(Tolerance 30%) OUT(+) Brown(Red) OUT() Blue(Black) 46 Medium Duty Air Cylinder Series NCA1 Specifications PLC: Programmable Logic Controller Grommet D-F59F Auto switch model number The output signal can be detected in an unsteady detecting area.

D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+

(Assuming approximately 30% dispersion.) There may be the case it will vary substantially depending on an ambient environment.

Refer to page 30 for the noise filter set. Refer to the LECA Operation Manual for installation.

This control is not for synchronizing the position of the main axis and slave axis. 10 10 Current position Current position Origin 0 0 Origin 10 20 30 40 50 Axis 1 10 20 30 40 50 Axis 1 For 3 Axes JXC92 Series For 4 Axes JXC73/83/93 Series p. 3 p. 4, 5 VParallel I/O/ V Type V Width: Approx. 38% reduction Type V Width: Approx. 18% reduction 78 47 mm shorter 140 30 mm shorter JXC73/83 JXC92

Tightening Torque when Piping Connection thread Proper tightening torque [Nm] Rc 1/4 12 to 14 Rc 3/8 22 to 24 Rc 1/2 28 to 30 Rc 3/4 28 to 30 Rc 1 36 to 38 4. Piping to products When piping to products, avoid making an error of supply port etc., by referring to the operation manuals. 5.

20 (3/4B) 500 3 210 640 741 764 30 25 (1B) 210 645 750 772 30 40 A Elements Sintered Metal/Fiber Nonstandard elements of the FQ1 series can also be used commonly.

In this case, a DIN rail which is approx. 30 mm longer than the manifold with the specified number of stations is attached. When DIN rail is unnecessary (DIN rail mounting brackets only are attached.) Indicate the option symbol, -D0, for the manifold part number.

Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For

For DC : SY100 30 4A For 100 VAC : SY100 30 1A Pin Groove Cover For 200 VAC : SY100 30 2A For other voltages of AC : SY100 30 3A Pin Groove Cover DC polarity indication Lever SY100 30 A Without lead wire : with connector and 2 pcs. of sockets only -+ Socket Lead wire Connector Lead wire length How to Order Indicate part numbers of the valve without connector and the required connector assembly

4.5 6.5 40 2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 43.9 5.4 15.4 55 2.3 27.3 36.5 17.5 6 AR25-A 1/4, 3/8 1/8 53 70.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 44.3 5.4 15.4 55 2.3 30.3 36.5 17.5 6 AR30-A 1/4, 3/8 1/8 53 83.5 27 28.5 M45 x 1.5 28.5 37.5 65 37.5 66 41 36 46 6.5 24 65 2.3 32.5 45.5 22.5 7 AR40-A 1/4, 3/8, 1/2 1/8 70 100 33.5

Tightening torque: HEC006--22 to 24 Nm HEC012--28 to 30 Nm Drain -12 to 14 Nm 3) A plug is mounted on DRAIN for recirculating fluid. When the piping for drain is connected, remove this plug beforehand. Be sure to arrange the piping on the drain to exhaust the constant temperature recirculating fluid in the unit at the maintenance.

Selection conditions Mounting: Horizontal Bearing type: Slide bearing Distance between plate and load center of gravity: 50 mm Maximum speed: 200 mm/s Load mass: 2 kg Stroke: 30 stroke Find the point of intersection for the load mass of 2 kg and 30 stroke on graph (17), based on horizontal mounting, slide bearing, the distance of 50 mm between the plate and load center of gravity, and the

For details, refer to 3 point preset counter/CEU1 on page 10-12-30, and Multi counter/CEU5 on page 10-12-27 respectively.

x 3 x 60 = 2736g/h. 6 7 8 3 1 2 3 4 5 Dew point conversion chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric pressure dew point C 8 Series IDUS/IDFS Safety Instructions These safety instructions are intended to prevent a hazardous situation and/

50% 70% 10% 30% 50% SY 150 300 Stroke (mm) 70% Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke

(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Output for display unit Output Note 2) specifications Voltage output 1 to 5 V Linearity: 5% F.S. or less; allowable load resistance: 100 k or more.

voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) Nil A Standard: DC specifications Standard: AC specifications With power saving circuit (24, 12 VDC only) SY100-30-2AFor 200 VAC: T For other voltages of AC: SY100-30-3APower saving circuit is not available in the case of W type.

x 3 x 60 = 2736g/h. 6 7 8 3 1 2 3 4 5 Dew point conversion chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric pressure dew point C 8

A Graph 1 Graph 2 120 60 110 B 100 50 C P1 63 63 90 80 40 70 Regulator Circuit C Load weight (kg) Load weight (kg) P2 60 30 50 50 A 50 Regulator valve 40 20 40 40 30 B 32 32 20 10 C P1 10 0 0 0.4 0.3 0.3 0.5 0.6 0.7 Operating pressure (MPa) 0.4 0.5 0.6 0.7 Operating pressure (MPa) Selection example Confirmation of allowable kinetic energy Selection conditions: Transfer direction: Vertical