Contents MHF2-12D MHF2-12D1 MHF2-12D2 Grease package part number Seal kit MHF12-PS MHF12-PS MHF12-PS 20, 21, 22 MHF2-D,D1 (12, 16, 20) GR-S-010 (10g) for guide MHF2-D2 (12) GR-L-005 (5g) for cylinder Contents MHF2-D2 (16, 20) Order No.
Refer to the Made to Order Specifications on page 20.
Bore size (Stroke (mm)) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Applicable Auto Switches/Refer to Best Pneumatics No. 3 for further information on auto switches.
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Series ZFB Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Metric size 3/16" 20 22 20 22 30 30 75 40 100 62 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 1/4" 1/4" Inch size (2) 3/8" 1/2" Specifications Fluid Air/Nitrogen Negative pressure 0.5MPa 0 to 60C (Non-freezing) 30m 0.15MPa Nylon/Soft Nylon/Polyurethane
Note 2) Voltage output 1% F.S. or less Approx. 1 k Analog output 2.4 to 20 mA 2.5% F.S. 4 to 20 mA 2.5% F.S.
Bore size (Stroke (mm)) 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 6 8 12 16 20 25 Functional option Standard With buffer With end lock Axial piping type With buffer and end lock With buffer, Axial piping type Nil F R (2) P FR (2) FP Adjuster option Note
M5 x 0.8 14 12.5 21.5 19 22 19 19 16 16 14 6 5 7.6 depth 6.5 81 72.5 86 77.5 91 82.5 96 87.5 101 92.5 106 97.5 116 126 100 88.5 93.5 103.5 108.5 135 145 40 36.5 110 98.5 113.5 9.5 depth 8 105 115 120 125 83 88 93 98 103 108 118 128 106 111 116 121 126 131 141 151 5.5 9 4.5 20 25 15.5 18 32 50 10 29 40.5 M8 x 1.25 9.5 depth 9 22 22 23 20 8 748
If foreign matter with a size of 20 m or more are likely to enter, install the particle filter. Filter Rc1 3 20m HRS-PF005 4 Flow meter Prepare a flow meter with an appropriate flow range. 5 Valve(Part of thermo-chiller) Rc3/4 Y-strainer Rc1/2 #40 Install either the strainer or filter. If foreign matter with a size of 20 m or more are likely to enter, install the particle filter.
L L 2 . 3 . 6 4 . 5 . 6 . 2 2-3. 1 2 Nm mm 16 5 20 M30.5 0.59 6 25 6 8 32 40 M40.7 1.4 8 10 50 63 M50.8 2.8 10 80 M61 4.8 12 100 M81.25 12 16 125 M101.5 24 20 3 P9P11 7 Nm mm MHSH(J)3-32DA,B M30.5 0.6 6 40DA,B M50.8 2.8 10 50DA,B M61 4.8 12 63DA,B M81.25 12 16 80DA,B M101.5 24 20 A J/ / 8 MHS2 Nm mm MHS2-16D M40.7 2.1 8 20D M40.7 2.1 8 25D M40.7 2.1 8 32D M50.8 4.3 10 40D M61 7.3
Screw torque (Nm) depth (mm) MHZJ2-10 M3 x 0.5 0.9 6 MHZJ2-16 M4x0.7 1.6 4.5 MHZJ2-20 M5 x 0.8 3.3 8 MHZJ2-25 M6x1 5.9 10 Max. tightening torque (Nm) Maximum screw-in Model No. Screw depth (mm) MHZJ2-10 M3 x 0.5 0.69 5 MHZJ2-16 M4x0.7 2.1 8 MHZJ2-20 M5 x 0.8 4.3 10 MHZJ2-25 M6x1 7.3 12 Max. tightening Model No.
Reference condition for volumetric flow: 101.3 kPa, 20 C, 65%RH The flow measurement which is converted at normal atmospheric pressure conditions at 20 C, 65%R.H. Standard condition (ANR) An output type that has only 2 conditions, ON or OFF. In the ON condition an indicator LED will turn on, and any connected load will be powered.
ZPGB30J-7A-X2 18 19 19 25 ZP2-B30J ZP3P 20 JT2 SF ZP3PG20JT2SF-7A-X2 21 ZP3P-20JT2SF-W ZP3PA-T1JT-7A-X2 ZP3P 20 JT2 SF M ZP3PG20JT2SF-M-7A-X2 21 ZP3P-20JT2SF-WM ZP3P 32 JT2 SF ZP3PG32JT2SF-7A-X2 48 ZP3P-32JT2SF-W ZP3PA-T2JT-7A-X2 ZP3P 32 JT2 SF M ZP3PG32JT2SF-M-7A-X2 48 ZP3P-32JT2SF-WM ZP3P 20 JT5 SF ZP3PG20JT5SF-7A-X2 23 ZP3P-20JT5SF-WG ZP3PA-T1JT-7A-X2 ZP3P 25 JT5 SF ZP3PG25JT5SF-7A-X2
A M Weight (g) D L Nylon Urethane 2.1 2.3 3.6 7 3 3.5 5.2 KGR04-08 KGR04-06 4 6 8 10 4 8 10 12 10 12 12 16 16 17.5 18 18.5 21 34.5 36.5 39.5 10.4 16 5.6 5.6 KGR04-10 12.8 KGR06-04 KGR06-08 KGR06-10 KGR06-12 KGR08-10 KGR08-12 KGR10-12 KGR10-16 KGR12-16 4 4 37 37 39.5 42 41 42 42 50.5 50.5 12.8 17 6 18.5 13.1 13.1 15.2 20 4.5 5.1 33 8 15.2 18.5 20 26.1 18.0 32.8 (29.5) 20 25.5 25.5 17 20.9
20 SUP=0.2MPa SUP=0.2MPa 10 10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
Model determination 61 Series REBR Model Selection 2 Design Parameters 1 Selection Method REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable
A M Weight (g) L D Nylon Urethane 2.1 2.3 3.6 7 3 3.5 5.2 KGR04-08 KGR04-06 4 6 8 10 4 8 10 12 10 12 12 16 16 17.5 18 18.5 21 34.5 36.5 39.5 10.4 16 5.6 5.6 KGR04-10 12.8 KGR06-04 KGR06-08 KGR06-10 KGR06-12 KGR08-10 KGR08-12 KGR10-12 KGR10-16 KGR12-16 4 4 37 37 39.5 42 41 42 42 50.5 50.5 12.8 17 6 18.5 13.1 13.1 15.2 20 4.5 5.1 33 8 15.2 18.5 20 26.1 18.0 32.8 (29.5) 20 25.5 25.5 17 20.9
Symbol Stations 02 20 20 2 stations 20 stations Specify the valve stations not exceeding the maximum stations. SUP/EXH block fitting spec.
Do not use a cable longer than 20 m. Wire the DC(-) line (blue) as close as possible to the power supply.
Bolt size 10 4 M4 or larger 15 5 M5 or larger 20 6 30 8 M6 or larger Table 3 Fixed with a Holding Block (Refer to Fig. 6 and 7.) Fig.5 Size Shaft dia. Bolt size Plate thickness (t) 10 4 M3 or larger 2 or wider 15 5 2.3 or wider 20 6 M4 or larger 3.6 or wider 30 8 M5 or larger 4 or wider The plate thickness (t) in the table above indicates a reference value when a carbon steel is used.
Recommended tightening torque Unit: N m Thread size 1/8 1/4 3/8 1/2 3/4 1 Torque 3 to 5 8 to 12 15 to 20 20 to 25 28 to 30 36 to 38 (4) Before using an SMC fitting and S coupler, please refer to "Tightening the threaded portion of the connection thread" of the Fittings & Tubing Precautions. (5) Do not apply torsion or bending moment other than the weight of the product itself.