The element service indicator is shipped mounted to the micro mist separator with pre-filter, and cannot be retrofitted or used with the single style. 33 Membrane Air Dryer Series IDG Made To Order Specifications Dimensions/With Element Service Indicator (mm) 1in = 25.4mm IDG3M, 5M, 10M, 20M IDG3HM, 5HM, 10HM, 20HM (A) (B) K (D) C L H 37 J IN OUT M F (E) (G) M5 female threads (A) IDG30M,
Model AU ALU ALHU F R Barb fitting M3, M5 M3 M5 Barb elbow Barb one-touch Reducer Removing tubing Withdraw the sleeve straight along the tubing. Use a tool such as long-nose pliers if it is difficult to pull out by hand. 1. Withdraw the tubing straight. 2.
0.05 0.07 0.05 0.07 U W M5 x 0.8 U W 597
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1
(UL standard V-0) Applicable model: ASV310F, ASV410F, ASV510F Inch size Note) Elbow: M3, M5 only Port size AS 04 06 08 10 12 03 07 09 11 13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" M3 M5 U10/32 01 02 03 04 M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 With One-touch fitting Thread type ASP Brass parts are all electroless nickel plated.
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A
Proper tightening torque Body Lock nut width size [ Nm ] across flats Chamfer dimension D[mm] Connection M5 0.17 7 thread size (Recommended value) 1/8 0.3 9 M5 5.1 5.4 1/4 1 12 10-32UNF 5.0 5.3 3/8 1.5 14 1/2 2 17 Piping Threads with Sealant Caution (1) If the fitting is tightened with excessive (5)For R, NPT, G thread torque, a large amount of sealant will seep out.
01 02 03 04 06 M5 x 0.8 AQ1500 AQ1510/2000 AQ2000/3000 AQ3000 1 8 1 8 Standard 1 4 0 1 M5 x 0.8 8 3 1 2 Note) AQ150 only AQ5000 3 4 Thread type Metric thread (M5) Rc NPT G Nil N F 554 Quick Exhaust Valve Series AQ Construction Specific Product Precautions AQ1500/1510 AQ2000/3000/5000 Be sure to read before handling.
Finger Air Gripper Dimensions (mm) 1in = 25.4mm MHS2-50D, 63D 4-5.1, counter bore dia. 9.5 Counter bore depth SC (mounting hole) RA AA 6.4 AB AC 35 35 RA 5 VA, depth VB YC RB RB NA B XA, depth XB NB Q 4-M6 x 1, thread depth 12 (mounting threads) O 20 20 FX FY FZ (Open DO) (Closed DC) WA, depth WB 4-M5 x 0.8, thread depth 10 Attachment mounting threads CB CA M5 x 0.8 (finger opening port)
Model AU ALU ALHU F R Barb fitting M3, M5 M3 M5 Barb elbow Barb one-touch Reducer Removing tubing Withdraw the sleeve straight along the tubing. Use a tool such as long-nose pliers if it is difficult to pull out by hand. 1. Withdraw the tubing straight. 2.
A Connections: TW Connections: TW 1.0 (25.4) 1.0 (25.4) 45 45 AP SL M5 x 0.8 depth 0.25 (6.4) (Mounting hole) M5 x 0.8 depth 0.25 (6.4) (Mounting hole) AZ AZ AK Note) MV6 is bar stock body.
Normal condition: Flow display which is converted in atmospheric pressure at 0 C. 5: Total accuracy when used with applicable sensor. -37No.PF-OMH0003-F PF2W20 Model PF2W20 PF2W504(T) PF2W520(T) PF2W540(T) PF2W511(T) Applicable sensor PF3W504 PF3W520 PF3W540 PF3W511 Rated flow range 0.5 to 4.0 2 to 16 5 to 40 10 to 100 L/min L/min L/min L/min Instantaneous Setting/display flow range 1 0.35
(Normally open) B 4 VP 5 6 24 VDC 12 VDC Thread type VG Rc Nil G F 7 240 VAC, 50/60 Hz 9 Other VP NPT N Option NPTF T Electrical entry S070 G Grommet D DIN terminal Port size VQ 04 06 10 1 2 Rc T Conduit terminal E Grommet terminal 3 4 Rc Rc 1 VKF Light/Surge voltage suppressor VQZ Nil None S With surge voltage suppressor (Only grommet type is only available.)
Suitable for use in vacuum applications 101.2 kPa (For vacuum specifications type: VT/VO325V) 02 1 G VT325 SY Thread type SYJ Nil F N T Rc G NPT NPTF For manifold: Enter VO.
1 o u t !0 VG VP S070 VQ VKF Part no. Material Replacement Parts Material Note Component Parts VQZ No. q w e r t y No. !0 !
Auto Drain Specifications/Option Combinations : Available : Not available Option Auto drain specifications Applicable model Auto drain specifications/Option D J T R AFF37B AFF75B D J R N.O. auto drain Drain guide IN-OUT reversal direction T With element service indicator Auto drain specifications 1 4 Option AFF75A to 220A AFF 75A 20 D Made to Order (How to Order and the applicable models
B T 0604 20 Refer to Best Pneumatics No. 6 for details on valves.
Thread T F N Orifice size 2 3 4 5 6 Rc(PT) NPTF G(PF) NPT 3mm 4.5mm 6mm 8mm 10mm Refer to table q for configuration. Port size 01 02 03 04 1 8 1 4 Valve/Body 0 2 Normally closed (N.C.)/single unit Normally open (N.O)/single unit 3 8 1 2 Refer to table q for configuration.
\ i n r t l l i r r ' t t l o n l qsilrrc NEW PRODUCT GUIDE Sil"Tivrc ,rt{ ll,( '!\'orlJ \ l.tf!
u t r EX260 Series EX600 Series Specifications Description Communication cable (With connector on one side) Field-wireable connector Part no.