If there is a risk of contact, provide safety measures such as a cover or a system that uses sensors that will activate an emergency stop before contact is made. wUse a balance circuit in which lurching of the piston is taken into consideration.

View A-A (Internal connection diagram) Conduit When used as an IP65 equivalent, use seal to install the wiring conduit. Also, use the tightening torque below for the conduit.

Example 1:How many sctm will flow through a valve with a C, of 1 .0 given a supply pressure ot 80 psig and a 20 psi pressure drop? From the chart Fig. 3.10 find 80 psig on the criticalflow line. Next, lind 60 psig (80 psig minus a 20 psi pre*sure drop) on the horizontral axis at the bottom.

Example 1:How many sctm will flow through a valve with a C, of 1 .0 given a supply pressure ot 80 psig and a 20 psi pressure drop? From the chart Fig. 3.10 find 80 psig on the criticalflow line. Next, lind 60 psig (80 psig minus a 20 psi pre*sure drop) on the horizontral axis at the bottom.

SUP/EXH block assembly specifications 20 20 stations Note 1) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout.

Built-in silencer, Direct exhaust [-S] When ordering assemblies incorporated with a manifold, add suffix S to the manifold No. This is an exhaust port on a top the manifold end plate. The builtin silencer exhibits an excellent noise suppression effect.

VV5K3-20-06 VV5K3-40-06-M5 Common SUP/Common EXH VK Type 20: Body ported (A, B port top ported) Applicable solenoid valve VK3120M5 VK312001 VK332M5 VK33201 How to Order A port: Rc 1/8, M5 x 0.8 VZ VV5K3 20 05 A, B port Rc 1/8, M5 x 0.8 VK3120 Thread type VF VK332 Valve stations Nil 00F 00N 00T Rc 01 1 station Applicable blanking plate assembly VK3000-7-1A VFR G NPT 20 20 stations R port:

Note 3) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. To combine a pressure center valve and the A and B port pressure reduction of an interface regulator, use the ARBF3000, 4000, or 5000 model.

Align carefully when connecting to a load having an external guide mechanism. Mechanically jointed rodless cylinders can be used with a direct load within the allowable range for each type of guide, but careful alignment is necessary when connecting to a load having an external guide mechanism. As the stroke becomes longer, variations in the center axis become larger.

Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.) There may be the case it will vary substantially depending on an ambient environment. (n 2) 2 20 + 55 D-A59W 30 (n = 2, 4, 6, 8 ) Note 1) (n 2) 2 20 + 40 D-Z7/Z80 20 (n = 2, 4, 6, 8 ) Note 1) D-A5/A6/A59W cannot be mounted to 40, 50.

Fittings & Tubing Air Cylinders Rotary Actuators 1 8 For 8, 5/16" Applicable tubing O.D.: 6, 1/4" (A, B port) One-touch fitting (Pitch) (Pitch) 9 18 P = 17.5 9 18 P = 17.5 (A, B port) 1/8 7.5 23 7.5 23 B B B B A A A A P = 17.5 21 (Pitch) L2 L1 5 + 13.8 15.2 + (4.9) 5.4 7.2 68.2 100.3 [102.5] (For mounting) 4 x 4.5 27.8 20 139.6 [144] 127 [131.4] 20 20 37.7 66.8 P EB EA B B B B B 100.6 A A

Note 1) R block valve is mounted in the blocking position when ordering an individual EXH spacer incorporated with a manifold. When separately ordering an individual EXH spacer, separately order a R block valve.

Select an option symbol by the "Applicable Fluid Check List" p.4.0-7 for a special fluid outside of standard.

model which will provide a gripping force 10 to 20 times the weight of the work piece.

HRS 100/150 HRS 100/150 Applicable model Dimension [mm] A B C HRS100/150-A-20/40-A 830 302 1552 HRS100/150-W-20/40-A 570 401 1353 C HRSH 090 HRSH 118 HRSE A B Option symbol With Earth Leakage Breaker B HRZ HRZD HRS 20 B With earth leakage breaker HRW A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.

The rotation range under the adjustment of an angle at 60 is indicated below. The rotation range under the adjustment of an angle at 60 is indicated below. e g n R a o r t e a n ti g o o ti n n a a r t a o r n R g n e o ti a Note) If it is pressurized by the port indicated with the arrow, the shaft rotates in the clockwise direction.

Without air cushion With air cushion Air-hydro 50 P694020-20 P694020-21 P694020-23 63 P694030-20 P694030-21 P694030-23 80 P694040-20 P694040-21 P694040-23 100 P694050-20 P694050-21 P694050-23 Corresponding parts u, o, !0, !3 are included as a set. u, o, !0, !3, @3 are included as a set. u, o, !0, !3 are included as a set.

When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 2. Intermediate stopping. When a 3 position closed center valve is used to stop a cylinder at an intermediate position, accurate stopping of the piston in a predetermined position is not possible due to the compressibility of air.

A A A A A A A 120 <126.9> (7.5) (12) P = 16 41 23 C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting 6.5 126 80 C10 [1(P) SUP port] C10: 10 One-touch fitting Dust-tight, Water-jet-proof 2 L n Dimensions Formula L1 = 16n + 118.5, L2 = 16n + 131 n: Station (Maximum 20 stations) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L1 L2 (L3) (L4) 150.5

D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.