SMC Corporation of America
Elite Part Number Search
Search Results "PF2D520-13-1-C"

N.C. 3 2 1 300 13 16 5.5 2 x 2.8 UL1007 AWG22 4.5 16.5 For LVM12R 57 2 x 2.7 Mounting hole Push type Manual override N.O. N.C. 3 2 1 N.O.

N.C. 3 2 1 300 13 16 5.5 2 x 2.8 UL1007 AWG22 4.5 16.5 For LVM12R 57 2 x 2.7 Mounting hole Push type Manual override N.O. N.C. 3 2 1 N.O.

/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3 36.3 N7 1/4 10.3 8.3 PFM7-01/02--X694 PFM7S-01/02--X694 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 13 11 17 13 39

Tubing size Symbol 03 04 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 Body class Tubing O.D. 1/8", 3 4 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 Body class 1 Symbol 1 2 3 4 5 Body class 1 2 3 4 5 Type of part Symbol U B N Type of part Nut & Insert bushing Insert bushing Nut 2 3 4 5 505 Applicable Fluids Material and fluid compatibility check list for High

Approx. 1.1 mm Insulator Colours Brown, blue, black, white Sheath Finish O.D. 4 -53No.PF-OMX0007-A Characteristics data Flow rate/Analogue output 0 L/min A 2 B 0 L/min C 2 D Voltage output (1 to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 3 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range *4 Maximum value of rated flow range PF3A701H 10 L

Allowable kinetic energy E max. : Table 1 Possible to use by E=0.0181 Load rate of moment Wa=W max. Calculate allowable load Wa(N). Wa=112=12 =1 W max.=12 1=2/12=0.167 Allowable load coefficient : Graph 1 Calcurate load rate (1) of moment.

Q = m x C x (T0 Tt) it = r x V x C x iT it = 1 x 20 x 4.2 x 103 x 12 900 = 1120 [J/s] 1120 [W] Q = m x C x (T0 Tt) it x 860 = c x V x 60 x C x iT it x 860 Cooling capacity = Considering a safety factor of 20%, 1120 [W] x 1.2 = 1344 [W] = 1 x 20 x 60 x 1.0 x 103 x 12 Thermo-chiller Q x t: Heat capacity [kJ] 15 x 860 1120 [W] 20C Water bath Cooling capacity = Considering a safety factor

Work piece mounting reference plane Rc 1/4 Vacuum suction port Rc 1/4 Vacuum suction port 80 Stroke + 115 (table movement range) 7.5 194 (249) 41 46 58 2-T-slot 1 57 65 69 90 95 9.3 44 40 (T-slot pitch) 2-T-slot 2 Stroke + 350 (405) 17 28 23 (78) 40 36 Body mounting reference plane 3-5H10 depth 5 3.3 5.8 1.7 5.3 T-slot 1 dimensions (switch groove) 11.5 45 27 (82) 40 80 Stroke + 145 9.4 4.5

B Q L2 L3 L4 L5 L6 L1 H 1(P) 2(A) C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-01S-M5 VHK-M5-M5 11 1.2 26 23 11 3.5 41 18 54 51 11 M5 M5 M5 VHK-B1A 44.5 14.5 1 27 22 16.5 26 2.0 2.0 29.1 16.5 29 29.1 61.6 58.2 1 8 11 3.5 41 8.6 1.2 13 18 13 VHK-B1A 44.5 14.5 1 27 22 16.5 26 32.6 16.5 VHK-01S-01S 1 8 1 8 30 57 32.6 65.2 VHK-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62

XGT 3 1 2 50336 1 C O 1:FKM 2:Kalrez R 4079 Kalrez R DuPont Performance Elastomers 50336 50mm 336mm 2: 3: 1:1 3:300mm A :0.5m D-A93 C 6 (C016 30C006 100 12:AMP ) (2 ) F 9 D CDE-9PF05 5 - 3. 6 - 3-1 1AB 23 2 3 19 2A 21 23 2B 1B 2C 2 2 3 19 3-2 1A 1B 26 8 9 22 13 12 18 9 27 12 13 18 9 18 , 21O 5 6 7 ASSY O 4 3-3 2A2B CLOSEOPEN 8 9 9 13 12 18

e p S h c t i w S t a o l F n o i t p i r c s e D 2 ~ 1 0 1 4 S I y t i c a p a C W 5 1 : C D , A V 5 1 : C A e g a t l o V V 0 5 2 C D , V 0 0 1 C A e r u s s e r P f o o r P ) a P M ( g i s p ) 5 . 1 ( 0 2 2 ) a P M ( g i s p e r u s s e r P . r e p O . x a M ) 0 . 1 ( 0 5 1 a i d e M l i O , r e t a W e r u t a r e p m e T d i u l F d n a t n e i b m A ) C 0 6 ~ 5 ( F 0 4 1 ~ 0 4 l e

Ambient and fluid temperature (C) 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25 AR40 AR40-06 AR50 1/4, 3/8 AR30 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 AR60 Model AR20 AR40 AR40-06 AR50 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 AR60 Port size 1 Port size 1 30 AR X430 03 BG 30 AR X425 03 BG For high/low temperature Option/Semi-standard: Select one each

Elbow Universal 2 3 Metric size Inch size 3.2 23 01 1/8" 04 06 08 10 12 03 05 07 09 11 13 4 5/32" 6 3/16" Control 8 1/4" Meter-out Meter-in 0 1 10 5/16" 12 3/8" Use 1/8" tube. 1/2" M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 01 02 03 04 U10/32 N01 N02 N03 N04 Needle Valve/Flow Characteristics AS1201FG, AS1211FG AS2201FG-

+ COM (For COM specifications, specify them separately.) 1 3 5 6 VZ1120MOZ-M5 Applicable valve model Rated voltage 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Note 1) Value at manifold base mounted, single operating Note 2) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.

Regenerative error (Note 1) (Note 1) (Note 1) Alarms AL.31 1 0 1 Overspeed AL.32 1 0 0 Overcurrent AL.33 0 0 1 Overvoltage AL.35 1 0 1 Command pulse frequency alarm AL.37 0 0 0 Parameter error AL.45 0 1 1 Main circuit device overheat (Note 1) (Note 1) (Note 1) AL.46 0 1 1 Servo motor overheat (Note 1) (Note 1) (Note 1) AL.47 0 1 1 Cooling fan alarm AL.50 0 1 1 Overload 1 (Note 1) (Note 1)

Bit offset Item Notes 0 Accumulated flow SW1 0: OFF 1: ON 1 Accumulated flow SW2 0: OFF 1: ON 2 Flow rate SW1 0: OFF 1: ON 3 Flow rate SW2 0: OFF 1: ON 4 Temperature SW1 0: OFF 1: ON 5 Temperature SW2 0: OFF 1: ON 6 Pressure SW1 0: OFF 1: ON 7 Pressure SW2 0: OFF 1: ON 8 Flow rate unit 0: L 1: ft3 9 Flow rate criteria 0: STD 1: nor 10 Flow diagnosis 0: Normal 1: HHH 11 Temperature diagnosis

8 words/8 words) Up to 42 (when 1 station is occupied by 1 driver), Up to 32 (when 2 stations are occupied by 1 driver), when there are only remote device stations.

M18 x 190 l M18 x 200 l 190 200 C (D) Q2B18075DC C (D) Q2B20075DC M18 x 215 l M18 x 225 l 215 225 C (D) Q2B180-100DC C (D) Q2B200-100DC 3 Series CQ2 Compact Cylinder Double Acting: Single Rod Dimensions (mm) Dimensions are the same with and without auto switches. 1in = 25.4mm 180 2 x 4-31.5 depth of counter bore 26 29 29 2-Rc 1/2 (port size) 40 52 52 4-19 through 162 204 4.5 3 Note 1) Flat