D-A73H LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 Resistor Reed switch Zener diode Weight OUT () Blue Blue (g) D-A72H D-A73H D-A76H D-A80H Auto switch model D-A76H 10 10 11 10 0.5 Lead wire length (m) 47 47 52 47 3 DC (+) Brown 77 5 LED (+) Resistor Load Reed switch DC power supply OUT Black Reverse current prevention diode Dimensions () DC () Blue D-A7H, D-A80H D-A80H
D-A73H LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 Resistor Reed switch Zener diode Weight OUT () Blue Blue (g) D-A72H D-A73H D-A76H D-A80H Auto switch model D-A76H 10 10 11 10 0.5 Lead wire length (m) 47 47 52 47 3 DC (+) Brown 77 5 LED (+) Resistor Load Reed switch DC power supply OUT Black Reverse current prevention diode Dimensions () DC () Blue D-A7H, D-A80H D-A80H
(l/min(ANR)) Air consumption N (l/min(ANR)) 80 80 Air consumption N (l/min(ANR)) Suction flow rate N(l/min(ANR)) 80 80 Suction flow rate Vacuum pressure (kPa) Vacuum pressure (kPa) Vacuum pressure (kPa) Vacuum pressure (kPa) 67 10 67 67 10 67 Air consumption 53 53 53 53 40 40 40 40 5 Suction flow rate 5 27 27 27 27 Vacuum pressure 13 13 13 13 0 0 0 2 4 6 8 10 12 0 0.1 0.2 0.3 0.4 0.5 0.6
VE Ozone resistant VY1 IRM 10 3 G 4 For High/Low Temperature Environments Set pressure and quantity Stations G 0 1 2 0.2 MPa setting 1 to n pcs. 0.4 MPa setting 1 to n pcs. 0.8 MPa setting 1 to n pcs. 2 2 stations Standard model no.
14 10 14 12 16 20 24 27 38 41 51 37 41 50 41 45 57 42 43 53 72 78 KA 4 2.5 1.8 1.6 10 8 13.5 5 4 3 KQG2 2.3 2.6 Applicable tubing L1 M 6 4 6 10 10 15 5.8 3.3 KG H1 12 d 8 6 KFG2 KFG2 5.3 12 14 17.4 6.6 16 22.2 A L2 23 H2 MS 25.6 10 7.5 6.8 26 Connection thread 27.5 15 17 20.9 7.6 KKA 27 25.6 10 8 7.3 30 KP 27.5 27 25.6 12 9 8 LQ 35 27.5 16 17 23.5 8.5 34 MQR 25.6 12 10 9 44 27.5 31 32.9
14 10 210.5 200 181 15 11 223 212.5 191.5 16 12 235.5 225 202 17 13 248 237.5 212.5 18 14 248 237.5 223 12.5 15 260.5 250 233.5 13.5 16 273 262.5 244 14.5 L1 L2 L3 L4 External pilot manifold L: Dimensions n: Stations (n1 + n2) L n 2 135.5 125 107.5 14 3 148 137.5 118 15 4 160.5 150 128.5 16 5 173 162.5 139 17 6 173 162.5 149.5 12 7 185.5 175 160 13 8 198 187.5 170.5 14 9 210.5 200 181 15
) CCW : CW : . 1) (2mm/) 2 1 CCW CW 2 3 OFF(ON) -28- (=) P.25 =02mm) =0 a) CCW 50mm =0() =10 50mm CCW CW 0 10 20 30 40 50 [mm] 50mm CCW CW 10 20 30 40 50 60 [mm] b) CW )50mm =0() =10 =-10 50mm CCW CW -50 -40 -30 -20 -10 0 [mm] 50mm CCW CW -40 -30 -20 -10 0 10 [mm] 50mm CCW CW -60 -50 -40 -30 -20 -10 [mm] -29- 4/ A 50mm () 5m 5m 10% 15m 20% -30- 5./ 5.1 (LEC ) ,,
1 Auto Switch Guide Reed Switches/Solid State Switches For Rotary Actuators (Air Grippers) Applicable Auto Switch Auto switch mounting Applicable air grippers Applicable rotary actuators Auto switch model Electrical entry Page Type CRB2 Size Size CRBU2 30 50-100 10/15 20-40 10-40 32/40 1/3 7/20 10-200 05/1 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB2 CDRBU2 CDRQ2MRQ
Contact protection box CD-P11 LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator
An example is shown below. direction + direction direction + direction 0 5 10 [mm] 0 5 10 [mm] This example shows the Target Position set at 10 mm. The table of the Card Motor moves to 10 mm from the origin position. 11.5 Relative positioning The Target Position is determined based on the current position.
100 14 10 29 20 71 16 110 M12 x 1.75 10 26 8 M26 x 1.5 131 212 100 to 750 Flange brackets and plug bolts are installed before shipment from factory.
.Communication setting screen 36.Contact output 46 Setting screen 10.
An over current (1) Check if there is noise Incorrect internal data processing of the product (Er0, 4, 6, 7, 8 or 9) error (Er1, 2) is displayed. interference (such as static electricity. (2) Check if the power supply voltage System error is in the range 24 VDC 10%. (Er0, 4, 6, 7, 8 or 9) is displayed. (2) Supply power in the range 24 VDC 10%.
1 I.{ 50 114 139 13 100 10 t 15 5 9 5.5 v 74 4.5 AMG25O 3/8 '152 13 1 1 3 6 10 '| 69 n '12 4 84 a 5 2 n Ai/lc350 1/2 144 16 145 s s '10 198 m 2 14 7 80 100 g 2.3 ANtG450 314 205 19 147 106 106 JO s 10 14 88 1 1 0 3.2 AMG55O 239 200 10 257 100 s 10 't6 102 130 m 10 4.5 AIVG&5O 1 112 291 c 253 r60 160 10 364 150 .10 20 1 1 s 136 180 4.5 2 48 a 348 220 ?
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
Lock Specifications Clamp Specifications Locking action Spring locking (Exhaust locking) Without shim With shim Clamp stroke 10 mm 0 0.5 Unlocking pressure 0.2 MPa or more 10 mm to 12 mm Lock starting pressure 1 pc.
Host STX 31H Setting data ETX Check sum CR 101 100 10-1 10-2 (H) (L) Thermo-con ACK CR
Rated pressure range Rated pressure range Rated pressure range Rated pressure range Rated pressure range 100 kPa to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa 101 kPa to 0 100 kPa to 100 kPa 0 to 100 kPa 0 to 1 MPa 101 kPa to 0 100 kPa to 100 kPa 0 to 1 MPa 0 to 2 kPa 101 kPa to 0 100 kPa to 100 kPa 0 to 500 kPa 0 to 1 MPa C O N T E N T S How to Order p. 7 Internal
d i a n a p o l i s, I N ROCHESTER, NY (716) 321-1300 Vacuum Pad Series ZP Replacement Parts: Pad unit (With lock ring/Without lock ring) Pad Unit/How to Order Lock Ring Unit/How to Order ZPL 1 X19 U N 10 ZP Applicable pad dia.