 6.5 7.5 A B A B P1 P1 13.5 (For mounting) 98 88.2 11.5 27

Lead Wire Specications Model D-MP Sheath Outside diameter [mm] 2.6 Insulator Number of cores 4 (Brown/Blue/Black/White) Outside diameter [mm] 0.57 Conductor Effective area [mm2] 0.08 Minimum bending radius [mm] (Reference values) 13 Weight [g] Model D-MP025 D-MP050 D-MP100 D-MP200 Lead wire length 2 m (A) 29 31 37 51 0.3 m (B) 17 19 25 39 0.3 m (C) 25 27 33 47 How to Order D MP 025 A Measuring