SMC Corporation of America
Elite Part Number Search
Search Results "CRBW40-90-AM"

retraction When the cylinder is extended KA: T-slot for hexagon bolt 4 x M K KB KC 6-K (6 positions) 10 10 M12 x 1.75 M10 x 1.5 M8 x 1.25 M Bore size Standard stroke (mm) GB D A 170 140 10 10 38 38 36.5 E B F KC 11 11 8.7 120 X T V 1/4 1/4 1/8 40 P 46 46 38 PP 70 50 M12 x 1.75 M10 x 1.5 M8 x 1.25 N H GA C M6 M6 M5 18.5 KA KB 100 63 30, 50, 75, 100 40 78 73 58 66.5 61.5 48.5 4 4 3.5 8 100 90

10 4.5 J depth 1.5 3 6 +0.030 0 10 9.5 4 Section AA B D Mounting base side +0.030 0 Q QL depth 1.5 3 11-/22-MXP10-20 Without magnet and switch rail Max. 2.5 2 x M2 x 0.4 depth 3 8 2.5 4.7 15 15 L 6 x M3 x 0.5 depth 4 2 x M3 x 0.5 depth 3.5 (mm) G H J K L M N Q QL S V W Z Model 11-/22-MXP10-10 8 32 52.4 20 20 21 6.5 32 14 10 44 40 60 11-/22-MXP10-20 20 50 82.4 36 36 39 7.5 50 20 20 74 65 90

Change of electrical entry (Orientation) After separating terminal block and housing, the cable entry direction can be changed by attaching the housing in the desired direction (4 directions in 90 increments). In the case of w/ indicator light, avoid damaging the light with lead wire. Precautions Plug a connector in or out vertically, never at an angle.

VCC TQ 621 A VNC Series Threaded Type/Port size: 10A, 15A, 20A, 25A K L Pg9 N P Applicable cable O.D. 6 to 8 F (Air operated) J (External pilot solenoid) Pilot port 12(P1) 2 x (Back side 10(P2)) 4 x M 8 1 Light/surge voltage suppressor (For DZ) Manual override (Non-locking push type) P1 D S Q E Bracket 15 H A R B C Main port 1(A) [Back side 2(B)] Port size: refer to table below A 63 63 80 90

R Pilot port 12(P1) Indicator (Option) 1 8 2 x (Back side 10(P2)) VNA P1 4 x P S VNB F U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 TQ 80 90

VNA VNB Flow indicator for 2 port valve SGC Dimensions SGH (mm) Main port 1, 2, 3 2 Port 2 x 2 x Pilot port 12(P1), 10(P2) A B Note) C D E F G H I Model 3 Port 3 x 3 x VNC 3 8 1 2 2 x 3 4 2 x 1 3 8 1 8 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 60 80 100 115 217 (219) 246.5 (248.5) 282 (284) 301 (303) 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 50 60 79 90

(Normally open) Series 3 5 7 VPA300 VPA500 VPA700 Thread type Body option Nil F N T RC G NPT NPTF Nil V Standard For vacuum Manifold Specifications Piping specifications Applicable stations Note) Manifold base Weight: W [g] Stations: n Applicable valve Series Base model 1P (SUP) port type 3R (EXH) port type Port size VV3PA3-41 Common VPA300 2 to 20 stations W = 110n + 90 1/4 VPA344 VV3PA3

Series VXA31/32 Dimensions P port Bracket Pilot port J (Spanner flat) Port size P Port size Rc With bracket K 6 7.5 Symbol Model A B C D E F G H J L 29 32 M 14.5 17 1 8 1 4 VXA31 VXA32 19 25 20 20 18 21 20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 , , 1 4 3 8 17-3-104 The VX series will be revised shortly.

defined by the product specifications. 82 WRF100 Dimensions WRF-S/S-type clamp arms (Without cover) WRF100-S200/S240 4 x M8 x 1.25 depth 12 108 60 2 x M12 x 1.75 through 25 25 80 0.015 0 2 x 8H7 ( ) 60 0.05 depth 12 (2 x 4 x M5 x 0.8 through) ( ) C B For limit switch mounting A 60 60 36 0.5 Switch mounting bracket Note 2) 0.2 25 25 13 Fulcrum 12 12 20 10 10 2 x M10 x 1.5 through 45 F 30 90

Hexagon width across flats 8 M5 x 0.8 Hexagon width across flats 12 M8 x 1.25 Hexagon width across flats 10 H F Hexagon width across flats 2 Y 2 Y A B 2.5 A B Stroke: 10 mm Dimensions: 10 mm Stroke (mm) Model A B C D F Y H I J K K Q: 4 Q: 6 ZPT10F10-0-A10 12 12.5 27 10 10 38.5 74.5 88.5 89.5 1.5 ZPT13F10-0-A10 39 23 Hexagon width across flats 13 15 13 1/8 (Rc, NPT, NPTF) 10.5 13 27.5 75 89 90

The spacing (l) of the side support must be no more than the values shown in the graph at right. 100 m 90 l 80 70 (650) Caution 60 Load weight m m qIf the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Make sure to level the cylinder tube when mounting the cylinder.

As a guide, turn about 90 past the point at which tightening can first be felt. MVGQ CC Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. For detailed specifications, refer to page 10-20-1.

Tightening torque for DIN rail clamp screws on end block 90 1.50.15Nm OPEN 14-4-49 32 Pressure Switches/Series ARM10/11 Specific Product Precautions Be sure to read before handling. Wiring Design & Selection Warning Warning 1. Operate the switch only within the specified voltage. 1.

JIS Class 2 Thread tolerance CNS Basic style, Axial foot style, Rod side flange style, Head side flange style, Rod side trunnion style, Head side trunnion style, Clevis style (used for 90 change of port position) Symbol Specifications Mounting -XA Change of rod end shape CLS When the piston is locked, the load weight is limited by the mounting orientation and the operating pressure.

Shock absorber model Applicable bore (mm) CLS ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 RB1412 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 CLQ RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 MLGP Side Support RLQ Side support A MLU ML1C D-X 20Data Side support B A B C D E F G H J Part no.

RLQB40-30 RLQB40-40 RLQB40-50 RLQB40-75 RLQB40-100 RLQB50-30 RLQB50-40 RLQB50-50 RLQB50-75 RLQB50-100 RLQB63-30 RLQB63-40 RLQB63-50 RLQB63-75 RLQB63-100 M5 x 90l M5 x 95l M5 x 100l M5 x 110l M5 x 120l M5 x 145l M5 x 170l M5 x 100l M5 x 105l M5 x 110l M5 x 120l M5 x 130l M5 x 155l M5 x 180l M6 x 120l M6 x 130l M6 x 140l M6 x 165l M6 x 190l M8 x 125l M8 x 135l M8 x 145l M8 x 170l M8 x 195l 90

HT HS HB HA HB HA HG HT HI WB 4-J Depth JK Plug [P (port f)] WB WA TA TA WA R TB Plug TB R W [P (port d)] Inner cover Note 3) holding screw (mm) K 21 20 JK 10 12 J M6 x 1 M10 x 1.5 HT 19.5 39 HS 27 49.5 HP 44 73.5 HL 38.6 64.9 HI 23 39 HG 8.5 19 HB 8.5 19 HA 19.5 39 H 45 75 G 6.5 8.5 F 12.5 25 EK 4 6 ED 9.5 13 E 4H9 6H9 B 9.5 14 A 8 12 C 5.4 8.6 Model +0.030 0 +0.030 0 CYP15 CYP32 L 67 90

TB W Counterbore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60 100

The spacing (l) of the side support must be no more than the values shown in the graph at right. 100 m 90 l 80 70 (650) Caution 60 Load weight m m If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Make sure to level the cylinder tube when mounting the cylinder.