Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BASE MOUNT (AC) *LQA, VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, B/MOUNT, DIN (AC) *LQA
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BASE MOUNT (DC) *LQA
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (AC) *LQA
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BASE MOUNT, DIN (AC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BASE MOUNT (DC) *LQA
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 0.27 lb
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, N, "VALVE
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, N, "VALVE
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, N, "VALVE
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, N, "VALVE
, Ambient and fluid temperature: -10 to 50 C, VALVE, COMPACT, LATCHING, VALVE, VQ100 SOL VALVE 3-PORT, 1A, VQ100 OTHER SIZE RATING, .05511 lb
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
, Ambient and fluid temperature: -10 to 50 C, VALVE, COMPACT, CONNECTOR, VALVE, VQ100 SOL VALVE 3-PORT, 1A, VQ100 OTHER SIZE RATING, .05202 lb
, Ambient and fluid temperature: -10 to 50 C, VALVE, COMPACT, CONNECTOR (DC), VALVE, VQ100 SOL VALVE 3-PORT, BA, VQ100 BODY PT M5, .08706 lb
, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE PORT BLOCK, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, 21, SY7000 NO SIZE RATING, 0.13207 lb
The TIL series is also compatible with maximum fluid temperatures of up to 200¦C., TUBING, FLUOROPOLYMER, INCH, CONNECTORS, TIL/TL FLUOROPOLYMER TUBING, GX, TIL/TL 1/4" FLUORINE TUBING, 0.19596 lb