SMC Corporation of America
Elite Part Number Search
Search Results "AF30-F03BD-8-A"

For the screw-in depth of the female threads, refer to the dimensions (page 10-19-8). As a rule, after the rod bottoms out, back off 1 to 2 turns.

For the screw-in depth of the female threads, refer to the dimensions (page 10-19-8). As a rule, after the rod bottoms out, back off 1 to 2 turns.

1 1 1 1 2 (a) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) Note 1) The above (a), (b), (c) indicate heater mounting positions.

PP W N A Z + Stroke Square nut insertion TW NL CY3B CY3R CY1S (mm) Model A 97 102.5 125 EB 21 22 24 H 46 54 63 HA 33.5 42.5 46 HB 33.5 41.5 46 HC 45 53 61.5 HG 17 16 25 HP 42 50 58.5 HT 19 23.5 28 J M5 x 0.8 M5 x 0.8 M6 x 1.0 L 106 108 138 LL 44 48.5 56 LW 71.5 75.5 86 M M5 x 0.8 M5 x 0.8 M6 x 1.0 MM 8 8 10 N 16.5 18 20.5 NL 15 15 18 NT 8 8 9 EA 26.5 26.5 29 CY1L CY1H15 CY1H20 CY1H25 CY1H

20 22 13 15 M8 x 1.25 8 12 10.5 13 27.5 36 ZPT16F-B5 ZPT20F-B01 16 18 2 Rc(PT)1/8 6.2 14 12.5 15.5 ZPT25F-B5 32 M5 x 0.8 5 9 ZPT 40/50 F-B 8/01 (Without Buffer/Female Thread) ZPT25F-B8 25 28 M8 x 1.25 8 12 36 ZPT25F-B01 Rc(PT)1/8 6.2 14 ZPT32F-B5 32.5 M5 x 0.8 5 9 ZPT32F-B8 32 35 M8 x 1.25 8 12 13 16 36.5 ZPT32F-B01 Rc(PT)1/8 6.2 14 Width across flats P N NL F D C Y 2.5 A B Dimensions A

Pressure gauge unit 2) e 2P 3P 4PL r t Sample Order Number Port Unit psig/bar MPa Code qIN wOUT eExtra bottom port (Outlet) rGauge port (Inlet) tGauge port (Outlet) AK1202S e q 8 8 8 8 w 8 8 8 8 r r No code MPA q w 2P 3P 4PL 5PC MPA MPA MPA V3 V3 V3 2) Pressure gauge unit MPa or psig/bar selectable.

Refrigerant R407C (HFC) IDF F Dimensions [mm] (A) Model A IDF190D 526 IDF240D 565 (B) Drain outlet Rc3/8 Replacement Parts: Motor Type Auto Drain Assembly *1 [mm] Dimensions Model A B C D IDF4E 154 348 Model Part no.

Body size Pilot style Stations Port size Valve stations Port size P Port R A Body size Pilot style Applicable Valve 2 2 stations Solenoid 1 Internal pilot VEX3222 6 2 02 1 4 6 stations Air operated: VEX3220 (1) Air operated 2 Common external pilot 8 stations 8 2 A B C 6 2 stations 3 8 1 4 VEX3422 Air operataed: VEX3420 (1) 1 Internal pilot 4 3 8 2 Common external pilot 1 2 3 8 6 stations

Since the vacuum pump capacity also affects the response time, consider all these points when operating. 8. When using a pressure gauge upside down like Fig. (1), it may result in a shifting of the zero point reading. Make sure to use it in the direction like Fig. (2). Caution 1.

JD 2-Rc 1/8 Port size 2-M5 x 0.8 (plug) Port size 2-JU 9 BB FA FD H 30 (UU) Q AW CB BC SD 15 DF (Through) AX AY Effective depth FC AV SF A BA BA 8 DG (Max. approx.

bolt CUJB4-4 -6 -8 -10 CUJB6-4 -6 -8 -10 -15 CUJB8-4 -6 -8 -10 -15 -20 CUJB10-4 -6 -8 -10 -15 -20 Model Mounting bolt CUJB4-4 -6 -8 -10 CUJB6-4 -6 -8 -10 -15 CUJB8-4 -6 -8 -10 -15 -20 CUJB10-4 -6 -8 -10 -15 -20 C D A M2.5 x 21l M2.5 x 23l M2.5 x 25l M2.5 x 27l M3 x 22l M3 x 24l M3 x 26l M3 x 28l M3 x 33l M3 x 22l M3 x 24l M3 x 26l M3 x 28l M3 x 33l M3 x 38l M3 x 22l M3 x 24l M3 x 26l M3

-W-m +HRL-JK001 G1/2 G1/2 G1/2 G1/4 G3/8 G3/4 HRL-EP018 NPT thread conversion fitting set NPT1/2 NPT1/2 NPT1/2 NPT1/4 NPT3/8 NPT3/4 HRL-EP011 G thread conversion fitting set HRLE090-A-m +HRL-JK001 G1 G1/2 G1/4 G3/8 G3/4 HRL-EP012 NPT thread conversion fitting set NPT1 NPT1/2 NPT1/4 NPT3/8 NPT3/4 HRL-EP013 G thread conversion fitting set HRLE090-W-m +HRL-JK001 G1 G1/2 G1/2 G1/4 G3/8 G3/4

Series LJ1 Top Mount (Using T-slots on the Mounting Frame) LJ1H20/LJ1S20 M6 bolt M6 bolt 33 33 2-T-slot Recommended dimension 8 (Refer to JIS B0952.) 20 0.02 A: Stroke + 124 A: Stroke + 32 92 0.02 A 92 92 A Positioning hole 2-8H10 4-T-slot Recommended dimension 8 (Refer to JIS B0952.) 67 Long positioning hole LJ1H30/LJ1S30 M8 bolt M8 bolt 30 30 2-T-slot Recommended dimension 8 (Refer to

In the case of 0.8MPa, when port A is a vacuum, port P can be pressurized to 0.8MPa (7kgf/cmG).

O O R D E R (N)AS S E R I E S W I T H O N E-T O U C H F I T T I N G S 1F NAS A R E A C O D E A P P L I C A B L E T U B E OD Japan, Asia, Australia, UK N Canada, USA MM 23 3.2 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 B O D Y S I Z E 1 M5 2 1/8, 1/4 Standard 3 3/8 Standard 4 1/2 Standard T H R E A D P O R T S I Z E M5 ...M5 U01 ..1/8 U02 ..1/4 U03

After the valve has shlfted, the pressu/e in the "A" pilot bullds up to the full 50 PSIG. lf the "8" pilot is pressurized, pressurizing the ..A" pitot has no eftect. Tho spool does not shift.

Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

+ + 20 + + + + + 20 stations S F G P R P R A, B port size R port 1/8 R port 1/8 N NPT A B B A M5 M5 x 0.8 A, B port M5 x 0.8, C4 P port 1/8 P port 1/8 T NPTF A, B port M5 x 0.8, C4 C4 One-touch fitting for 4 N3 One-touch fitting for 5/32" Type 41 (5 Port/Base mounted) Applicable solenoid valve SYJ340SYJ343How to Order SS5YJ3 41 05 C4 Type 41 Type S41 ( ) Single solenoid coil is on

-www.stevenengineering.com D-M9 D-F9W W D-M9V D-F9WV Hs Hs D-F9BAL Hs Hs D-A9 D-A9V D-M9, D-F9W D-M9V, D-F9WV Auto switch model W 19.5 21.5 B 4.5 4 A 11.5 12 W 5.5 6 B 4.5 4 A 11.5 12 Hs 17 19 B 0 0 A 7.5 8 W 1.5 (4) 2 (4.5) B 0 0 A 7.5 8 Symbol Bore size (mm) 12 16 D-F9BAL Auto switch model W 14.5 15 Hs 17 19 A 10.5 11 B 3.5 3 Symbol Bore size (mm) 12 16 ( ): Denotes the values of D-A93

When a load such as a relay or solenoid which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.