SMC Corporation of America
Elite Part Number Search
Search Results "AF20-01-6-A"

BBA2: D-A7/A8/F7/J7 The above stainless steel screw kit is used for auto switch D-F7BAL and D-F7BAVL when it is shipped mounted on a cylinder. Also, BBA2 is included when a auto switch alone is shipped. 3 Plate Cylinder with Lock Series MLU Construction !4 !7 !0 !4 @1 u q !3 !2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !

Hs A B A B Proper auto switch mounting position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W D-F7LF Bore size (mm) B B A A B A B A B A 32 11 10 50 51 3 43 6 46 5.5 45.5 40 13.5 12.5 56.5 57.5 5.5 49.5 8.5 52.5 8 52 50 18 19 61.5 60.5 11 53.5 14 56.5 13.5 56 63 22 21 67 66 14 59 17 62 16.5 61.5 Auto switch mounting height

SMC's VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series.

L1 D L2 L3 L4 L5 L6 L8 Model Port size AS2000E-01 4.5 16 57 61.5 15.5 10 17 30 5 40 1/8 AS2000E-02 4.5 20 59 63.5 17 12 23 30 5 40 1/4 AS3000E-02, 03 5.5 26 69 76 20.6 13.25 25 45.5 5.25 56 1/4, 3/8 AS4000E 2-1/4 to 1/2 72 (Max. 80) Effective thread depth 6 15-9-42

Manifold mounting screw A Mounting manifold to DIN rail: 1) Hook the mounting hook on the "B" side of the manifold base to the DIN rail. 2) Push side "A" onto the DIN rail and tighten the clamp screw on the "A" side of the end plate.

Dont use a wrench on push-to-connect end. 2 2 Cut tubing square with a clean 90 edge Dont use excessive tube angle cut which can lead to leakage or breaking. 90 90 3 3 Use SMC Tube Cutters Dont use dikes, a knife, a saw or a dull tool to cut the tubing.

Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption W (Holding) Temperature rise (C ) (Rated voltage) 4.5 45 3.2 35 6 55 7.5 60 6 50 8 60 11 65 9.5 60 11.5 65 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage. Changing a coil from AC to DC is possible, but it's impossible to change from DC to AC.

Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting

Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included

Contact us when such a type is needed.

Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 42 52 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 56 65 Two mounting screws (for mounting

Open the sealed package inside a clean room. These products are packaged in sealed double packaging in a clean room. It is recommended that the inside packaging be opened in a clean room or other clean environment. 2. Flush out the piping. ITV IC ITVH ITVX Connect these products to piping only after it has been flushed and cleaned properly.

Storage of data other than the request message to store When a parameter is changed with a key-in operation, the product stores all parameters into the EEPROM even if not receiving a request message to store. 3-6 HEF002-A6 Communication Format 3.7 Communication Example Communication example of request message to read Request message from master: Request the product having a set address of

Storage of data other than the request message to store When a parameter is changed with a key-in operation, the product stores all parameters into the EEPROM even if not receiving a request message to store. 3-6 INR-244-831 Communication Format 3.7 Communication Example Communication example of request message to read Request message from master: Request the product having a set address

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

D L2 L3 L4 L5 L6 L7 L8 P d h T L1 Model Model ASS10 ASS100 ASS110 2 10 5 20 9 5 20 52 14 4 17 50 XT14-82-3-1 1 8 ASS30 ASS300 ASS310 3.2 12 6 30 12 6 26 73 23 5 16.5 63 XT14-105-5-1 1 4 3 8 , ASS500 ASS500 2.3 14 7 35 13 6 38 99 27 6 30.5 90 XT14-89-2-1 1 2 3 4 , ASS600 ASS600 3.2 14 7 65 14 6 46 116 31 6 26 112 XT14-85-2-1 3 4 1 , AS Meter-in Control Type Meter-out Control Type ASP Mounting

(Metric size) ASV 4 6 6 10 8 4 Flow rate [L/min (ANR)] It may damage the body A or fittings. 100 130 230 290 660 920 AK Controlled flow Body A Free flow Sonic conductance [dm3/(sbar)] 0.28 0.36 0.64 0.8 1.8 2.6 VCHC Controlled flow Free flow 0.2 0.25 0.2 0.25 0.2 0.25 0.2 0.25 Caution Release from One-touch fitting Critical pressure ratio ASR ASQ Note) Flow rate values are measured at 0.5