direction of the L and M connectors of a pilot valve is opposite to that of the single and double style.
A A A A 1 (Station n) (Station 1) L1 L2 4.5 (Pitch) P = 10.5 (Light/surge voltage suppressor) 15.5 15.5 (Station n) (Station 1) + + (Light/surge voltage suppressor) A A 20 48.5 [55.5] 15 5 B B + + 1.5 One-touch fitting (A, B port) Applicable tubing O.D.: 4, 5/32" (Pitch) P = 10.5 16 33.1 A A 20 15 B B 1 (Pitch) P = 10.5 16.5 5 M5 x 0.8 (A, B port) L plug connector (L) M plug connector (M)
Reference formulae [Dynamic moment at impact] Use the following formulas to calculate dynamic moment when taking stopper impact into consideration. m : Load mass (kg) F : Load (N) FE: Load at acceleration and deceleration (N) a : Set acceleration (m/s2) : Set speed (mm/s) M : Static moment (Nm) FE = m a Nominal size Maximum load weight (kg) 16 5 25 10 L1 : Distance to the loads center of
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
Lead wire length symbols: 0.5 m Nil (Example) F79W 3 m L (Example) F79WL 5 m Z (Example) F79WZ None N (Example) J79CN Refer to pages 1784 and 1785 for details of auto switches with a pre-wired connector.
Brown 12 Black 13 Red 7 Black 6 Orange 9 Black 8 3 Shield Vcc B-4 GND A-4 A B-5 A A-5 B B-6 B A-6 [Robotic cable, standard cable with lock and sensor for step motor (Servo/24 VDC)] LE-CP/Cable length: 1.5 m, 3 m, 5 m 1 3 5 For 3 Axes For 4 Axes JXC92 JXC73/83/93 Actuator side Controller side (8) (5.7) (14.2) Connector C (Terminal no.) Connector A B1 (Terminal no.)
Lead wire length symbols: 0.5 m Nil (Example) F79W 3 m L (Example) F79WL 5 m Z (Example) F79WZ None N (Example) J79CN Refer to pages 1784 and 1785 for details of auto switches with a pre-wired connector.
D1 M M A L1 D1 D2 L2 H Connection threads Male Branch: KPQU, KPGU (M5) Effective area mm D Model L TPH TPS A H (width across flats) (M5) 2-Applicable tubing Note1) Connection threads R Applicable tubing O.D. mm Weight g M P P M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 KPQU04-M5 KPQU04-01 KPQU04-02 KPQU06-M5 KPQU06-01 KPQU06-02 KPQU08-01 KPQU08-02 KPQU10-02 KPQU10-03 KPQU12-03 KPQU12-04
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 The 1 m lead wire is only applicable to the D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
I 0.33 0.14 (3.5)Dia (P,R portl < In Case of ll5) < In Case of 3 ) @ q , g @ A 10-32 Nnm. fM5) n ports L Type Plug Connector (L) M Type Plug Connector(M) Nom.
Hs D-A44 A A 49.5 Auto switch 376 Auto Switch Mounting CH2E/CH2F/CH2H Series Auto Switch Proper Mounting Positions CHQ D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F59F/F5BA Note2) D-A9/A9V Bore size (mm) D-G39/K39 D-A5/A6 D-B5/B64 D-A3/A44 D-F5NT D-A59W D-B59W CHK CHN A A A A A A A A A A A 32 25 21.5 26.5 17 15 19 15.5 18.5 CHM 40 26 22.5
f C B h + l A K N N H F F ZZ + l + 2 x strokes S + Stroke H + Stroke ZZ + 2 x strokes V W Cushion valve Port 4 x J G G 2 x P (Rc, NPT, G) M Width across flats KA Width across flats KA MM MM With rod boot (Both sides) E E D D e e C B l + Stroke l AL AL C B f f A K N N A K h + l h + l + Stroke S + Stroke ZZ + 2 x l + 2 x strokes (mm) Bore size (mm) Stroke range (mm) P S N MM M K KA W V J G
Manual override (Pitch) P = 10.5 9 (Pitch) P = 10.5 12.5 L2 3.5 L1 (Station n) (Station 1) (Station 1) (Station n) (Light/Surge voltage suppressor) (Light/Surge voltage suppressor) 43.5 [50.5] + + + + + + + 28.1 A A B B 15 15 12 12 B B A A 1 1 3 3 (Pitch) P = 10.5 13.5 (Pitch) P = 10.5 M3 x 0.5 (A, B port) M3 x 0.5 (A, B port) 14.5 L plug connector (L) M plug connector (M) M8 connector (WO
Description 12 16 20 25 32 40 50 63 80 100 19 to 20 25 to 29 Seal kit MGQ12-PS MGQ16-PS MGQ20-PS MGQ25-PS MGQ32-PS MGQ40-PS MGQ50-PS MGQ63-PS MGQ80-PS MGQ100-PS SYJ33--M A B VF34--M A B VZ54--M A B VZ34--M A B Solenoid valve with adapter assembly DPort thread type Nil N F Rc NPT G -X Since the seal kit does not include a grease pack, order it separately.
Dimensions are the same as standard type. 8-5-42 43 Air Slide Table Series MXQ External Dimensions of Adjuster Metal Stopper (CS/CT) Extension End (mm) Body mounting section Stroke adjustment range (mm) Body mounting section Table mounting section A Applicable size Model P D A B C F G M D E P *1) H J K Q 1) L MXQ-CS6(L) 5 15.5 MXQ6(L) M 6 19 7 7 M2.5 x 6 14.5 12.5 M2.5 x 8 8 2.5 7 8.3 M5
Applicable shaft types: K, T Equal dimensions are indicated by the same marker. 20L1 = L1 = L1 L1 = Q1 = M Q1 = M Q1 = M L1 = L1 Q1 = M L1= Q1 = M K axis L1 T axis Q1 Q1 (mm) Q1 Q1 L1 L1 Size Thread M 3 x 0.5 M 4 x 0.7 M 5 x 0.8 M 6 x 1 M 8 x1.25 M10 x 1.5 Rc 1/8 Q1 (mm) 20 30 10 15 40 J axis Z axis (mm) Size Thread M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 2.5 2.5 3.3 2.5 3.3 4.2 5
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,