The fitting hardware for element shall be assembled in such a method as shown by (b) and (c) of (Fig. 3). x : Bad example : Good example (a) Arranging condition of element (c) 4 pcs. arrangement (b) Arrangement of more 7 pcs.
The fitting hardware for element shall be assembled in such a method as shown by (b) and (c) of (Fig. 3). x : Bad example : Good example (a) Arranging condition of element (c) 4 pcs. arrangement (b) Arrangement of more 7 pcs.
Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window. c) How to command a Return to Origin operation. c-1) To perform a Return to Origin for each axis Select the button for the axis to be operated. c-2) To perform a Return to Origin for all axes Select the All axes Return to Origin button. d) The Return to Origin operation is completed when SETON is turned on.
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: S (Pressure Switch), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/4, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for
Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port: 01 (1/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port: 02 (1/4), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: S (Pressure Switch), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: CG (C + G), Attachment: S (Pressure Switch), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: S (Pressure Switch), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 1/4, Option: C + G, Attachment: Pressure Switch, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Standard
Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 1/4, Option: N.C. Float Type Auto Drain, Attachment: Pressure Switch, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Standard