SMC Corporation of America
Elite Part Number Search
Search Results "CXSJL25-20-M9P"

Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 50, Valves

Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 50, Valves

Oscillation Angle A: 100°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 50, Valves: Provided

Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 50, Valves

Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 50, Valves

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 50, Valves: Provided

Oscillation Angle A: 100°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 50, Valves: Provided

Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 50,

Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 50, Valves

: M9P, Lead Wire Length(m): 5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Basic type, Rod Tip Shape: Rod end male thread, Custom-made Specifications: None

: M9P, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Type of Mount Support: Through-Hole / Both Ends Tapped Common (Standard), Rod Tip Shape: Female rod end, Custom-made Specifications: None

: M9P, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Through-Hole / Both Ends Tapped Common (Standard), Rod Tip Shape: Female rod end, Custom-made Specifications: None

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: No, Cushion: Rubber cushion, Operating Pressure

, Port thread type: M5 × 0.8, Auto Switches: M9P, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Custom-made Specifications: None, Lock unit magnet: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 325, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, Cushion: Rubber cushion, Specification: Built-in magnet, Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of

M Screw, Auto Switches: M9P, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Shaft Bearing: Ball bushing bearing, Custom-made Specifications: Clean Series, Specification of cylinder: Compact type

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9P, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,