Auto switch mounting Auto switch model C85 Series C75 Series Bore size [mm] 8 10 12 16 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V)*7 BJ6-008 (A set of a, b, c, d) BJ6-010 (A set of a, b, c, d) BJ6-012 (A set of a, b, c, d) BJ6-016 (A set of a, b, c, d) BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9lA(V) BJ6-008S (A
M-5AU-4 U6 For 6 soft tubing M-5AU-6 B Model 29 A B Vacuum inlet direction q Pad dia.
Allowable Moment (Nm) Allowable static moment Allowable dynamic moment 15.7 7.84 Pitching Yawing LXS Model Load movement direction 1000 m : Transfer load (kg) L : Overhang to work piece center of gravity (mm) a : Work piece acceleration (mm/sec) Me: Dynamic moment L1 (mm) L3 (mm) a = 1000 to 3000 Pitching a m 500 Mep L1 5 9 0 Transfer load m (kg) 1000 a = 1000 to 3000 Yawing 500 m Mey a L3
Mep 2000 a = 1000 L1 (mm) Pitching m : Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) m a = 2000 1000 L1 a = 3000 0 2 4 6 8 10 Transfer load m (kg) 600 L2 400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 L3 (mm) 2000 L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer
Pin arrangement 4 3 3 Cable length Connector model S M L A B D 0.5 m 1.0 m 3.0 m M8-3 pin M8-4 pin M12-4 pin Note) L is available for the D-P4DW type only. Note) Type D is available for the D-P4DW type only.
Pressure Control Equipment Industrial Filters A !4 Spring return !5 !6 !4 Spring extend A A-A section (port on rod end) A-A section (port on rod end) With auto switch Spring return Spring extend !4 !5 !6 !4 A A Auto Switch Auto Switch A-A section (port on rod end) A-A section (port on rod end) The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205).
Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Cable length Connector model Impact resistance 300 m/s2 S M L A B D 0.5 m 1.0 m 3.0 m M83 pin M84 pin M124 pin Enclosure IP-67 (IEC529 standard) Insulation resistance 100 M or more at 500 M VDC Note) Type D is available for the D-P5DW type only. Note) L is available for the D-P5DW type only.
Note 2) Model MGPL (Ball bushing bearing) cannot be used as a stopper. 1 20 30 40 50 5 10 Transfer speed: (m/min) Bore Size: 32 to 100/MGPM32 to 100 (Slide bearing) MGPM32 to 100 (Slide bearing) m m 2000 l 50 mm l 50 mm 100 1000 80 Weight of transferred object: m (kg) 63 500 400 50 300 40 200 When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently
AXT100-FC26-2: 3 m AXT100-FC26-3: 5 m DIN rail clamp screw EXH R EXH R B B B B B B B B P X X P 49 31.6 24.5 9.5 16 A A A A A A A A (7.5) (12) C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting P = 16 41 23 C10 [1(P) SUP port] C10: 10 One-touch fitting 2 L n Dimensions Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 24 stations) 3
AXT100-FC26-2: 3 m AXT100-FC26-3: 5 m DIN rail clamp screw EXH R EXH R B B B B B B B B P X X P 49 31.6 24.5 9.5 16 A A A A A A A A (7.5) (12) C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting P = 16 41 23 C10 [1(P) SUP port] C10: 10 One-touch fitting 2 L n Dimensions Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 24 stations) 3
Mep a = 1000 2000 L1 (mm) Pitching m : Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) m a = 2000 1000 L1 a = 3000 0 10 20 30 Transfer load m (kg) 600 L2 400 Mer L2 (mm) L3 (mm) m Rolling Yawing 200 L2 Mer 0 10 20 30 m Transfer load m (kg) 2000 a = 1000 L3 1000 a = 2000 m a = 3000 Mey a 0 10 20 30 Transfer load m (
Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Cable length Connector model Impact resistance 300 m/s2 S M L A B D 0.5 m 1.0 m 3.0 m M83 pin M84 pin M124 pin Enclosure IP-67 (IEC529 standard) Insulation resistance 100 M or more at 500 M VDC Note) Type D is available for the D-P5DW type only. Note) L is available for the D-P5DW type only.
Low Speed Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) MQ BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) RHC D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b,
a = 2000 L1 (mm) Pitching Mep m : Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) a = 3000 2000 m L1 0 10 20 30 Transfer load m (kg) L2 600 400 L2 (mm) Mer Rolling Yawing m 200 L2 Mer 10 20 30 0 Transfer load m (kg) m a = 1000 4000 a = 2000 L3 (mm) a = 3000 L3 2000 m Mey a 10 20 30 0 Transfer load m (kg) Refer to
Applicable pad 4020W/5020W/6020W/8020W Applicable pad 3507W/4010W/5010W/6010W Applicable pad 4030W/5030W/6030W/8030W A-A A-A A-A (5) (5) (5) 14.8 8.8 6 1.5 A A A A A A 2 0.8 2 3.5 4 4 15 15 30 3 5 5 3 5 3 0.8 0.8 8.4 12.8 20.4 Note) R part has to be smooth with no corners.
Fig. a 50 40 30 20 m Work load m [kg] m LEYG25M 10 5 4 3 2 Fig. b 1 50 40 20 30 10 5 Transfer speed [m/min] 865 LEYG Series Motorless Type * These graphs show the work load when the external guide is used together. When using the LEYG alone, refer to pages 864 and 865. * The values shown below are allowable values of the actuator body.
Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Cable length Connector model Impact resistance 300 m/s2 S M L A B D 0.5 m 1.0 m 3.0 m M83 pin M84 pin M124 pin Enclosure IP-67 (IEC529 standard) Insulation resistance 100 M or more at 500 M VDC Note) Type D is available for the D-P5DW type only. Note) L is available for the D-P5DW type only.
Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Cable length Connector model Impact resistance 300 m/s2 S M L A B D 0.5 m 1.0 m 3.0 m M83 pin M84 pin M124 pin Enclosure IP-67 (IEC529 standard) Insulation resistance 100 M or more at 500 M VDC Note) Type D is available for the D-P5DW type only. Note) L is available for the D-P5DW type only.
Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Cable length Connector model Impact resistance 300 m/s2 S M L A B D 0.5 m 1.0 m 3.0 m M83 pin M84 pin M124 pin Enclosure IP-67 (IEC529 standard) Insulation resistance 100 M or more at 500 M VDC Note) Type D is available for the D-P5DW type only. Note) L is available for the D-P5DW type only.
The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10). Output (OUT1) Indicator DOWN Button ( Button) Lights up when OUT1 is ON. UP Button ( Button) Use when decreasing a setting value. Use when increasing a setting value. MODE Button ( Button) SET Button ( Button) Use when changing a function. Use when selecting a function.