Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40
ASS ASR ASF Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
NPN) C76 IC 5 V Grommet C73 B54 C73C A33A A34A A44A B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW H7BA H7NF 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Yes Connector 12 V 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC Grommet DIN terminal Diagnostic indication (2-color) 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Grommet 12 V 2-wire Connector 3-wire (NPN) 2-wire
0 CG1YB20 -200 Example Smooth cylinder combined with precision regulator (e.g.
Relationship of liquid entry and sliding distance Amount of liquid entry (g) X 15 10 Standard cylinder Stainless steel cylinder 5 0 50 100 150 200 Sliding distance (km) 250 300 Conditions Working fluid ...Air Pressure .. 0.5MPa Liquid ...
Common exhaust(pilot and main valve)type Pilot exhaust Not required Lubrication Free Mounting position 150/30 Impact / Vibration resistance m/s2 Dust proof Protection structure Base mounted type Solenoid Specifications Grommet (G), E(H), L type plug connector (L), M type plug connector (M) Electrical entry Coil rated voltage V DC 24, 12, 6, 5, 3 Internal pilot AC 50/60Hz 100, 110, 200, 220
VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
IRV Note for P1 VEX Stations Dimension 2 3 4 5 6 7 8 91 122 107 153 184 215 246 277 76 138 169 200 231 262 L1 L2 Confirm internal pilot or common external pilot by checking whether P1 has a M5 screw or not. Internal pilot P1 has no M5 screw. Common external pilot P1 has an M5 screw. SRH SRP VVEX4 SRF Connection mark All types are the same in terms of connection.
AME150 AME250 AME350 AME450 AME550 AME650 AME850 Model Note) 200 500 1000 2000 3500 6000 12000 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.
AT ID 1 Standard 11 2 Standard Accessory (Option) AMG Description Bracket Symbol Nil Rc Thread type Nil AFF B JIS Symbol F G N NPT N.C. auto-drain C AMG N.O. auto-drain D AM Refer to the table below for accessory/Option combinations. Port size Misc.
When the pump is used continuously for extended periods of time, make the OFF time appropriately longer with the minimum ON time of 200 msec to set the operating frequency to 1 Hz or less. When using this product with the maximum operating frequency or less, the coil temperature may rise due to ambient temperature and energizing time, so makethe OFF time appropriately longer.
In case that the cyclic temperature is beyond normal temperature changes, the inside of the Fieldbus system is likely to be adversely affected. 11. Do not use in direct sunlight. This may cause equipment failure or malfunction. 12. Monitor the ambient temperature range. Failure to do so may cause a malfunction. 13.
Select compatible materials of construction for the gas Vacuum to 125 psig (0.9 MPa) 200 psig (1.4 MPa) 375 pisg (2.7 MPa) -10 to 71C (No freezing) 0.29 0.5 Inboard leakage Outboard leakage 2 x 10-11 Pam3/s 2 x 10-10 Pam3/s 1) 4 x 10-9 Pam3/s 1) Ra 10in. (0.25 m) Face seal, Tube weld 60 to 110 psig (0.4 to 0.76 MPa) M5 x 0.8 Top Bottom mount 0.06 in3 (1.07 cm3) 0.24 kg 2) Leak rate Across
M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D. Metric size Inch size P . 15-11-3 3.2 With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Use 1/8" tube. 23 04 06 08 10 12 01 03 05 07 09 11 13 4 6 8 10 12 Flow Direction Symbols on Body JIS Symbol Symbol 15-9-10
.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] A 1-5V 1-5V 4-20mA (Hysteresis) ON OFF 90% () Ka (copy function) () 10 L/min 10 L Sa ON OFF ON OFF , , 2 5 10 L/min 5 ,10550 L ON-OFF 1 L/min ,10 11 12 1 L/min -13No.PF-OMN0011CN-C SI SI Ta ON-OFF Na ON 0 Ha -14No.PF-OMN0011CN-C M38 L(2 ) (ZS-26-B) (ZS-26-01) ZS-26-01 1 (ZS-26-B) 190 2,1/41/2 72 2, , -15No.PF-OMN0011CN-C , 1 DC() 2 N.C
1 Check Valve Series AK Large flow capacity Low cracking pressure: 0.02 MPa A wide variation of models Model Model Effective area (mm2) Port size Weight (g) 1 8 AK2000-01 25 105 1 4 AK2000-02 27.5 100 1 4 AK4000-02 47 155 3 8 AK4000-03 85 150 1 2 AK4000-04 95 140 3 4 AK6000-06 200 345 AK6000-10 230 315 1 Specifications AS Fluid Air Proof pressure 1.5 MPa ASP Maximum operating pressure 1 MPa
11 100+55!fl 110+559120+559 Differenl 1 5 90 100 1 1 0 Same 90 100 1 1 0 Ditterent 15+5d!
9.6/19.2/45.45/93.75/ 187.5/500 kbit/sec 1.5/3/6/12 Mbit/sec Communication speed 125/250/500 kbit/sec 57.6/115.2/ 230.4 kbit/sec 156/625 kbit/sec 2.5/5/10 Mbit/sec Rated voltage 24 VDC Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (with power drop warning at approx. 20 V) Power supply voltage range Communication power supply for DeviceNet 11
{9Ti 3 4 5 6 cylinder axis: Lo (cm) t 300 ; 200 i'i 100 = P e .F 20 '10 9' -4!2 E 1 0 E E _ E 5 E E c r l 0 1 2 3 4 5 6 7 I I 101112131415 Distance from cylinder axis: Lo (cm) Example The required load, Fo =100(N) and the moment arm, L0 = Bcm refering to Data 1, draw a vertical line from the 8cm value of the horizontal axis.