SMC Corporation of America
Elite Part Number Search
Search Results "VV5FA5-20-101"

Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: without Option, Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: without Option, 1st Nominal Nozzle Size: 1 (ø0.7), 1st Selection Supply

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: C4H (ø4 One-touch Fitting, Straight Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 09 [ø5/16 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 06 [ø6 One-touch

. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 09 [ø5/16 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)