No. of connection tubes Plug Model Color of release button D Socket KDM10S-23 KDM10S-04 KDM10S-06 KDM10S-08 KDM20S-23 KDM20S-04 KDM20S-06 KDM20S-08 KDM10P-23 KDM10P-04 KDM10P-06 KDM10P-08 KDM20P-23 KDM20P-04 KDM20P-06 KDM20P-08 3.2 4 6 MS Irregular faces for engagement 10 Allen wrench (Nominal width across flats 4) T 8 3.2 Blue VMG 4 6 8 20 Clamp bolt Panel mounting 1.
Red (+) Insulation: Black () 0.3 mm2 4.1 51.2 48.5 (92) Cable type (TT) 52-SY9240 (R) -TT03 04 Max.10 L 217.6 (Lead wire length) Lead wire marking No.1 (+), No.2 () 0.75 mm2 (108.8) 21 ATEX Compliant Base Mounted Type Series 52-SY9000 Dimensions 29 30 3-position closed centre/exhaust centre/ pressure centre L plug connector (L) 17.5 52-SY9440 (R) -L03 04 3 5 123 51.2 86.5 Manual override
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 2 Stations, Voltage: 5 (24 VDC), Electrical Entry: L Plug Connector, Blanking Plate: B1 (1 set)
Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Suction Flow(l/min): 16, Electrical entry: L-type plug connector, Light/surge voltage suppressor: With light/surge voltage suppressor, Solenoid valve rated voltage: 24 V DC, Valve Type: N.O
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 Symbol B A Inch sizes Basic size With reducer 03 05 07 11 13 1/8" x 0.086" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" Note 1) Applicable fittings: LQ2 Note 2) For details of the applicable tubing sizes, refer to page 945.
KB 1 V Elbow module: KBV Elbow socket module: KBV T Connecting thread Tube O.D.
01 02 03 04 VPA342 542 742 Description Part no.
1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8 2 Speed Controller with One-touch Fitting Elbow Type (Metal Body) Series AS Flow Rate and Effective Area AS321-03 AS421-04 AS221-01 AS221-02 AS121-M5 Model Tubing O.D. 12 10 10 8 6 8 4, 6 6, 8 Controlled
(UL standard V-0) Applicable model: ASV310F, ASV410F, ASV510F Inch size Note) Elbow: M3, M5 only Port size AS 04 06 08 10 12 03 07 09 11 13 M3 M5 U10/32 01 02 03 04 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 With One-touch fitting Thread type ASP Brass parts are all electroless nickel plated.
Common exhaust: VV3P7-41Stations 1-04 (G) (E) (T) (D, Y) N.C.
KB 1 V Elbow module: KBV Elbow socket module: KBV T Connecting thread Applicable tube O.D.
Model Port size 4 6 8 10 12 ASD One-touch fittings for AS121-M5 AS221-01 AS221-02 AS321-02 AS321-03 AS421-04 M5 x 0.8 AS 1 8 R metal body specifications 1 4 R AS-FE 1 4 Uses flame resistant resin as standard. (UL standard V-0) R 3 8 R KE 1 2 R Note 1) : Brass parts are electroless nickel plated, provided as standard.
Model Description AMR3000 AMR4000 AMR5000 AMR6000 : E4-02 : E4-03 : E4-04 1 4 3 8 1 2 1 4 1 2 : E6-06 : E6-10 3 4 1 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (6) 3 8 3 4 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float style auto drain (Bowl assembly) IS1000-01 (Set at 0.4MPa) Compact pressure switch PT elbow (7) 135510 135613 Note 5) in the gauge part number (e.g.
To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.
The angle is 69 when any of the following auto switches are used: D-S99(V), D-T99(V), and D-S9P(V) 3.
Auto Switch Weights Unit: g (oz) Auto Switch Internal Circuits Lead wire length Model 3m 5m D-P5DWL 150 (5.3) 240 (8.5) Indicate "Z" at the end of the model number for 5m lead wire.
F.S. = 5[V] 1[V] = 4[V] 3[%F.S.] = 4 X 0.03 = 0.12[V] Detection Analog output voltage [V] Pressure indication [kPa] Switch The output error induced by the temperature change can be as much as 0.12[V]. 1.12 1 0.88 P3 0 Vacuum Pressure Rated pressure P1 P2 103 100 97 Pressure display = 100[kPa] Temperature characteristic = 3[%F.S.]
P V < 2 3 . 0 o C # 1 S V 3 0 . 0 o C M O D E R e m : 0 5.10.4 Circulating fluid set temperature The circulating fluid set temperature can be set by specifying the circulating fluid target temperature during Serial Remote mode.
The residual voltage of the diode is approximately 1 V. with the cords lead wires. Precautions Plug in and pull out the connector vertically without tilting to one side. Compatible cable Cord O.D.3.5 to 7 Reference 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306 DIN Connector Part No.
Breaker capacity 5A Sensitivity current 15 to 30mA L Option symbol With heavy duty auto drain A dryer with heavy duty auto drain (ADH4000-04) is installed instead of the float type auto drain (AD44).