Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, AIR HYDRO, A-SW, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, SE, 100MM CA1 DBL-ACT AUTO-SW, 18.24508 lb, ModelPort size (Rc)Rated flow rate (l/min) PaperMicromeshFH100-101 1/4120150
Output specifications 2CH X 2 outputs Number of outputs Pressure display range 101 to 10kPa (For vacuum), 10 to 100kPa (For low press.), 0.1 to 1MPa (For high press.)
(1 to 5 V) Caution Refer to pages 16-14-3 and 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. 16-4-2 3 LCD Readout Digital Pressure Switch Series ZSE3/ISE3 Specifications Positive pressure 1 MPa ISE3 Vacuum ZSE3 Positive pressure 100 kPa ISE3L Model 0 to 0.98 MPa 0 to 101
100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, 5 port solenoid valve, 4/5 PORT SOLENOID VALVE, VVD, 101
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, Finger valve, MECHANICAL VALVE, I70, 101 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, 5 PORT SOLENOID VALVE, 4/5 PORT SOLENOID VALVE, VVD, 101 lb
The SY is available in body ported or base mounted styles, and can be used individually or manifold mounted., VALVE, 2POS/DBL UL CONFORMING, 4/5 PORT SOLENOID VALVE, VVD, 101 lb
101 kPa500 kPaAir/Non-corrosive, non-flammable gas12 to 24 VDC ?10%, Ripple (P-P) 10% or less (With power supply polarity protection)17 mA or less at 24 VDC5 ms or less?1% F.S. or lessEnclosureOperating temperature rangeOperating humidity rangeVibration resistanceImpact resistance?3% F.S. or less1000 VAC for 1 min.
The settings of the master pressur, 2-Color Hi Precision Dig Pres Switch, PRESSURE SWITCH, ISE40, ISE40A, 841, 101 lb
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 140, 160 , Standard stroke (mm): 10 through 300 , Through hole mount, Auto switch capable, PISTON ASSEMBLY, COMPACT CYLINDER, 493, 101 lb
10Max. 14MPaFH540-10FH541-101 1/432 (1 1/4B)120
ModelPort size Note)Rated flow rate (l/min) INLETOUTLETFH990-101 1/2B1 1/4B150
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread, Connector Type: S (M12 Connector Type)
System: P (Vacuum Pump System, Single Unit), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: None, Pump System PE Port Female Thread: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)