pc pkg = 1), VQ1000/VQ20/VQ30 VALVE*** $5.09 + Add to Quote Add To Cart Add to Cart SMC VVQ1000-80A-2 gasket (12 pc pkg = 1), VQ1000/VQ20/VQ30 VALVE*** $5.09 +
Tightening torque: AW10 AW20(K) AW30(K) AW40(K) AW60(K) 21 3 to 4 Nm 12 7 to 9 Nm 14 12 to 14 Nm 7. Pressure Gauge Adapter, Plug Assembly Process Procedure Tools Check item Applicable model Actuators Modular F.R.L. Pressure Control Equipment Disassembly Hexagon wrench key Nominal: AW20(K) AW30(K) AW40(K) AW60(K) 1) Remove the plug.
40 6.6 6 42 93 32 59.5 37.5 10 12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90 13.5 16 91.5 202 100 116 66 19 31 280 308 62 100 15.5 22 111.5 240 Caution Do not use this cylinder as a stopper.
6 1/4" 12 40.7 AQ340F-07-00 AQ340F-07-07 16.8 20.3 13.7 16.8 7.1 52.2 33.1 20.0 13 11.8 1/4" 13.2 11 1/4" 13.2 7.1 22.2 15-12-4
6 Body size If more than one option is required, write option part numbers in the order of K, N. 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size (1) 4 6 8 10 12 04 06 08 10 12 Electroless nickel plated (3) Brass PBT PBT/Stainless steel NBR NBR NBR NBR NBR NBR NBR/Stainless steel Electroless nickel plated Elbow type Control method Meter-out Meter-in 0 With One-touch fitting
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Burst pressure 25 20C to 60C Nylon 12 Min. bending radius (mm)(1) Operating temperature Material Note 1) The value at temp. of 20C and with O.D. variable rate 10% max.
Bore size 12 16 20 25 L F G D 12mm 16mm 20mm 25mm Standard (rod end female threads) With rubber bumper Rod end male threads Combination of the above specifications is possible.
CXS25-35-XB19 35 131 107 16 12 40 CXS25-40-XB19 40 136 112 CXS25-45-XB19 45 141 117 CXS25-50-XB19 50 146 122 CXS25-60-XB19 60 156 132 CXS25-70-XB19 70 166 142 CXS25-75-XB19 75 171 147 60 CXS25-80-XB19 80 176 152 CXS25-90-XB19 90 186 162 CXS25-100-XB19 100 196 172 CXS32--XB19 36 1 38 S 18 12 ZZ 30 Z SS 2-6 x 32l AW (spring pin) 26 9 2-6.9 through 2-11 counter bore depth 6.3 98 96 1 6.3 76
i 1 6 30 46 1 0 21 50 168 0 70 I 12 90 50 1 0 58 238 52 1 . 2 66 31 % 44.5 1 3 23 60 182 0 86 105 59 130 58 52 1 1 . 2 66 37 % 55 1 5 70 208 0 '102 1 8 130 160 71 297 65 't2.5 80 1 4 40 12 1 5 25 80 226 0 1 1 6 13.5 t 8 150 92 1 8 0 72 3 1 6 65 14.0 8 1 ra Single Glevis Type/CLAC with Bod Boot M14x r.5 M 1 8 X 1 . 5 M18X1.5 M22X1.5 M26X1.5 Dill|o||$io[$ $enies CIA Double Glevis TyPe/CLAD
N FA FB L1 L3 L4 L5 L6 P Q1 Q2 MA MB KM11-04-08-6 6 65 40 61.5 47 73 55 86 22 30 32 44 44 62 8 4 10.6 10 18 29.5 19.5 27 12 16 18.5 6 KM11-04-08-10 10 86 KM11-06-10-6 6 76 KM11-06-10-10 10 102 10 6 13 10 19.5 31.5 21.5 31 13.5 17 21 7.5 KM11-08-12-6 6 85 KM11-08-12-10 10 116 12 8 11.5 22.5 35.5 24 34.5 14.7 18.5 22 9 15.5 KM12/Dimensions Inch H (Hex.) Thead NPT T Applicable tube O.D.
REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable range Usable range 5 5 5 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 12
(OUT1) Black Main switch circuit Load Connector DC polarity indication 30V, 80mA (OUT2) + White _ 12 to 24VDC Load 30V, 80mA Lever Hysteresis setting trimmer Blue DC () Pressure setting trimmer Pin Slot ZSE1-18,-19 HYS Indicator light SET Brown DC (+) Housing (OUT1) Main switch circuit Black Load 30V,80mA + Analog output 12 to 24VDC Load White Blue DC () 2.
DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -19No.PS-OMU0002CN-D Z/ISE20A(F)-S/-R () DC(+) NPN 2 Max.28 V80 mA 1 V R15 V OUT1 1 k OUT2 S420 mA DC(-) 12 V 300 24 V 600 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -20No.PS-OMU0002CN-D -V/-T () DC(+) PNP 2 Max.80 mA 1 V T15 V OUT1 1 k OUT2 V420 mA DC(
V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -X () -S/-R () NPN 2 Max.28 V80 mA 1 V -21No.PS-OMU0005CN-C -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -Y () -V/-T () PNP 2 Max.28 V80 mA 1 V -22No.PS-OMU0005CN-C [] 3 0.2 [] / OUT2 OUT2 OUT1 OUT1 [F10]30 () 13 35 1 (62 ) () () (27 ) (29 ) (3 ) (25 ) 3 () 3
No.PS-OMM0006CN-E // ZSE40A(F) ISE40A 2 9 12 13 16 16 18 20 23 23 25 25 25 F0 27 F1 OUT1 28 F2 OUT2 31 F3 33 F4 34 F5 / 36 F6 38 F11 39 F80 40 F81 41 42 F90 42 F97 44 F98 46 F99 48 49 52 52 53 60 60 63 -1No.PS-OMM0006CN-E (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules
~14 Nm 17mm 17 mm () TU0425 ( 4 2.5) -16No.PS-OMM0002CN-F Z/ISE80---N NPN Max.28 V80 mA 1 V -P PNP Max.80 mA 1 V -S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -17No.PS-OMM0002CN-F -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -A NPN2 Max.28 V80 mA 1 V -B PNP2
DIN rail ISA-5Part number L Number of stations ISA-5-1 73.0 1 ISA-5-2 135.5 2 ISA-5-3 173.0 3 ISA-5-4 210.5 4 ISA-5-5 248.0 5 ISA-5-6 285.5 6 Seal for extra station ISA-15 Threaded plug with seal ISA-12Piping type Part number Rc1/8 ISA-12-A : This is applicable in both G1/8 ISA-12-C piping specification C and F. -11No.PS-OMT0002-E 2 About this product Centralized lead wire ISA-21Bracket
Rc1/8 4 1 6 2 1 3 G1/8 G1/8 3 7 NPN2 PNP2 A B 4 L 7 5 SI N 1 2 3 1 2 3 4 5 6 S 6 7 8 4 5 6 6 7 8 T 1F 2GH 3ISO1179-1 4 5kPa 61 7 88 (10 ) 9DIN 101 1 2 2 -8No.PS-OMT0001CN-E 2 B 2 F 0.010.03mm 0.020.15mm 0.050.30mm G H DC24V AC100V AC110V 10 1 10 2 Rc1/8 4 1 C 2 6 10 N 3 10 0.4MPaMPa 0 G1/8 F G1/8 3 1 11 0.4MPaMPa 0.2MPaMPa 0.2MPaMPa 2 3 C Rc1/4 F 12
(P1),23(P2) (2) a 12(P1) 1(P)2(A)3 3(R) 3(R) b 23(P2) 2(A) 2(A)3(R)1 1(P) 1(P) 12(P1) 1 2 3 23(P2) 4 5 6 7 8 POM 9 -12No.VEX-OMY0001 () () 3(R) 2(A) 1(P) 1(P) 2(A) 3(R) () a b P1P2 2(A) 1(P) -13No.VEX-OMY0001 (7) (1) (2) (3) (4) (5) (6) (12) (7) (8) () (9) (5) (6) (14) (10) (P2) (5) (4) (11) (4) (13) DCAC (7) 14 No.VEX-OMY0001 o. (1) (2) (3