Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Bracket, Lead Wire Length: 1000mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Bracket, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Bracket, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Bracket, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Bracket, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: 1000mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Average suction flow rate V x 60 T1 V x 60 T1 Q = Q = + QL T2 = 3 x T1 T2 = 3 x T1 Q : Average suction flow rate /min (ANR) V : Piping capacity () T1 : Arrival time to stable Pv 63% after adsorption (sec.) T2 : Arrival time to stable Pv 95% after adsorption (sec.) QL : Leakage at work adsorption /min (ANR) 2.
3 @8 !9 @0 @1 @2 @3 @4 @5 t u !4 !5 @7 y !6 !7 #0 #3 !1 @9 r q #1 #7 @6 o Component Parts Part Name Qty Remarks Item Part Name Qty Remarks Item q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 !
Example) 26NW 01 11 21 31 41 q w e w q Note 3) Only adjusting spring of regulator is different from standard specification. Note 4) Without valve mechanism. q q q w w w e (1) Numbers in . indicate order of constructtion of equipment from left hand side (the upper stream side) from a view of front side. Ex.)
Effective thread depth 3 Model A B C D E F G Vacuum inlet direction q Pad dia.
100 88 196 96 83 110 114 11 3 117 90 235 131 102 130 134 11 3 154 108 300 112 153 180 190 11 3 200 138 315 Note 1) Dimension E applies when heater option is included.
Product Precautions 14 JSY1000/3000/5000 Series Valve Construction Rubber Seal 2-position double 2-position single q e r w q e r w 5 (EA) 4 (A) 3 (EB) 2 (B) 1 (P) 2-position single 2-position double (A)4 2(B) (A)4 2(B) 3(EB) (EA)5 1 3(EB) (EA)5 1 (P) (P) 4-position dual 3-port valve 3-position closed center/exhaust center/pressure center q e r w q e r w 3-position closed center 3-position