SMC Corporation of America
Elite Part Number Search
Search Results "ISE77G-N02-L2-M"

Type: [Fitting] One-Touch / Screw, Fitting Type: Screw Mount Direction, Tube Size 1(φ): -, Threaded Adapter Shape: Female Straight, Body Material: [Brass] Brass (Electroless nickel plating), Application: Standard/Mini, Thread Portion Material: [Brass] Brass + Electroless Nickel Plating, Packing, Material of O-Ring: [Fluororubber] Fluorine Rubber, Compatible Fluid: Water / Air, Type Of Connection

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, DB, IF/PFA 1/4 INCH NPT VERSION, .72752 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, DB, IF/PFA 1/4 INCH NPT VERSION, .71650 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 2 COLOR DISPLAY DIGITAL PRESSU, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 0.46297 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 2 COLOR DISPLAY DIGITAL PRESSU, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 1.00122 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 2 COLOR DISPLAY DIGITAL PRESSU, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 0.5732 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 2 COLOR DISPLAY DIGITAL PRESSU, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 1.10231 lb

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring

25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns

25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns

25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns

Self align fittings series H, DL, L, LL has ten styles and five tube O.Ds providing a wide range of fittings that will fit any application. Flared ridge ferrule prevents accidental loss of ferrule when inserting tubing into the fitting body. Hardened ridge ferrule prevents breakage of ferrule when tightening nut. Flared I.D. provides low flow resistance inside the fitting. The tube holding

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled

The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled