SMC Corporation of America
Elite Part Number Search
Search Results "PF2D301-A-M"

Note 2) 5 m elements use fiber type element which filtrate 5 m. Note 3) The element for 40 m uses a resin mesh with openings of 40 m in height and width. Note 4) The element for 80 m uses a resin mesh with openings of 80 m in height and width. Note 5) The amount of processed air when the initial pressure loss is 4 kPa.

Bracket B Line filter Mist separator Micro mist separator Bracket A Mounting screws Specific Product Precautions Bracket mounting view 14 AFF/AM/AMD Series Dimensions AFF/AM/AMD20 AFF/AM/AMD30 AFF/AM/AMD40 M D J U J D M S U N T S N T 2 x P (Port size) 2 x P (Port size) R Q Q R V C V C B G IN OUT IN OUT B G Maintenance space A Maintenance space E A AFF/AM/AMD50 AFF/AM/AMD60 J M D N T U S 2

Note 2) The water resistant 2-color solid state switch uses a 3 m lead wire as standard. (0.5 m is not available.) Note 3) For solid state with flexible wire specification, add "-61" after the lead wire length.

) L2 a = 2000 200 a = 3000 100 Mer m 3 0 1 2 Transfer load m (kg) a = 1000 a 2000 a = 2000 Mey L3 (mm) a = 3000 m 1000 L3 3 0 2 1 Transfer load m (kg) Refer to page 304 for deflection data. 210 5 Phase Stepper Motor/Without Motor Brake Series LXF Dimensions/LXFH5BC Scale: 35% (5) 2-M2.5 x 0.45 depth 2 5 Stroke + 113 10.5 2.5 2-M4 x 0.7 thread depth 9 31 G 28 58 5H9 +0.030 0 depth 5 (5.5)

Reference formulas [Dynamic moment at impact] Use the following formulas to calculate dynamic moment when taking stopper impact into consideration. m : Load weight (kg) F : Load (N) FE : Load equivalent to impact (at impact with stopper) (N) a : Average speed (mm/s) M : Static moment (Nm) = 1.4a (mm/s) FE = 1.4a x x m g : Impact speed (mm/s) L1 : Distance to the loads center of gravity

ZQ-OM01301-A Vacuum pump system Model of a single unit ZQ000 U A-K15L B-EA M G-3 3-N (1) (2) (3)(4) (5) (6) (7) (8)(9)(10) (1) Body type (6) Vacuum pressure switch unit specifications U For single unit Nil Note 4) With unit selection function M For manifold M Fixed SI unit (kPa) P Note 4) With unit selection function (2) Solenoid valve combination (Initial value: psi) K1 Supply valve (N.C

Free mount type Bearing type A High precision type Without auto switch 20 90 S M SUA 20 90 S D SUA L T79 M With auto switch Number of auto switches S Nil 1 pc. With auto switch (Built-in magnet) 2 pcs. S (1 auto switch) is shipped with a righthand auto switch. Nil (2 auto switches) is shipped with a right-hand and a left-hand switch.

a 2 port solenoid valve is connected to the right: When 2 air catch sensors are connected or when a 2 port solenoid valve is connected to the left: Joint bracket ISA-3-A Lead wire with connector (Individual wiring type) ISA-8-A ISA-8-B Bracket ISA-4-A DIN rail mounting bracket ISA-9-A Straight, 5 m A pair consists 1 set.

max Model CYV15 1 CYV32 5 (Nm) M1 M2 Model CYV15 CYV32 M1 0.3 3 M2 0.6 4 M3 0.3 3 m m Static Moment Moment generated by the work piece weight even when the cylinder is stopped Pitch moment M1 = m x g x (L + B) x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYV15 CYV32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m: Load mass

Standard 7 in. (0.18 m) 5 in. (0.13 m) 3) Not available with SH material.

Mount the switch in a location where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. With a switch with orifice, the adjusted flow rate value could be affected by vibration. 3. Do not use in an area where surges are generated.

This produces an air cushion cylinder which retains the merits of a compact design. Operating principle A + A' A' qWhen the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A. wAfter piston seal H has passed the air passage A, exhaust is discharged only from A'.

I IP address A 32 bit digit sequence which is assigned to identify devices which are connected to the network. MAC address A unique number inherent to all devices which are connected to PROFINET. M Manifold A form consisting of multiple components. A form made by combining multiple components. NPN input Takes the sensor output that uses the NPN transistor to the signal output line.

Extend the dimensions of A and H, when using a single/double knuckle joint together with a rod end nut.

Output unit How to Order EX510-FC 10 10.16 0.40 Cable length (L) 01 02 05 10 20 60 1 m 2 m 5 m 10 m 20 m 60 m Brown: +24 V Black: Communications + White: Communications Blue: 0 V L Note) (Reference: AWG18) Note) Branch cable length is a maximum of 20 m. Use the cable by cutting it into lengths of 20 m or shorter. w Branch connector (Unit 1 pc.)

Specified layout Note 2) (Available up to 32 solenoids) 20 20 stations Symbol A, B port P , E port A, B port size (Metric) Symbol A, B port P , E port A, B port size (Inch) Applicable series Applicable series C3 C4 C6 C4 C6 C8 C6 C8 C10 M N1 N3 N7 N3 N7 N9 N7 N9 N11 M 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting

Note 2) The figure shows an extended piston rod. 10-9-10 10 Heavy Duty Stopper Cylinder Series RSH/RS1H Proper Auto Switch Mounting Position Auto switch B A RE A B REC CX CY Proper Auto Switch Mounting Position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models MQQ M D-Y69 D-Y7PV D-Y7WV D-Y7BAL RHC Bore size (mm) A B A B A B MK(2) 20 8(6.5) 18 18 9.5 18 2 32 10.5(9) 13.5 13.5 12 13.5 4.5 RS

900 0.3 MK(2) 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 RS Q G 600 600 0 500 100 200 300 400 RS H A 63 Lateral load F [N] 500 500 50 400 400 RZQ RS1H50, 63, 80 300 300 1.0 RS1H80 MI W S RS1H50 200 200 RS1H63 0.9 Operating pressure P [MPa] 0.8 100 100 CEP1 0.7 10 20 30 40 10 20 30 40 0 0 0.6 CE1 Transfer speed [m/min] =

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Besides the models in the above table, there are some other auto switches that are applicable.

A C B ) M-01AN-4 M-01AN-6 M-01AU-4 M-01AU-6 5 7 5 7 16 18 16 18 2.1 4.0 2.1 4.0 1.8 2.5 1.8 2.5 Nylon tube Soft tube Hose nipple: M-01H-4, -6 Effective orifice(mm2 Weight (g) ) Part No.