NON-MOLDED MOLDED 60 HZ. 50 HZ. VOLTAGES COIL NO.
/50 Hz, 3.0/60 Hz CV Note) At the rated voltage.
106 (170) L 86 A (Table traveling distance)2 86 62.4 88 [(90)]4 (90) [88]4 13 Stroke 90 Origin3 2 [(4)]4 (4) [2]4) [Origin]4 60 61 (8.5) 53.8 68 (68) 60 31 M4 x 0.7 thread depth 8 (F.G. terminal) 8 B D x 150 (= E) 8 15 60 6H9 ( ) depth 6 +0.030 0 150 Motor mounting position: Left side parallel LEFS40L 153 7 76 60 64 n x 6.6 Motor mounting position: Right side parallel LEFS40R 153 60 64 *
Hz 50 20 11 60 17 7 50 42 18 60 37 12 50 55 22 60 47 18 60 40 60 AC DC AC DC 60 60 40 60 60 Apparent power VA Model Power Max. Inrush Holding Note 1) Differ from the operating condition of pressure. Note 2) Value on option "V", "R", "Y" (Nonleak, Vacuum). (1) 10 (1) 5 AC 20 10 Min.
/60 Hz) 3-phase 460 to 480 VAC (60 Hz) When multiple options are combined, indicate the symbols in alphabetical order.
Mounting bolt 6.5 8.5 Note) When mounting a cylinder with through-hole, be sure to use the attached plain washer. 6.5 Material: Chromium molybdenum steel Surface treatment: Zinc chromated Mounting Bolt for CDQSYB with Auto Switch Cylinder model C Cylinder model C D 60 65 70 75 80 85 45 50 55 60 65 70 75 80 85 90 D 35 40 45 50 55 60 35 40 45 50 55 60 40 45 50 55 Mounting bolt part no.
AL30 to 60 AL30 to 60 AL10 to 60 AL10 to 60 AL10 to 60 AL30 to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 10 20 30 40 50 60 M5 1/8 3/8 1/2 3/4 1 Thread type AL20 Port size Metric thread (M5) Rc NPT G Symbol Nil Nil M5 01 02 03 04 06 10 M5 x 0.8 1/8 1/4 3/8 1/2 3/4 1 Note) N F Accessory When more than one specification is required, order in alphanumeric order.
Bore size (mm) B TA TL TU TC TX TE TO TR TT TS TH TF Z** TDH10 MB-S03 32 46 62 45 8.5 62 50 74 12 7 13 10 35 47 89 12+0.070 0 MB-S04 40 52 80 60 10 80 63 97 17 9 17 12 45 60 93 16+0.070 0 50 65 80 60 10 92 75 109 17 9 17 12 45 60 105 16+0.070 0 MB-S06 63 75 100 70 15 110 90 130 20 11 22 14 60 80 105 20+0.084 0 80 95 100 70 15 130 110 150 20 11 22 14 60 80 129 20+0.084 0 MB-S10 100 114 120
: 200 VAC (50 Hz), 200/220 VAC (60 Hz) Three-phase: 200 VAC (50/60 Hz) Motor Type Auto Drain Model Operating cycle IDF370D 4 times per minute for 8 seconds every one minute Refrigerant R407C (HFC) IDF E Power consumption [kW] 50/60 Hz *6 Three-phase 200 V 4.9 6.3 11.6 5.9 7.6 11.6 Electric specifications Power supply 200 VAC 50/60 Hz Power consumption 4 W Operating current [A] 50/60 Hz *6
, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch Refer to the table below for selecting applicable auto switches.
60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.
VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option 3-5-94 95 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR6000 Cylinder Speed Chart Use as a guide for selection.
MHR Max. operating pressure (MPa) Min. bending radius (mm) MHK Operating temperature (C) Material 20 to 60 Nylon 12 20 to 60 Nylon 12 20 to 60 Polyurethane 20 to 60 Polyurethane MHS Refer to Best Pneumatics Vol. 15 regarding One-touch fittings and tubing.
MHZ Applicable Tubing Max. 5 MHF B 5 A E2 Nylon tubing T0425 TS0425 TU0425 TCU0425B-1 coil tubing Soft nylon tubing Polyurethane Polyurethane Description/ Model Specifications tubing MHL Auto switch mounting groove (Both sides) Outside diameter (mm) 4 1.0 13 20 to 60 Nylon 12 4 0.8 12 20 to 60 Nylon 12 4 0.5 10 20 to 60 4 0.5 20 to 60 Refer to the dimension table.
The load factor for each direction can be obtained as follows. x = 0/400 = 0 y = 50/250 = 0.2 z = 200/1500 = 0.13 5. x + y + z = 0.33 1 2000 1000 2000 800 1500 1500 Lz 600 L1 [mm] L3 [mm] L2 [mm] 1000 1000 400 Ly 500 500 200 Lx 0 0 0 0 10 20 30 40 50 60 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] 44 Model Selection LEF Series Step Motor (Servo/24
Frequency (Hz) 45 40 55 50 65 60 Inrush Frequency (Hz) 50 45 55 50 65 60 50 60 50 60 50 60 50 60 50 60 50 60 9 7 19 16 30 25 11 8 20 18 32 27 VX21 VX21 VX22 VX22 VX23 VX23 Note) The values are for an ambient temperature of 20C and at the rated voltage.
115 74 48 17 135 20 46 M45 x 1.5 260 50 71 67 140 86 60 20 160 25 56 M56 x 2.0 285 60 71 67 140 86 60 20 160 25 56 M56 x 2.0 296.5 60 80 76 140 96 60 20 175 30 65 M64 x 2.0 325 70 ZZ + Stroke 80 76 140 96 60 20 175 30 65 M64 x 2.0 325 70 1728 Made to Order Common Specifications: -XB6: Heat Resistant Cylinder (10 to 150C) Symbol -XB6 Heat Resistant Cylinder (10 to 150C) 2 Air cylinder which
D 4 4 6 6 Model LXFHAB25--X LXFHAB50--X LXFHAB75--X LXFHAB-100--X B 1 1 2 2 E 60 90 90 90 F 30 60 60 60 G 60 90 90 90 Note) The overall length of an actuator is Stroke + 105.5 + Motor dimension.
60 50 0 to 120 30 to 200 0 to 60 0 to 250 20 to 150 X X X X The above table covers only general characteristics of subject rubber materials.