It is already built-in to the rectifier circuit. 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
Solid state switches marked with a "p" symbol are produced upon receipt of order. 2 Series MLGP Cylinder Specifications Action Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Cushion Lubrication Stroke length tolerance Double acting Air 1.5MPa (217 psi) 1.0MPa (145 psi) 0.15MPa (22 psi) -10C to 60C (14 to 140F) 50 to 500
Refer to Flow Characteristics (page 14-20-32) and figure of Max. Air Flow (page 14-20-30).
Lubrication Equipment Applicable oil viscosity (cSt (3)(40C)) Application Port Size Bowl capacity (cm3) Option Page Series (1) M5 to 1 Lubricator AL1000-6000 Individual lubrication Bracket 1,000cm3 Tank Float switch 130 1,000 32 1.17-2 32 1 1/4 to 2 Large flow lubricator AL800, 900 Individual lubrication 500 1,000 1.17-8 1,000cm3 Tank Float switch (2) 5,000 9,000 1.17-11 32 Auto Feed Lube
(except IDG1, IDG5) Maintenance Part Lists PA3000/Automatically operated type PA5000/Automatically operated type PAX1000 KT-PA5-31 KT-PA3-31 KT-PAX1-31 Diaphragm kit (PTFE) Diaphragm kit (PTFE) Diaphragm kit (PTFE) KT-PA5-32 KT-PA3-32 KT-PAX1-36 Check valve kit Diaphragm kit (NBR) Diaphragm kit (NBR) KT-PA5-36 KT-PA3-36 KT-PAX1-37 Check valve kit Check valve kit Switching valve parts kit
ZQ-OM01401-B / / ZQA No.ZQ-OM01401-B 2 1. 5 2. 9 3. 11 3.1. 11 3.2. 12 3.3. 13 3.4. 14 3.5. 16 4. 17 5. 19 6. 20 7. 21 8. 28 9. 32 10. 35 11. 37 12. 40 13. 42 1 - No.ZQ-OM01401-B /ZQA *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery
inch inch 4 mm 6 mm 1/4 5/32 inch inch () PBTCB156PPSO HNBR C3604( ) POMSUS304NBRC3604 SUS304NBR 22 g 32 g 34 g 25 g 26 g 27 g 28 g 28 g 34 g 35 g 2(AWG26) 0.15 mm 1.0 mm (3 ) 3.4 -63No.PS-OMS0006CN-G M5 7 3.5 01/N01 A 01 R1/8 10 N01 NPT1/8 12 C4HC6HN7H 2.5 A B C4H 15.6 8 C6H 16.5 10 N7H 16 10.3 C4LC6LN7L C A B C D C4L 15.2 17.5 4 8.2 C6L 15.2 18.3 4 10.4 N7L 20.9 20.6
(except IDG1, IDG5) Maintenance Part Lists PA3000/Automatically operated type PA5000/Automatically operated type PAX1000 KT-PA5-31 KT-PA3-31 KT-PAX1-31 Diaphragm kit (PTFE) Diaphragm kit (PTFE) Diaphragm kit (PTFE) KT-PA5-32 KT-PA3-32 KT-PAX1-36 Check valve kit Diaphragm kit (NBR) Diaphragm kit (NBR) KT-PA5-36 KT-PA3-36 KT-PAX1-37 Check valve kit Check valve kit Switching valve parts kit
SYJ300/500/700 3 PORT SOLENOID VALVE Low Power Consumption; Interchangeble with the NVJ and NVZ; Vacuum Applicable; Base-Mounted and Body-Ported Options. AKB/AKH CHECK VALVES Available with One-Touch Fitting; Bushing Type and Straight Type; Applicable OD in metric: 4, 6, 8, 10, 12 and in imperial: 5/32, 1/4, 5/16, 3/8, 1/2.
1,000 14-13-3 to 2 1,000 cm3 tank Float switch 32 4 1 2Note) to 2 4 1 32 Auto feed lube ALF400 to 900 With auto lubrication function Bracket 14-13-6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 1 32 Auto feed tank ALT-5/-9 With inlet pressure insulation function
Port R Operating Fluid and Ambient Temperature Operating fluid temperature (C) (3) Vacuum Ambient temperature (C) Temperature conditions Air (Standard) Oil (Standard) (V) Port P Port A Maximum Minimum 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V in parentheses is option symbol. Option Material No.
DataA: Inlet Air Temperature F 80 90 100 110 120 130 140 149 C 27 32 37.8 43 49 54 60 65 IDFB60/IDFB70 1.33 1.21 1.00 0.78 0.61 0.48 0.38 0.28 IDFB80/IDFB90 1.38 1.38 1.00 0.83 0.63 0.50 0.45 0.37 DataB: Ambient Temperature F 80 90 100 110 113 C 27 32 37.8 43 45 IDFB60/IDFB70 1.16 1.11 1.00 0.78 0.71 IDFB80/IDFB90 1.40 1.22 1.00 0.88 0.83 DataC: Inlet Air Pressure psi 50 60 70 80 90 100 120
Double acting cylinder theoretical output Operating pressure Bore size mm Pressurized area Rod diameter mm Operating direction 0.3 0.5 0.7 0.9 mm2 125 32 OUT IN 140 32 OUT IN 160 38 OUT IN 6) Kinetic energy absorbed by cushion mechanism Table 4.
16.8 -06E 4.7 17 6 12.8 22.3 10.1 18.4 17 1/8 19 43.4 M16 x 1 20 -08E 18.5 8 30.2 15.7 6 22.6 22 24 46.4 M20 x 1 22 -10E 21 10 54.7 22.6 17 47 M14 x 1 16.8 KK4P-06E 4.7 17 6 12.8 30.6 10.1 17 19 50.2 M16 x 1 20 -08E 6.2 18.5 8 22.6 38.2 19.8 25.2 1/4 22 24 53.2 M20 x 1 22 -10E 7.7 21 10 35.3 61.4 27.6 54.2 -12E 9 75.2 40.2 24 27 M22 x 1 23 22 12 50.9 60.1 KK6P-12E 9.2 86.1 41.2 31 1/2 30 32
16.8 -06E 4.7 17 6 12.8 22.3 10.1 18.4 17 1/8 19 43.4 M16 x 1 20 -08E 18.5 8 30.2 15.7 6 22.6 22 24 46.4 M20 x 1 22 -10E 21 10 54.7 22.6 17 47 M14 x 1 16.8 KK4P-06E 4.7 17 6 12.8 30.6 10.1 17 19 50.2 M16 x 1 20 -08E 6.2 18.5 8 22.6 38.2 19.8 25.2 1/4 22 24 53.2 M20 x 1 22 -10E 7.7 21 10 35.3 61.4 27.6 54.2 -12E 9 75.2 40.2 24 27 M22 x 1 23 22 12 50.9 60.1 KK6P-12E 9.2 86.1 41.2 31 1/2 30 32
Symbol Port specifications Porting specifications (A,B) trA FB I 2 Common Common Side Bottom Series 1N313 Serial I rN313 AB I Allen Bradley DN I DeviceNet MB I l\4itsubishi PB I Prolibus 2 i 32 outputs/32 inputs AB2 Accessories D-sub cable with connectors on both ends.
No.PS-OMU0005CN-C // ZSE20B(F) ISE20B 2 8 10 11 15 15 17 20 [] 23 24 3 25 27 29 29 29 F0 31 F1 OUT1 32 F1 OUT2 35 F3 37 F4 38 F5 FUNC 40 F6 42 F10 43 F11 49 F80 50 F81 51 F82 53 F90 54 F96 56 F97 57 F98 59 F99 61 62 66 66 67 76 76 79 -1No.PS-OMU0005CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO
OFF ON SET2OUT1 ()[P_2][n_2]OUT2 SET2 1SET 2SETSET2 3(32)OFF ([SEt]) -25No.PS-OMV0008CN-E 25 P1L()P1H()WH1() dtH/dtL() (n1L n1H) 34 OUT2 -26No.PS-OMV0008CN-E SET3~5[F 0] [F] SET2 SET 3 ~5 FO F1 F99 ()[-] -27No.PS-OMV0008CN-E [F 0] 30 [M]MPa PNP ALL [F 1] OUT1 32 OFF ISE70G0.500 MPa ISE75G1.000 MPa ISE76G2.50 MPa ISE77G5.00 MPa ISE78G8.00 MPa ONOFF ISE70G0.050 MPa ISE75G0.100
CLR OFF Address 64 (No.1) 32 (No.2) 16 (No.3) 8 (No.4) 4 (No.5) 2 (No.6) 1 (No.7) HOLD Output is held when a communication error occurs. ON 0 OFF OFF OFF OFF OFF OFF OFF 1 OFF OFF OFF OFF OFF OFF ON : HOLD/CLR setting is made available per one point by parameter setting.
Tube Size Packaging Table 01 03 05 07 09 11 13 15 19 1/8 5/32 3/16 1/4 5/16 3/8 1/2 5/8 3/4 Tube Size Type A (Monowall) Type B (Reinforced) TIV01 TIV03 TIV05 TIV07 TIV09 TIV11 TIV13 TIV15 TIV19 3/4 1/8 5/32 3/16 1/4 5/16 3/8 1/2 5/8 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 Length (Meters) S S S S S S S S