(1/4), Thread: F (G), Bracket: F (Bracket)
(1/4), Thread: F (G), Bracket: F (Bracket)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Model: 54 (VP500), Body Type: 2 (Body Ported), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (3/8 Body Ported; 1/4 Base Mounted), Thread: F (G), Actuation: A (N.C.; Normally Closed), Bracket: F (Bracket)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 4 (220 VAC, 50/60 Hz, Semi-Standard), Electrical Entry: H (600mm Lead Wire), Light_Surge Voltage Suppressor: S (with Surge Voltage Suppressor, Grommet Type Only), Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 3 (110 VAC, 50/60Hz, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket), CE Compliant: Q (CE-Compliant)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 5 (24 VDC), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor, DIN Terminal Type Only), Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 5 (24 VDC), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket), CE Compliant: Q (CE-Compliant)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 5 (24 VDC), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)
Body Type: T (Body Ported), Valve Option: W (Energy-Saving Type, Vacuum Specification Type, Semi-Standard), Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 5 (24 VDC), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor, DIN Terminal Type Only), Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 5 (24 VDC), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 5 (24 VDC), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor, DIN Terminal Type Only), Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 5 (24 VDC), Electrical Entry: H (600mm Lead Wire), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 5 (24 VDC), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: S (with Surge Voltage Suppressor, Grommet Type Only), Port Size: 02 [1/4 (8A)], Thread Type: F (G), Bracket: F (with Bracket)