available in 3 sizes; 1/4 (20), 3/8 (30) and 1/2 (40).? Rc(PT), PF and NPT threads are available. Port sizes range from 1/8 to 3/4. Body size 30 and 40 now have a transparent bowl guard that offers 360 visibility, while completely protecting the bowl from the environment.? Accessories include a bracket, and float type auto drain. AFD MASS PRO. MICRO MIST SEPARATOR. AIRLINE EQUIPMENT.
The AFM's standard filtration is 0.3µm with a 99.9% filtered particle size. Body size 30 and 40 now have a transparent bowl guard that offers 360° visibility, while completely protecting the bowl from the environment. The modular design allows connection with other SMC air preparation equipment. Use in combination with the AF series to meet your clean room filtration requirements.
The AFM's standard filtration is 0.3µm with a 99.9% filtered particle size. Body size 30 and 40 now have a transparent bowl guard that offers 360° visibility, while completely protecting the bowl from the environment. The modular design allows connection with other SMC air preparation equipment. Use in combination with the AF series to meet your clean room filtration requirements.
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 30, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 02 (1/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FITLER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DA, AW MASS PRO 1/4 MODULAR (PT), 1.21070 lb
This is a legacy product.
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc.
Series: -, Body Size: -, Thread: -, Port Size: -, Mounting: -, Float Type Auto Drain: -, Bowl Type: -, Bowl Guard: -, Drain Port: -, Indicator: -, Flow Direction: -, Drain Cock w/Barb Fitting: -, Pressure Unit: -
Series: -, Body Size: -, Thread: -, Port Size: -, Mounting: -, Float Type Auto Drain: -, Bowl Type: -, Bowl Guard: -, Drain Port: -, Indicator: -, Flow Direction: -, Drain Cock w/Barb Fitting: -, Pressure Unit: -
Series: -, Body Size: -, Thread: -, Port Size: -, Mounting: -, Float Type Auto Drain: -, Bowl Type: -, Bowl Guard: -, Drain Port: -, Indicator: -, Flow Direction: -, Drain Cock w/Barb Fitting: -, Pressure Unit: -
Series: -, Body Size: -, Thread: -, Port Size: -, Mounting: -, Float Type Auto Drain: -, Bowl Type: -, Bowl Guard: -, Drain Port: -, Indicator: -, Flow Direction: -, Drain Cock w/Barb Fitting: -, Pressure Unit: -
Series: -, Body Size: -, Thread: -, Port Size: -, Mounting: -, Float Type Auto Drain: -, Bowl Type: -, Bowl Guard: -, Drain Port: -, Indicator: -, Flow Direction: -, Drain Cock w/Barb Fitting: -, Pressure Unit: -