SMC Corporation of America
Elite Part Number Search
Search Results "PSE560-B2-C2"

Please contact us for the latest version.sales@ocaire.com, GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, C2, AR 1/8INCH KIT/ACCESSORY, .17600 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores, ?

Please contact us for the latest version.sales@ocaire.com, GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, C2, AR 1/8INCH KIT/ACCESSORY, .26455 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores, ?

(full span), GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, C2, AR 1/8INCH KIT/ACCESSORY, .24150 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores, ?

Please contact us for the latest version.sales@ocaire.com, GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, C2, AR 1/8INCH KIT/ACCESSORY, .23715 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores, ?

LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C Power Connector Cable LC6D Connector Cable Model LC6-1-C2--X252 Model LC6-1-C1--X258 Electric actuator LC6D Electric actuator LC6C Cable length 1 1m 3 3m 5 5m Cable length 1 1m 2 2m 5 5m Power connector Cable length: 1 to 5m Motor cable b Cable length: 1 to 5m 13 12 11 10 6 5 4 3 2 1 a Motor cable 7 13 12 11 10 9 8 6 5 4 3 2 1 Switch cable 14 15 16 17

LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C Power Connector Cable LC6D Connector Cable Model LC6-1-C2--X252 Model LC6-1-C1--X258 Electric actuator LC6D Electric actuator LC6C Cable length 1 1m 3 3m 5 5m Cable length 1 1m 2 2m 5 5m Power connector Cable length: 1 to 5m Motor cable b Cable length: 1 to 5m 13 12 11 10 6 5 4 3 2 1 a Motor cable 7 13 12 11 10 9 8 6 5 4 3 2 1 Switch cable 14 15 16 17

Kl Ml How to Order Hl N 04 DM 6 Dl Number of connecting tubes MS 6 12 6 12 Accessories (optional) 1 cover (One side) 2 covers (Both sides) C1 C2 Tl Style P S Multi-connector Plug side Tube material Nylon Soft nylon Polyurethane N Socket side NU Tube O.D. 4mm 6mm 04 06 2.1-66 Series DM Dimensions/DM6,12 DM6 Panel mounting hole (with the cover at socket side) Panel mounting hole DM12 Panel

Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: PHC (Flat Ribbon Cable, IP20, 10 Pins, Compact Type), Connector Entry Direction: 2 (Lateral), Valve Stations: 2 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C2 (ø2 One-touch Fitting), Mounting: D (DIN Rail Mounting)

Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: PHC (Flat Ribbon Cable, IP20, 10 Pins, Compact Type), Connector Entry Direction: 2 (Lateral), Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C2 (ø2 One-touch Fitting), Mounting: D (DIN Rail Mounting)

Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable), Connector Entry Direction: 2 (Lateral), Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C2 (ø2 One-touch Fitting)

Series: 1 (JSY1000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 2 Stations, P,E Port, SUP/EXH Assembly: U (Internal Pilot, U Side, 2 to 10 Stations), A,B Port Size: C2 (ø2 One-touch Fitting)

Actuation: 1 (2 Position Single), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: R (External Pilot), Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: NZ (w/Light Surge Voltage Suppressor, Negative Common), Manual Override: Non-locking Push Type, A,B Port Size: C2

Actuation: 5 (3 Position Pressure Center), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: C2

Model: 10 (Side Ported), Number of Cores - Lead Wires: L1 (34 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 10 Stations, P, E Port Locations: U (U Side), SUP/EXH Block: Internal Pilot, A, B Port Size: C2 (ø2 One-touch Fitting), Mounting: A (DIN Rail Mounting, Name Plate w/Station Number)

mb= n, t r a+b l l ta2+c2 i a ' Ti+l 2 . ^ 2 12 ho'oo#" ' 1 J = n y r = m " . * * ' o . F Fig. 6.23 Formulae for the moment ol inertia of various body shapes To define this energy we need to know the inertia of the rotating mass.

Accessory (option) Number of connecting tubes Nil C1 C2 No Cover single side 1 pc. Cover both sides 2 pcs. 6 12 6 12 How to Use Caution Configuration Disassembly Tube O.D. Nil P S Multi-connector Plug side only Socket side only 23 04 3.2mm 4mm (1) Loosen clamp ring A and disassemble the connector into the plug case and socket case.

GEnlarge cover and mount cover onto mounting area. 3 1 C 2 4 5 Cover mounting area Cover How to Order N 04 DM 6 Number of connecting tube 6 12 6 12 Accessories(optional) 1 cover(One side) 2 covers(Both sides) C1 C2 Type Tube material P 12 Multi-connector Plug side Socket side N Nylon Soft nylon Polyurethane NU Tube O.D. 4mm 6mm 04 06 70 Series DM Multi-connector Dimensions (mm) DM6 Panel

LC6D Connector Cable LC6C Power Connector Cable Model LC6-1-C1--X258 Model LC6-1-C2--X252 Electric actuator LC6D Electric actuator LC6C Cable length 1 1m 3 3m 5 5m Cable length 1 1m 2 2m 5 5m Power connector Cable length: 1 to 5m Motor cable b Cable length: 1 to 5m 13 12 11 10 6 5 4 3 2 1 a Motor cable 7 13 12 11 10 9 8 6 5 4 3 2 1 Switch cable 14 15 16 17 18 Interface cable 7 9 8 Power cable

(Nm) L(mm) MHM-16D M3x0.5 0.63 6 MHM-25D M4x0.7 1.5 8 MHM-32D M5x0.8 3 10 MHM-50D M6x1 5.2 12 (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 -7- 2-3. 40 2-4. () 5 5 P-01-11 -8- 2-5. 1.52 2-6. 1 ()ISO VG320 (SDS) -9- 2-7. 1) 1) 2) 3) 12mm -10- 2 C3 C1 C2: C3 D-M9V D-M9WV D-M9AV D-M9 D-M9W D-M9A D-P3DWA A B E G A B E G L A B E G L D F H MHM-16D 9.1 9.1 5.6 4.6 8.1 12.8 11

KQSY10-C4-X1336 (JSY1000) KQSY11-C6-X1336 (JSY1000) KQSY30-C8-X1336 (JSY3000) KQSY50-C12-X1336 (JSY5000) * It is not possible to replace C2 or C4 fittings with C6 fittings for the JSY1000 series. * Refer to page 18 for One-touch fitting, clip, and port plate part numbers. 15 No.JSY1000V-OMW0004-A JSY1000/3000/5000 series Specific Product Precautions 7 Be sure to read this before handling.