System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting
System: P (Vacuum Pump System, Single Unit), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Pump System
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 20, 25 Bore, Stroke: 100mm, Body Option: C (with Rubber Bumper), Auto Switch Groove: Z (ø20 to ø63, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch
Magnet: None, Mounting: B (Basic), Style: N (Rubber Bumper), Bore Size: 63mm, Thread: TN (Rubber Bumper: NPT 20 to 100; Air Cushion: M5: 20, 25; NPT: 32 to 100), Seal Material: R (NBR Seals, Nitrile Rubber), Stroke: 150mm
Stations: 01 (Station), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: R (Pressure Switch for Vacuum w/Energy Saving Function, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: W (Energy Saving), Unit Options: K (Vacuum Break Flow
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: E (Digital Pressure Switch for Vacuum / -100 to 100 kPa / NPN 2 Outputs), Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)],
Magnet: D (Built-in Magnet), Mounting: B (Basic), Style: N (Rubber Bumper), Bore Size: 80mm, Thread: Rubber Bumper: Rc: 20 to 100; Air Cushion: M5: 20, 25; Rc: 32 to 100), Seal Material: R (NBR Seals, Nitrile Rubber), Stroke: 300mm
Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 20, 25 Bore, Stroke: 10mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 20-25 Bore w/o Magnet; 32-63 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)
Magnet: None, Mounting: B (Basic), Style: N (Rubber Bumper), Bore Size: 32mm, Thread: TN (Rubber Bumper: NPT 20 to 100; Air Cushion: M5: 20, 25; NPT: 32 to 100), Seal Material: R (NBR Seals, Nitrile Rubber), Stroke: 100mm
Stations: 07 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: J (Vacuum Break Flow Adjusting Needle, Round Lock
Stations: 08 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: K (Pressure Switch for Vacuum w/Energy Saving Function, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: W (Energy Saving), Unit Options: K (Vacuum Break Flow
. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: L3 (without connector), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric), Bracket: w/o Option
Stations: 07 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: without Option, 1st Nominal Nozzle Size: 2 (ø1.0)