Part Number Description: MAINTENANCE KIT Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 120 Family Description: IR PRECISION REGULATOR Class Code: 21 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
Part Number Description: REPAIR KIT (80-IR200/201/202) Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 120 Family Description: IR PRECISION REGULATOR Class Code: 21 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
1220 (1.5)150 (1.0)23~140 F (-5 ~ 60 C)7-120 (0.05~0.83)ADC, AC2A-FADCADC, AC2A-FZDC, AC2A-F2.43 (1.1)B25PK50A-MP1.0-N02M (0~160 psig) Std. NAR O 25K50A-MP2.0-N02M (0~30 psig) Std. NAR O 35
1 1/2220 (1.5)150 (1.0)23~140 F (-5 ~ 60 C)7-120 (0.05~0.83)AC2A-FADCAC2A-FAC2A-F5.51 (2.5)?K50A-MP1.0-N02M (0~160 psig) Std. NAR O 25K50A-MP2.0-N02M (0~30 psig) Std. NAR O 35
Sensor -2kPa 0 2kPa 5kPa 10kPa Pressure range For low differential pressure PSE550 0 2kPa -0.2kPa 2kPa Rated differential pressure range of sensor Set differential pressure range of controller 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved 1st printing July, 2003 D-YGA P-120 (YGA)
N Bracket dimensions With auto-drain Model Port size A B C D E F G H J K L M U (Body) V (Adapter) L 178 211 277 321 B 260 298 366 436 T 9 9 11 11 S 8 16 21 26 R 78 97 98 115 P 50 35 45 46.5 1/4, 3/8 1/4, 3/8, 1/2 1/2, 3/4 3/4, 1 1/4, 3/8 1/4, 3/8, 1/2 1/2, 3/4 3/4, 1 AMR3000 AMR4000 AMR5000 AMR6000 100 120 130 160 180 210 246 290 264 302 370 440 10 10 45 70 101 121 131 161 51 61 66 81 28
Externally set input impedance 100 k or more Externally set input voltage 0 to 5 V 1 8 External potentiometer 10 k ( W or more): not provided Step response 0.06 s or less (1 A, 95%) Dither frequency adjustable range (DITHER) 120 to 180 Hz (140 Hz when delivered) 0 to 500 mA (0 mA when delivered) Zero adjustable range (NULL) 500 mA to 1 A for input voltage 5 V (1 A when delivered) Gain adjustable
Printed in Japan. 1st printing April, 2003 D-DN P-120 (DN) Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.
Solenoid Valve Dimensions Plug lead unit manifold (VV2Q32) VX VNl VQ Equation L1= (n1) X 37+56 L2=L110 L3=L410.5 L5=L111.2 Dotted line: DIN rail mounting (-D) Dimensions n: Station (Max. 20) L n 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 389 759 352 722 315 685 278 648 L1 L2 L3 L4 L5 241 611 204 574 167 537 130 500 93 463 56 426 379 749 342 712 305 675 268 638 231 601 194 564 157 527 120
For subsonic range Where P1 + 0.1013 = (1 to 2) (P2 + 0.1013) Formula based on Cv factor Q = 197.8Cv P (P2 + 0.1013) kg/h Formula based on effective area Q = 11.0S P (P2 + 0.1013) kg/h [650] (133) 0.2 [646] (120) 0.1 S = 2.8mm S = 5.9mm S = 9.2mm S = 11.7mm S = 6.3mm S = 9.7mm S = 14.4mm S = 10.8mm S = 15.3mm S = 24.8mm Flow rate Q kg/h VCS212 VCS213 VCS214 VCS215 VCS 13 VCS314 VCS315
0.15) 2 3 3 (R) 1 (P) Note 1) M5 x 0.8 Rc(PT) 1/8 Body ported VKF33 E (for long loading time) 2.7 (0.15) 80 2 3 VKF33 V (for vacuum) 3.6 (0.2) 2 3 101.2kPa to 0.1 {1Torr to 1} VKF33 W (for low power consumption/vacuum) 2.7 (0.15) 2 3 VKF334 4.5 (0.25) 0 to 0.7 {0 to 7.1} VKF334Y (for low power consumption, DC2W) 2.7 (0.15) Base mounted VKF334E (for long loading time) Rc(PT) 1/8 2.7 (0.15) 120
Flow Rate and Effective Area VR1211F Model 6 4 3.2 Metric size Applicable tubing O.D. 1/4" 5/32" 1/8" Inch size 170 (6.0) 150 (5.3) 120 (4.2) 100 (3.5) Flow rate l/min ANR (SCFM) INOUT 2.6 (0.14) 2.3 (0.13) 1.8 (0.1) 1.5 (0.08) Effective area mm (Cv) Note 1) Flow rate values are at a pressure of 0.5MPa (72 psi) and temperature of 20C (68F).
Compact size and lightweight (120 g with complete unit); well suitable for actuator mounting Ejector nozzle size: 0.5 to 1.0 (Suction flow: 5 to 22 l/min (ANR)) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ejector system Ejector system Vacuum switch unit Filter
o 0.62 322 1.28 14 oaa {4) 250 u-24 0.50 .621 .621 0.25 0.93 0.38 1t-1E .251 .250 0.75 0.25 0.34 0.75 o.75 o.1a cts16 0.75 120 o.62 3.19 3.8:t 343 t06 {17-l _312 6t-21 0.50 .621 .621 0.38 1 . 1 2 0.38 5t-i E .25r .250 0.75 0.25 o.3a 3.97 o.8a o_aao.24 qi-14 o.75 1.30 0.62 334 1.25 125 t 2 5 t 1 k ) 375 \-24 o.aE .749 .749 o.11 r.32 0.50 .251 o.25 0.41 rt.4 1.06 r.06 0.25 sa-l6 0.46 r.62 0.78
q1 30 PSI (2.okgtcmr) Ambient and fluid temprature32-120"F (0-+50.C) Lubrication Not Pilot operator manual orenide Protection construction Non-locking push type {exlendedl, Lock type (screwl, Lock type (lever) 100Y soAaHz, 2OOV so/aoHz Valve Nonlocking push type (Flush) With indicator light and surge voltage Dust Proof ll(]Vs%oHz 220V5%a1l. 24U5%aqz uated voltage Ac Notel Operatrng pressure
NVKF332Y {Low watlaqe: 2WDC) NVKF332V {Vacuum) l Ton-100 PSI (-100 KPa-o.7 MPa) NVKF332W tLow wattaoe + Vacuuml 0.181 lbs (80 s0 NVKF333 0-100 PSI {0-0.7 MPa) NVKF333Y ilow waltaqe: 2WDC) NVKF333V (Vacuum) 1 Torr"100 PSI (-100 KPa-0.7 MPa) NVKF333W ilow wattaoe + Vacuuml 2 position srngre solenoid (for maniiold) 0r5 NVKF334 0 ' 1 0 0 P S I (0-0.7 MPa) o.25 n 1 < 1/8 NPTF u.zt ir5 0.271 lbs (120
NVFR3000, plug-in and non plug-in types, Maximum operating pressure: 130 PSI, Ambient and fluid temperature: 32 120 F, Manual override: non locking push style, VALVE, DBL SOL *LQA, VALVE, VFR3000 SOL VALVE 4/5 PORT, 2E, VFR3000, 1.07800 lb
Part Number Description: ADJUST KNOB IR1000 Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 120 Family Description: IR PRECISION REGULATOR Class Code: 21 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
NVFR4000, plug-in and non plug-in types, Maximum operating pressure: 130 PSI, Ambient and fluid temperature: 32 120 F, Manual override: non locking push style, VALVE SOL/PILOT 24VDC *LQA, VALVE, VFR4000 SOL VALVE 4/5 PORT, 2E, VFR4000, 1.60600 lb
See individual series information for replacements. 5 port solenoid valve, North American - old style see replacement series SYJ5000 - New Style , Operating pressure range: 20-100 PSI (2 pos sgl/3 pos.) 15-100 PSI (2 position double) , Response time (70PSI): 20ms (2 pos. sgl/dbl) 35ms (3 position) , Ambient and fluid temperature: Max. 120 F (50 C) , Lubrication: non-lube, VALVE, SOL.