Search Results "HRSH200-AN-20-A"

Without air cushion With air cushion Air-hydro 50 P694020-20 P694020-21 P694020-23 63 P694030-20 P694030-21 P694030-23 80 P694040-20 P694040-21 P694040-23 100 P694050-20 P694050-21 P694050-23 Corresponding parts u, o, !0, !3 are included as a set. u, o, !0, !3, @3 are included as a set. u, o, !0, !3 are included as a set.

When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 2. Intermediate stopping. When a 3 position closed center valve is used to stop a cylinder at an intermediate position, accurate stopping of the piston in a predetermined position is not possible due to the compressibility of air.

A A A A A A A 120 <126.9> (7.5) (12) P = 16 41 23 C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting 6.5 126 80 C10 [1(P) SUP port] C10: 10 One-touch fitting Dust-tight, Water-jet-proof 2 L n Dimensions Formula L1 = 16n + 118.5, L2 = 16n + 131 n: Station (Maximum 20 stations) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L1 L2 (L3) (L4) 150.5

D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

A Series MGC 20 to 50 SZ + Stroke B D port C port A, B port B port A C port A port D port A View A-A GD GD Front mounting flange SB + Stroke B SA + Stroke A ZZ + Stroke A + Stroke B Bracket mounting With R Without R Stroke A stroke Stroke A + Stroke B ( ) Bore size (mm) W1 W2 SB SA GD ZZ GC SZ availability 30 30 Up to 200 96 50 9 176 21 20 35 st or more 89 110 30 30 96 50 9 183 21 25 60 st

x Width 925 x Depth 955] HRS150-W -20-A 459 [208] HRS150-A-20 A> 4.

combination of a switch unit and an angle adjuster.

an auto switch mounting screw, use a watchmakers screwdriver with a grip diameter of 5 to 6 mm.

Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.

Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

For a product without an external stopping mechanism, if a directional control valve is closed to keep the air pressure in the product, in an attempt to stop the product at midpoint, it might not be possible to maintain that stopped position due to an air leakage. As a result, it could pose a hazard to humans and cause damage to machinery and/or equipment.

In such a case, it is necessary to use the digital pressure switch ZSE10 or ZSE30A with a fine smallest settable increment or a flow switch for flow rate detection. Note) A vacuum generator with a large suction capacity will not be detected properly, so an ejector with an appropriate capacity must be selected. Since the hysteresis is small, vacuum pressure must be stabilized.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as valves.

Mineral oil A C A A A A 18 Sodium hypochlorite (2%, Room temperature) A C A D D B 19 Sodium chloride A A A A B 20 Carbon dioxide A A A A A A 21 Natural gas A A A A A A 22 Boric acid A B A D A B 23 Unless noted otherwise, the solution concentration is in a saturated state.

A wiring example of multiple controllers (3 pcs.) connected to an upper level device is shown below.

LEM LEM A-A 3 3 A LEY 4 x 5.5 LES Counterbore diameter 9.5, depth 5.4 Stroke adjuster LEPY LEPS Workpiece mounting center line 69 10.2 66 10 LER B 44 LEH T-slot for mounting Slot for auto switch A Stroke + 160 Stroke + 140 10 17 17 Stroke adjuster LEY -X5 60 11LEFS 11LEJS 102.3 (102) 0.3 (93) 20 20 65 20 28 25A27.3 (28) 27 20 LEC Motor cable length 300 139 LEC S 7.5 Note 1) [ ] for when

For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

W: 13 [kW] HRZD W Efficiency Power supply output VI: 8.8 [kVA] Q = P = Q = P = V x I x Power factor HRW In this example, using an efficiency of 0.7: In this example, using a power factor of 0.85: 5.1 0.7 HECR = = 7.3 [kW] = 8.8 [kVA] x 0.85 = 7.5 [kW] Cooling capacity = Considering a safety factor of 20%, HEC Cooling capacity = Considering a safety factor of 20%, 7.3 [kW] x 1.2 = 8.8 [kW]