# 0 0 P R [CR] No. 1 0 0 0 0 0 1 1 # 0 0 P W [CR] No. 1 0 0 0 0 0 1 1 # 0 0 P W [CR] No. ):0,1,2,3,4 30 - # 0 0 F R [CR] No. # 0 0 F R [CR] No. + 0 1 2 3 4 5 # 0 0 F W [CR] No. + 0 1 2 3 4 5 # 0 0 F W [CR] No. 31 - # 0 0 S R [CR] No. # 0 0 S R [CR] No. 0 0 1 : 0.1(s) # 0 0 S W [CR] No. 0 0 1 : 0.1(s) # 0 0 S W [CR] No. )1 (0.1 )0 32 - # 0 0 O R [CR] No. # 0 0 O R [CR] No. 0

Lube Unit Mounting thread M12 Float switch mounting position J (Bracket mounting dimensions) Panel (Option) Bracket (Option) A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 43 10 57 51 16 67 77 85 90 100 283 296 424 424 476 4 3 135 345 460 145 90 150 480 20 430 470 175 87.5 30 62.5 1 1 1 2 615 615 682 419.2 209 4 1 250 125 33.2 33.2

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

K L M N P Q R S T Model VNC2-10A VNC2-15A VNC3-20A VNC4-25A 3 8 1 2 3 4 1 63 63 80 90 42 42 50 60 28 28 35 40 14 14 17.5 20 72.5 72.5 84 100 80.5 80.5 92 108 87 87 92 93 180.5 180.5 192 208 148 148 159.5 175.5 52 52 62 72 26 26 31 36 4.5 4.5 5.5 6.5 24.3 24.3 28.3 33.3 2.3 2.3 2.3 2.3 25 25 30 35 34 34 43 49 55 55 60.5 73 LVA LVH LVD Threaded Type Port size: 32A, 40A, 50A LVQ Electrical entry

Threaded type (6A to 50A) Flange type (32F to 50F) PA PAX PB 17-4-37 2 Series VND How to Order Body option Thread type Nil S Standard Stainless steel body Nil F N T Rc G NPT NPTF Threaded type only VND 15A Air operated 2 D S 0 Option Nil B None With bracket (VN-16) With indicator light L BL With bracket and indicator light Brackets (for valve size 1/2/3/4 only) will be assembled at the

N (Example) R73CN Operating time 1.2ms Operating temperature range 5 to 60C ((41 to 140F) Impact resistance 300m/s (11.2 in/s) (Reed), 1000m/s (39 in/s) (solid state) 2 Series CRB1 Specifications Single vane (S) Double vane (D) 90 , 180 , 270 +4 0 +4 0 +4 0 90 +4 0 100 +4 0 100 , 190 , 280 +4 0 +4 0 +4 0 Vane type Standard Rotation Optional Air (unlubricated) Fluid 1.5 (217 psi) Proof

-01ST 1/8" 8.4 20.4 27.5 4 9.3 12.7 5/32" 9.3 20.4 27.5 13.4 21 AS221F-01-06ST AS221F-N01-03ST 34.7 R1/8 12 14.2 7 1.5 31.6 13.5 6 11.6 21 13.4 34.7 AS221F-01-08ST AS221F-N01-05ST 16.5 NPT1/8 12.7 14.2 7 1.5 31.6 3/16" 13.2 24 31.1 18.5 25.3 32.4 8 15.2 23 23 AS221F-01-10ST AS221F-N01-07ST 15.3 17 1/4" 13.2 23.9 31 21 33.1 40.2 10 18.5 25 25 AS221F-02-04ST AS221F-N01-09ST 18.5 15.2 25.3 32.4

PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD 4 ON/OFF ON/OFF (kPaMPa

P Q Supply valve and release valve Supply valve Except nozzle diameter 05 type Note) Switch mounted style is also available. P. 13-4-17 to 13-4-19 13-4-4 4 Series ZM Vacuum Ejector: With Valve and Switch Construction: LZM1-KL-E Precautions Be sure to read before handling.

-01ST AS221F-01-04ST 1/8" 8.4 4 20.4 27.5 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 13.5 12 R 1/8 14.2 7 35.6 1.5 31.6 6 11.6 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT 1/8 12.7 14.2 7 35.6 1.5 31.6 18.5 25.3 32.4 8 15.2 AS221F-N01-07ST AS221F-01-10ST 1/4" 13.2 23.9 31 18.5 15 21 33.1 40.2 10 18.5 AS221F-N01-09ST AS221F-02-04ST 15 5/16" 15.2 25.3

80 100 115 217 (219) 246.5 (248.5) 282 (284) 301 (303) 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 50 60 79 90 77 1 8 1 2 3 x 3 4 3 x 1 1 4 95.5 111 119 VNH VNH 1 4 VND Note) ( ): CE-compliant product (-Q) VCC Model J K L M N O P Q R S T U VNH1 -10A A B VNH2 -15A A B VNH3 -20A A B VNH4 -25A A B M5 x 0.8 depth 5.5 M6 x 1 depth 6 M8 x 1.25 depth 6 M8 x 1.25 depth 6

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)