Bore size Applicable series 02 03 04 06 10 12 14 20 Note 1) AS800 is available as special.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size (IN, OUT port) Single Port size Rc size VR VPA3145 VPA3165 VPA3185 Symbol Body size 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 1 4 6 1 2 VH 04 06 10 12 14 20 8 1 2 1 Valve option VHS Nil For general purpose (32A) 1 4 1 (40A) 1 2 1 Body ported
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
If possible, we recommend using a combination of 2 types of fittings. Refer to the examples below.
① KQ2E12-00□ (Bulkhead union) + KQ2R08-12A (Plug-in reducer)
② KQ2E12-03□ (Bulkhead connector) + KQ2H08-03□S (Male connector)
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
The base color of the new AC series is urban white, maintaining a clean, modern look.Air filter, regulator and lubricator unit , Clean looking, urban white, modular design , Energy saving with high flow rate , Transparent bowl guard, New spacer for modular connection is interchangeable with existing product, Improved installation , Rc, G or NPT threads AC MASS PRO. F/R COMBO MODULAR.
The base color of the new AC series is urban white, maintaining a clean, modern look.Air filter and regulator unit , Clean looking, urban white, modular design , Element and bowl are in one-piece for easy replacement (AF), Energy saving requlator (AR), Transparent bowl guard provides 360 degree visibility MODULAR F.R.L.. F/R COMBO MODULAR. 0.497 lb. 11.
The base color of the new AC series is urban white, maintaining a clean, modern look.Air filter and regulator unit , Clean looking, urban white, modular design , Element and bowl are in one-piece for easy replacement (AF), Energy saving requlator (AR), Transparent bowl guard provides 360 degree visibility MODULAR F.R.L.. F/R COMBO MODULAR. 0.561 lb. 11.
The AFM's standard filtration is 0.3µm with a 99.9% filtered particle size. Body size 30 and 40 now have a transparent bowl guard that offers 360° visibility, while completely protecting the bowl from the environment. The modular design allows connection with other SMC air preparation equipment. Use in combination with the AF series to meet your clean room filtration requirements.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, EA, AIRLINE EQUIPMENT, Auth/Grp: 2/52, 180, AC MASS PRO
Body size 30 and 40 now have a transparent bowl guard that offers 360 visibility, while completely protecting the bowl from the environment. Accessories include a bracket, and float type auto drain., MICRO MIST SEPARATOR, AIRLINE EQUIPMENT, AFD MASS PRO, EA, AFD MASS PRO 3/8 MODULAR (PT), 3.83604 lb
Series IR Precision Regulators are designed to be compact and light weight. The maximum set pressure has been expanded from the conventional 0.7MPa to 0.8MPa. Relief flow has been increased by nearly 5 times (compared to SMC IR201, IR401). The optio, ZERO BLEED PRECISION REGULATOR, PERCISION REGULATOR, O32, 0.47 lb
The base color of the new AC series is urban white, maintaining a clean, modern look.Air filter and regulator unit , Clean looking, urban white, modular design , Element and bowl are in one-piece for easy replacement (AF), Energy saving requlator (AR), Transparent bowl guard provides 360 degree visibility, F/R COMBO MODULAR, MODULAR F.R.L., 11, 1.25100 lb
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/4, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment