Base Mounted Wiring: 40 (Non Plug-in Individual Lead Wire Entry), Stations: 3 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8), Thread: F (G)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 6 Stations, Passage: 2 (P: Common, EA,EB: Common, Port A,B: Bottom), Port Size: 03 (3/8), Thread: T (NPTF)
Size: 100, Standard Dew Point: S (-60°C), Type: A, Thread: Rc(PT), Port Size: 03 (3/8), Accessory: B (Bracket)
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: RY (R + Y)
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: N (Non-Relieving Exhaust Mechanism), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 16 (1 + 6), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)
Function: 3 (3 Position Closed Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: B (Bottom), Port Size: 03 (Sub-plate 3/8)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Size: 50, Base Dew Point: -20°C, Type: A (Energy Saving Design), Equipment Connection: 4 (Modular Connection), Thread: Rc (PT), Port Size: 03 (3/8), Draining: C (N.C. Auto Drain), Option: P (Fitting for Purge Air Exhaust)
Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 4 (220VAC 50/60HZ), Electrical Entry: DO (DIN Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: N (NPT)
Base Mounted Wiring: 40 (Non Plug-in Individual Lead Wire Entry), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8)
Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: R (Flow Direction: Right to Left)
Size: 30, Standard Dew Point: -20°C, Type: A, Thread: N (NPT), Port Size: 03 (3/8)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 03 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)