SMC Corporation of America
Elite Part Number Search
Search Results "PF2D504-11-1"

: Internal pilot, Silencer built-in, Applicable valve: SV1000, P- and E-port entry position: Both side (2 to 20 series), Specified DIN rail length: -, Protective Structure: -, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 11

Pilot Specifications, Applicable valve: SV1000, P- and E-port entry position: Both side (2 to 20 series), Specified DIN rail length: -, Protective Structure: -, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 11

5/16" single-action pipe fitting (P-, E-Port), Specification: Internal Pilot Specifications, Applicable valve: SV1000, P- and E-port entry position: Both side (2 to 20 series), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 11

Size: 11 [112m³/hr (ANR), 65.9scfm], Option 1: Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure, Option 2: -

Size: 11 [112m³/hr (ANR), 65.9scfm], Option 1: Cool Compressed Air Output, Option 2: Terminal Block for Run & Alarm Signal

Size: 11 [112m³/hr (ANR), 65.9scfm], Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: Circuit Breaker

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A+L, Option 2: -

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: -

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A+C, Option 2: Circuit Breaker

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A+C+M, Option 2: -

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure, Option 2: -

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A+M, Option 2: Circuit Breaker

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: -

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: Terminal Block Connection

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: A+C+L, Option 2: Terminal Block for Run & Alarm Signal

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: R+T

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A+L, Option 2: R+T

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure, Option 2: R+T

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure, Option 2: R+T

Stations: 4 Stations, Cylinder Port Size: ø4 One-touch Fitting, P, R Port Size: ø8 One-touch Fitting, Kit Type: EtherNet/IPâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: -COM, Option 1: DIN Rail, DIN Rail Length: for 11 Stations; Longer Rail than Total Length of Specified Valve Stations, Option 2: -