SMC Corporation of America
Elite Part Number Search
Search Results "RSQB32TN-20BZ-L"

: °C, Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: °C, Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: °C, Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

/humidity Note 1)Circulating fluid systemCooling water systemElectrical systemMass Note 10) (kg)Safety standardsCirculating fluid Note 2)Temp. range setting Note 1) ( C)Cooling capacity Note 3) (kW)Heating capacity Note 3) (kW)Temp. stability Note 4) ( C)Pump capacity Note 5) (50/60 Hz)(MPa)Rated flow Note 6) ( l/min)Main tank capacity Note 7) ( l )Sub-tank capacity Note 8) ( l )Port sizeWetted

capacity Note 8) ( l )Port sizeWetted parts materialTemperature range (C)Pressure range (MPa)Required flow Note 9) (50/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-HWater-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHFluorinertTM FC-40/GALDEN?

/humidity Note 1)Circulating fluid systemCooling water systemElectrical systemMass Note 10) (kg)Safety standardsCirculating fluid Note 2)Temp. range setting Note 1) ( C)Cooling capacity Note 3) (kW)Heating capacity Note 3) (kW)Temp. stability Note 4) ( C)Pump capacity Note 5) (50/60 Hz)(MPa)Rated flow Note 6) ( l/min)Main tank capacity Note 7) ( l )Sub-tank capacity Note 8) ( l )Port sizeWetted

min)Main tank capacity Note 7) ( l)Sub-tank capacity Note 8) ( l )Port sizeWetted parts materialTemperature rangePressure rangeRequired flow Note 9) (50/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunicationsHRZ008-L2Water-cooled refrigerationR134a (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RHClear water, Deionized water10 to 408.0 (at 20 C)1.25 (at 20

min)Main tank capacity Note 7) ( l)Sub-tank capacity Note 8) ( l )Port sizeWetted parts materialTemperature rangePressure rangeRequired flow Note 9) (50/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunicationsHRZ008-L2Water-cooled refrigerationR134a (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RHClear water, Deionized water10 to 408.0 (at 20 C)1.25 (at 20

min CFM L/min CFM lbs Kg 7 Port size Power supply Weight The compressed air that flowed in from the IN side passes through the 4 way solenoid valve, and after it is dehumidified at adsorption cylinder T1, it turns into dry air and exits from the OUT side.

Particle density for particle of 0.3m or larger is less than 3.5 particles/l Since it is possible to release exhaust air from pneumatic equipment directly into a clean room, piping to exhaust ducts is unnecessary.

Grease pack GR-L-005 (5g) GR-L-010 (10g) GR-L-150 (150g) Operation Warning 1. The speed may not be controllable during low speed operation with the meter-out controller. Caution 1. For Series CUX10, up to 0.1Nl/min (ANR) of internal leakage is anticipated due to cylinder structure. 4

min(ANR) Flow rate l/min(ANR) ARX21-01 ARX21-02 0.35 0.35 0.30 0.30 Downstream pressure MPa Downstream pressure MPa 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 Flow rate l/min(ANR) Flow rate l/min(ANR) Pressure characteristics Conditions: Upstream pressure 2.0MPa Downstream pressure 0.8MPa Flow rate

B L F D Basic Axial foot Front flange Double clevis Note) Lock position H R Rear end lock Front end lock Rail mounting CDBJ2B16-45-A Note) Front end lock only. Ex. Band mounting CDBJ2B16-60-B L 16 60 H N CBJ2 In case of the rail mounting type, screws and nuts for two auto switches are attached to the rail.

B RATE ADDRESS 1 64.4 72.16 64.4 59.8 78.9 72.16 64.4 L H 75.1 72.16 1 10 SETTINGS 0 L ERR L RUN BF DIA EX250 EX250 EX250 Max.118 Communication connector Communication connector Bus adaptor Power connector Power connector Ground terminal Ground terminal LINK IN LINK OUT Ground terminal Power connector BUS BUS 59.8 59.8 PWR PWR PWR 63 63 63 CANopen AS-i 1 power supply system 2 power supply

Interactive input display Programming with the same language as PC software ACTUATOR & CONSTRUCTION SYSTEM L c /BS HOLD STOP CONTROLLER POWER ALARM L R UP ENT DOWN /ESC MODE Able to execute operations such as programming, test runs and parameter changes, which up until now have been performed from a PC.