. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o
. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric)
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector
Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]
. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C4L (ø4 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation Manual: Y (w/o Operation
. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 2 (0 to -101 kPa, SI unit only, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric), Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type]
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection
. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric), Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: without Option, 1st Nominal Nozzle
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread, Connector Type: S (M12 Connector Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread, Connector Type: S (M12 Connector Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)