OMM0003 VP31 5 3 / / () C-R C-R ( ) DC 5% AC 15% (ON)(OFF) 0.1 0oC 0.2Mpa (INOUT ) 4 VP3145-OMM0003 VP31 5 3 / ( ) 9 ) 1 ()ISO VG32 2 ()ISO VG32 5m Nm Rc 3/8 2224 Rc 1/2 2830 Rc 3/4 2830 Rc 1 3638 Rc 11/4 4042 Rc 11/2 4850 Rc 2 4850 +/5 VP3145-OMM0003 VP31 5 3 / ( ) 30 1 ( ) 6 VP3145-OMM0003 VP31 5 3 / DIN DIN 1. 3. 1) 2) 2a 2b 3) 3a 4) 1) ( ) 2) 3) 2a 2b 0.5Nm20% 90
(A)(B) (A)(B) Rc 1/8 4 2 4 2 (kg) 0.83 5 1 3 5 1 3 (mm2) PA 44 38 32 (EA)(P)(EB) (EA)(P)(EB) (A)(B) (A)(B) P1=0.7MPa,P2=0.5MPaS PB 38 40 31 4 2 4 2 (mm2) AEA 90 5 1 3 5 1 3 P2=0.5MPaS BEB 77 (EA)(P)(EB) (EA)(P)(EB) ()( ) 2.8N m 7 VFR3000-OMY0001 VFRA3000,4000 3 VFRA3000 VFRA4000 3 1(P) 8 VFR3000-OMY0001 R , 9 VFR3000-OMY0001 No. 1ISO VG 32 R (1) (2) (3) (4) (5) (6) 10 VFR3000
After it comes into contact with the gasket of the coaxial cable pedestal, continue to tighten it by 90 degrees clockwise. * To ensure IP67 water and dust Included M2.6 x 8 screw: x 2 Recommended torque 0.9+/-10%Nm resistance Bracket Coaxial cable 2 x M4 Recommended torque 1.3+/-10%Nm -59No.EX-OMZ0016-C Attach the male connector of the coaxial cable to the antenna connector of the wireless
Available in 32 and 40mm bores with strokes from 5 to 100mm; rotation from 90 to 180 . Connection ports are available on both sides of the cylinder, as well as end-of-stroke sensing for all positions., Cylinder, Rotary, ROTARY ACTUATOR, D31, 1948.00000 lb
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D35, 2126.00000 lb
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D33, 2000.00000 lb
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D35, 1816.00000 lb
consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly with the circulating fluid which results in reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90
consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly with the circulating fluid which results in reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90
consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly with the circulating fluid which results in reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D35, 931.00000 lb
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D35, 2296.00000 lb
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D35, 1526.00000 lb
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D35, 286.00000 lb
Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D35, 2416.00000 lb
Double vane type is standardized for 90 and 100 degrees.Two shaft options available, Port locations modified, RoHS compliant, Mounting position of the auto switch can be set freely, Actuator, Rotary, Vane Type, ROTARY ACTUATOR, 519, 393.00000 lb
consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly with the circulating fluid which results in reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90
consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly with the circulating fluid which results in reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90
With the release of the KN series nozzles and gauge heads 30~90% of air consumption required for the current nozzle operation can be saved with the appropriate selection of the new nozzle and sizing. Many variations of nozzle are available with tube materials including nylon, soft nylon, soft copper pipe and OST tubing.