Information tab The tab for Information consists of (A) Unit information, (B) System configuration and (C) Description. (A) (B) (C) (A) Unit information The unit information area indicates the unit information. Wireless slave unit information NFC access Description Content Energized Not energized Part No.

Note2) A (set) side energization : A light (orange) illuminates, B-(reset) side energization : B light (green) illuminates.

Table 3.8-2 RTU mode message frame a)Start b)Slave Address c)Function d)Data e) Checksum (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).

HRR018-A (A 10) Model A B HRR012/018-A-1070 45 HRR012/018-A-2080 61 HRR012/018-A-20-U 80 50 440 (Includes protruding parts) Ventilation air outlet Ventilation air inlet 550 B 5 50 Power supply connector Operation display Circulating fluid return port Rc1/2 Serial communication connector Power supply switch Circulating fluid fill port Fluid level gauge Handle Contact input/output communication

Piping adapter Spacer with Bracket Mounting Position Dual residual pressure release valve (-X538) Dual residual pressure release valve with soft start-up function (-X555) (Max. 10) 201.8 82.9 (14) (14) 201.8 (Max. 10) 82.9 IN OUT IN OUT d c b a d a b c Model a b c d Note Model a b c d Note VP544-5DZ1-03-X538 33.9 57.2 95.7 220.7 AW30-03G-A Y300T-A E300-03-A VP544-5DZ1-03-X555 33.9 57.2 129.2

L 1 1.5m U 1 1 3 3m V 2 2 W 3 3 5 5m Shield 8 8m Vcc B-1 12 A 10m GND A-1 13 A B-2 7 B 15m A A-2 6 C 20m B B-3 9 B A-3 8 Z B-4 11 Z A-4 10 3 10.5 14.2 2 1 5.6 23.7 A1 2 (7.0) 1 3 3 4 B1 12.7 2 1 18 A4 B4 (6.7) 15 16 11 30.7 44 - 11.2 () L 1 1.5m U 1 1 3 3m V 2 2 W 3 3 5 5m Shield 8 8m Vcc B-1 12 A 10m GND A-1 13 A B-2 7 B 15m A A-2 6 C 20m B B-3 9 B A-3 8

HRS400-A-46 3.7 Communication sequence 3-7 DOC1003626 Chapter 3 Serial communication Table 3.8-1 ASCII mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (LRC) f)End [:] XX XX XX XX XX XX XX XX [CR] [LF] a) Start The start of the message. [:](3Ah) (ASCII) b) Device Address This is a number to identify this product. 1" is the default setting.

B 19.5 25 29.5 C 6.5 7 14.5 A 8 8 8 8 10 10 Model MGQ32 MGQ40 MGQ50 MGQ63 MGQ80 MGQ100 Detailed figure of a section Detailed figure of b section a a a b MGQ32 to 50 MGQ63 to 100 8-20-10 11 Compact Guide Cylinder Series MGQ Proper Auto Switch Mounting Position (Detection at stroke end) Minimum Stroke for Auto Switch D-Z7/Z80 D-Y5/Y6/Y7(V) D-Y7W(V) 1 pc. 2 pcs. 5 10 5 5 10 15 Auto switch D-Z7

B-1 2 L A A-1 1 B B-2 6 1 1.5m B A-2 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 S 9 B A-6 8 3 14.2 2 1 (8) 14 18 B1 A1 17.7 5 6 2 1 A6 B6 15 16 11 30.7 112 [820m] A B-1 2 A A-1 1 L B B-2 6 8 8m B A-2 5 COM-A/COM B-3 3 A 10m COM-B/ A-3 4 B 15m Shield C 20m Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.

Information tab The Information tab consists of (A) Unit information, (B) System Configuration and (C) Description. (A) (B) (C) (A) Unit information The Unit information area indicates the unit information. Module information NFC access Description Content Energized Not energized Part No.

V 10 100 10 14-9-3 4 Series VBA1110 to 4200 Construction/Principle VBA1 VBA1110/2100/4100 Governor Drive chamber A Booster chamber A Governor Drive chamber A Drive chamber B IN (Inlet side) IN (Inlet side) Booster chamber B Drive chamber B Piston Rod Piston Booster chamber A Piston Switching valve Check valve Booster chamber B Check valve Switching valve OUT (Outlet side) OUT (Outlet side

Mounting Position (Detection at Stroke End) and Its Mounting Height D-M9 D-M9W D-M9A D-A9 A 22 [24] (24.5) W B [ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5

A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

121.5 138 161 20 24 24 130.5 148 171 8 10 12 55 63 74 Port size/Flange: 32F, 40F, 50F J (Valve open) Indicator (Option) Pilot port E 12(P1), 10(P2) Port size: refer to table below P1 P2 H H D B A 32 B C G F 4 x 2 x 18 mounting hole A Applicable flange 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H J Model VND50D-32F VND60D-40F VND70D-50F 8 10 12 50 40 32 1 8 1 4 1 4 130 150 180 211.5

2(A) 2(A) 1(P) 3(R) 2(A) 2(A) 3(R) Air operated Model Port size (External/ Internal) Pilot solenoid C [dm 3/(sbar)] b C [dm 3/(sbar)] b C [dm 3/(sbar)] b C [dm 3/(sbar)] b VEX312-01 1/8 2.4 0.19 2.4 0.31 2.3 0.36 2.5 0.22 0.1 0.2 VEX312-02 1/4 3.5 0.35 3.3 0.49 3.1 0.46 3.5 0.33 0.1 0.2 VEX332-02 1/4 4.1 0.36 4.3 0.42 4.1 0.41 4.6 0.25 0.3 0.4 VEX332-03 3/8 8.7 0.29 7.9 0.52 7.8 0.51 8.7

VFR VP450 VP470 VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 82 (3 position: 98.5) 129 VZS 71(95.5) VFS 139.5 B A B A VS4 VQ7 (External pilot port) 1/8 (External pilot port) 1/8 EVS VFN A B B A B B B A EA P EB P EA EB ( ): Port size 3/4, 1 Dimensions: Port

Air pressure supplied from A operates on surfaces 1 and 2. (extension) A B Air pressure supplied from B operates on surface 3. (retraction) A B Mounting accuracy improved Positioning holes are provided on the work piece mounting surface for easy alignment. Regulator with check valve is unnecessary A regulator with check valve normally required for a lifting circuit becomes unnecessary.