2 w e !3 !4 r t y u i !5 !6 No.
Clean series 10 AF 03 A 30 F J B 21 AF 03 A 30 F J B Copper, fluorine and silicone-free + Low particle generation q w e r t Air filter Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
Unit No. : Refer to the "Unit address order" of (A) Master unit setting (page 22) or (A) Slave unit setting (page 38) for IO mapping position. -52No.EX-OMV0017 (e).
[F 2] OUT2 e. ([ tPL]) [ tPH] or [ tnH] ([ tPH]) 4.
P PNP C E U 1 C E U 5 AC80120V AC100240V DC24V DC24V NPN RS-232C P PNP RS-232C+BCD NPN P PNP C E 1 R *1) (CE1-ROOC) 05 5m 10 10m 15 15m 20 20m *1)() C ()(CE2)(CE2**-*Z ) CE1-ROOC CE1-RO5 CE1-R10 CE1-R15 CE1-R20 CE1-R*C 11 3 100 200 200 NO 100 80 YES 100 100 80 kgf kgf 63 NO 63 50 50 40 40 YES 100 100 300 300 200 400 500 200 400 500 NO mm/s mm/s OK YES NO NO YES
Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.
3 w e q !1 r y o e t !2 For 4 Built-in magnet Without magnet Single acting u i r y o e w i e u !0 Built-in magnet Without magnet Rod end male thread Parts list Replacement parts: Seal kits (double acting) Contents Note No. Description Material Kit no. Bore size 1 Hard anodized Aluminum alloy 4 CUJB4-PS Cylinder tube 2 Above numbers 11, 12, 13 and an exclusive grease pack.
Inlet air temperature 35C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.5MPa Air flow 1200 l/min (ANR) Inlet air temperature 55C Outlet air pressure dew point 10C Ambient temperature 35C Inlet air pressure 0.7MPa Air flow 350 l/min (ANR) Condition Condition A = 0.75 based on conditions q, w and e 1 B = 0.95 based on conditions q, w and e 1 C = 1.00 based on
Symbol x 50 001 005 010 020 050 075 100 002 004 006 013 q q w w 0.01 0.01 e r e 0.005 0.005 r 0.002 5 10 50 100 0.002 10 50 100 Flow rate l/min (ANR) Flow rate l/min (ANR) Note) The recommended flow rate is the rate for an initial pressure drop of 0.01 to 0.02 MPa. 2 Series FQ1 How to Order Filters Element and Seal Part Numbers 1.
C D E F G J K VHK R-01S-01S 13 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 13 17 19 22 VHK R-02S-02S 17 VHK R-03S-03S 19 VHK R-04S-04S 22 5-8-5
Symbol x 50 001 005 010 020 050 075 100 002 004 006 013 q q w w 0.01 0.01 e r e 0.005 0.005 r 0.002 5 10 50 100 0.002 10 50 100 Flow rate l/min (ANR) Flow rate l/min (ANR) Note) The recommended flow rate is the rate for an initial pressure drop of 0.01 to 0.02 MPa. 2 Series FQ1 How to Order Filters Element and Seal Part Numbers 1.
Condition Condition Inlet air temperature 35 C Outlet air pressure dew point 10 C Ambient temperature 35 C Inlet air pressure 0.5MPa Air flow 1200 l/min (ANR) Inlet air temperature 55 C Outlet air pressure dew point 10 C Ambient temperature 35 C Inlet air pressure 0.7MPa Air flow 350 l/min (ANR) A = 0.75 based on conditions q, w and e 1 B = 0.95 based on conditions q, w and e 1 C = 1.00 based
e E , q 1.5 8 1 2 1 6 2 0 Cylinder speed (in/sec.) Sl6ct a propr unit sccording to exhaust flo/, in lh6 following ordr: (l) Oete|mine air con6umplion ot actuaicrs uaed in tl|e ckc\rii.
The “E” and “N” valve part number prefixes are region codes: “E” is for Europe and “N” is for North America.
They are no longer used, and so the standard part number is the same excluding the “E” or “N.”
Note that the thread type symbol may have been omitted from the part number depending on the region.
When replacing the product, be sure to confirm the thread type beforehand.
Port size A B C D E(Option)Model Port size A B C D E(Option)Model Port size A B C D E(Option)Model Port size A B C D EFG H JK--INA-11-4053/48518020
t w t Port 3(R) e r Port 3 (R) Port 2 (A) Port 1 (P) Port 23(P2) (Pilot air port) y i Port 2(A) u r y Port 1(P) t q VEX3320 (Air operated) VEX3420 (Air operated) w e q r y y t w r e u t t 12(P1), 23(P2) Port Port 3(R) y y (Pilot air port) r i Port 2(A) u r Port 1(P) t q Port 1(P) Port 2(A) Port 3(R) Component Parts No.
When the volume of oil reaches a certain level, float e ascends, valve t descends via lever r, nozzle w closes, and the feeding of oil stops, thus completing the oil feeding process. When the oil inside the case is consumed, float e descends, valve t ascends via lever r, allowing oil to be fed from nozzle w.
If it does not locked easily, turn the handle s l i g h t l y c l o c k w i s e o r counterclockwise; then, push it until the orange colored line is no longer visible.
AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series
Option Symbol and Composition Option Symbol and Composition Main body, shading coil material Holder material (in core ass'y) Option symbol Seal material Coil insulation type Main body, shading coil material Standard A B D E F G H J L N P T X Option symbol Seal material Coil insulation type NBR FKM Standard A B D E F G H J L N P T X NBR FKM B Polyacetal B FKM EPDM Brass or BC6, Copper FKM