SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-40-20-01N"

Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less

Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less

40 80 19 8 JIS Symbol Double acting MHZ 48 12 Double acting MHF 90 16 MHL MHR 141 20 MHK Note 1) At the pressure of 0.5 MPa, when gripping point L is 20 mm.

CRJ1 CRJ05 Model 30 25 Fr Allowable load (N) 25 20 FS(a) 25 20 FS(b) 6 5 Pinion gear Output shaft size (mm) Stopping the pinion gear by having it strike against the flat surface of the piston eliminates backlash.

DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system

Enclosure IP65 Enclosure Weight (g) IP65 [For M8: 20] [For M12: 40] [8 point integrated type, for M8: 55] Note) Weight (g) 100 (Input unit + end block) Note) Not including the DIN rail weight.

Positioning complete signal 19 OZ+ Z Z 10 20 COIN OZ+ 14 GND VDC 12 to 24V 13 4.7k COM Torque monitor: Zout 4.7k 12 + IM VDD 30V max. 15mA max. 11 Speed monitor: Zout 4.7k 4.7k SP + 21 CZ Z (Pin 14 is GND.) 26 FG CN I/F 205 Non-standard Motor Compatible Drivers Mitsubishi Electric Corporation Drivers for LJ1, LG1, LX Dimensions (RS-232C without optional unit) Driver 5 100 40 1-5 hole 5

Operating Pressure MPa How to Order 2 TH0425 TH0806/TH1075/TH1209 TH0604 Metric size TH0604 N 20 1 TH1008/TH1210 Length per roll Indication of tubing model Roll size 20m roll 100m roll Symbol 20 100 0.5 Color indication 0 -20 0 20 40 60 80 100120140160180200 Color Symbol N R BU B Translucent Red (Translucent) Blue (Translucent) Black (Opaque) Operating Temperature C Note) The maximum operating

Model g (oz) ZFA100 50 (1.75) 1/8 140 (4.94) High flow rate square type ZFA200 200 (7) 1/4 190 (6.71) ZFB10 10 to 20 (0.35 to 0.7) 4, 6, 3/16", 1/4" 22 (0.78) ZFB20 30 to 50 (1.05 to 1.75) 6, 8, 1/4" 30 (1.06) Universal type ZFB30 75 (2.63) 10, 3/8" 40 (1.41) ZFB401 100 (3.5) 1/2" 62 (2.19) ZFA100 Specifications Air, Nitrogen Fluid Negative pressure Operating pressure 0.5MPa (72.5psi) Withstand

or less Battery Nickel hydride secondary battery 3.6V Charging time: 72 hours Battery replacement guide (Note 3) 2 years Motor allowable RPM when power supply is shutoff [rpm] 800 400 200 100 Battery retention condition/period Note 4) 5) Duration guide of retention (day) 2 5 10 20 Cooling system Natural air cooling Operating temperature range [C] Note 6) Screw mounting: 0 to 40 (No freezing

VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.

Ratio of discharge amount to fresh water () 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPas) mPas Recommended typical condition B: Calculate discharge amount of fluid with viscosity 100mPas in case of discharge rate 4.5L/min and discharge pressure 0.1MPa. 1. Find ratio of discharge rate to fresh water for the fluid with viscosity 100mPas from the graph.

Maintenance P.17 1) Inspection P.17 2) Overhaul P.18 3) Disassembly P.18 4) Assembly P.19 5) Expendable supplies P.20 6) Replacement procedure of seal P.21 7) Inspection P.22 5. Troubleshooting P.23 6. Construction P.26 7.

Installation 20 How to measure 22 Count measurement 23 Installation 23 How to measure 23 Troubleshooting 24 Cross-reference for troubleshooting 24 Error display 25 When necessary Specification 26 Specifications 26 Dimensions 27 -1No.SFOD-OMS1007-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Operating Environment Warning How to Find the Flow Rate How to Find the Flow Rate How to Find the Flow Rate How to Find the Flow Rate (at air temperature of 20 (at air temperature of 20 (at air temperature of 20 (at air temperature of 20 ) ) ) ) Do not use valve in atmosphere of corrosive gases, chemicals, salt water, water or steam or where there is direct contact with any of these.

Connection Thread Tightening Method Chamfer Dimension for Female Thread Chamfer dimension D (Recommended value) (mm) M5 5.15.4 10-32UNF 5.05.3 Rc1/8 10.210.4 Rc1/4 13.613.8 Rc3/8 17.117.3 Rc1/2 21.421.6 NPTNPTF1/8 10.510.7 NPTNPTF1/4 14.114.3 NPTNPTF3/8 17.417.6 NPTNPTF1/2 21.721.9 Connection thread size Tightening torque Nm NPTR1/8 3 to 5 NPTR1/4 8 to 12 NPTR3/8 15 to 20 NPTR1/2 20 to 25

Operating Environment Warning How to Find the Flow Rate How to Find the Flow Rate How to Find the Flow Rate How to Find the Flow Rate (at air tempe (at air tempe (at air tempe (at air temperature of 20 rature of 20 rature of 20 rature of 20 ) ) ) ) Do not use valve in atmosphere of corrosive gases, chemicals, salt water, water or steam or where there is direct contact with any of these.

For details of each setting, refer to page 18 to 20 of this manual. Please refer to the PLC manufacturer's manual etc. for details of programming and addresses. For the PLC protocol and programming refer to the relevant manufacturer's documentation.

Lock unit specification Lock unit model MWB32-UT MWB40-UT MWB50-UT MWB63-UT MWB80-UT MWB100-UT Applicable rod size mm *2 12 f8 16 f8 20 f8 20 f8 25 f8 30 f8 Locking operation type Exhaust locking Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Min. operating pressure 0.3MPa Ambient and fluid temperature -1070 (No freezing) Operating fluid temperature Lubrication Not required