Note) Flange type F is not available. Air cushion Number of auto switches Nil None C With air cushion Shaft type Nil 2 pcs. S 1 pc.
A B C D E F A B C D E F G H Pressure port Pressure port Right Left Left Right Left Right Right Left Left Right Right Left Left Right Operating direction Operating direction There are 9 possible reciprocating piping methods. There are 16 possible reciprocating piping methods.
Table displacement due to yaw moment load Displacement at A when load is applied at F . Table displacement due to roll moment load Displacement at A when load is applied at F .
F-91S F-87S FGFC5-60 FGFL3-40 Carbon steel F-88S FGFR5-60 FGFC5-60 150(6B) F-92S F-88S 280 240 166.6 23 22 FGFS5-60 FGFR5-60 Stainless steel F-89S AL-80S AI-18S FGFL5-60 FGFS5-60 F-93S F-89S FGFL5-60 Note) 2 pieces are required per filter unit. JIS10KFF is used for this flange. Foundation bolt L1 (mm) Nominal thread size d M16 L1 R Applicable model d1 S L Part No. (Approx.) (Approx.)
Operating pressure: 0.4 MPa Model Selection Illustration When gripping a workpiece as in the figure to the left and with the following definitions, F: Gripping force (N) : Coefficient of friction between attachments and workpiece m: Workpiece mass (kg) g: Gravitational acceleration (= 9.8 m/s2) mg: Workpiece weight (N) F F the conditions under which the workpiece will not drop are mg F F
Eliminate the unnecessary parts. 1.10-13 Series CS1 Front Flange/CS1F Lube (CS1F), Non-lube (CS1FN), AIr-hydro (CS1FH) Long stroke With auto switch/CDS1F (mm) Stroke range (mm) W/o rod boot With rod boot Style Bore (mm) J FT FX FD S AL B E F FA KA M MM H A D EA FY FZ G K N P B C h ZZ e f l ZZ1 125 140 160 180 200 250 300 115 1/2 M30 X 1.5 145 75 40 145 190 100 230 M14 X 1.5 110 238 133 261
Operating pressure: 0.4 MPa Model Selection Illustration When gripping a workpiece as in the figure to the left and with the following definitions, F: Gripping force (N) : Coefficient of friction between attachments and workpiece m: Workpiece mass (kg) g: Gravitational acceleration (= 9.8 m/s2) mg: Workpiece weight (N) F F the conditions under which the workpiece will not drop are mg F F
mg F F Gripping force at least 10 to 20 times the work piece weight The "10 to 20 times or more of the work piece weight" recommended by SMC is calculated with the safety margin of a = 4, which allows for impacts that occur during normal transportation, etc. 2F mg Number of fingers and therefore, mg F 2 x With "a" as the safety margin, F is determined as follows: mg F = x a 2 x When
F = one finger thrust.
NA S + Stroke F H WH B ZZ + Stroke (mm) A B C D E F GA GB H H1 H2 I Bore size (mm) Stroke range (mm) Effective thread length 26 8 5 44 47.5 53.5 16 14.5 10 18 40.5 32 15.5 200 to 700 20 31 8 6 48 49.5 56.5 16 18 12 22 45.5 36 19.5 200 to 700 25 38 9 6 51 51.5 55 19 18 12 22 51.5 44 19.5 200 to 1000 32 47 11 8 54.5 51.5 56 21 20.5 16 24 61.5 53 21 200 to 1000 40 N NE NA NB NF ND NN P S WH
Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.
Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.
Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.
ON: Green OFF: Red [F 2] Setting of OUT2 Same setting as [F 1] OUT1. At the output mode, Error detection mode can be selected. Display color is linked to the setting of OUT1, and can not be selected.
P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 e OR-1400-178P P: PTFE F: FKM OR-2670-178P r P: PTFE F: FKM Wave washer For VCS30, 40 When the loosened clip is pulled out in direction e using pinchers, etc., the coil can be removed and replaced in direction r.
P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 OR-1400-178P P: PTFE F: FKM OR-2670-178P P: PTFE F: FKM For VCS30, 40 OR-1717-178P When the loosened clip is pulled out in direction using pinchers, etc., the coil can be removed and replaced in direction .
Thread Rc(PT) T NPTF F G(PF) N NPT Example of ordering a manifold base: The valve and blank plate for manifold arrangement should be specified in order from the left side of the manifold base (With the A port on your side). (Example) VVEX2-2-7-02N VEX3222-1LN 6 pcs. VEX1-17 1 pc. VVEX4-2-6-A VEX3420 5 pcs. VEX4-5 1 pc.
105 CKZ80-42 3680N-R D E F 30 to 105 For mounting bolt, a hexagon socket head cap screw and a spring washer No. 2 are recommended.
Water Hammer Characteristics VNC1 (N.C. 0.49 MPa) Conditions: Piping 30 m Steel tube, total pressure 0.49 MPa VNC4 (N.C. 0.97 MPa) Conditions: Piping 30 m Steel tube, total pressure 0.97 MPa 2.5 15A Peak pressure at valve closed (MPa) Peak pressure at valve closed (MPa) 8A 25A 2 1 20A 32 A F 15A 20A 40 A F 32 A F 1.6 0.8 25A 40 A F 50 A F 65F 50 A F 1.2 0.6 80F 65F 80F 0.8 0.4 0.4 0.2 0 1
Calculation example Calculation for allowable external force (with moment load) When static load f = 10 N, which produces pitch moment to the point L = 30 mm from MRHQ16D guide, is applied. Operable condition requires that F be bigger than f.